    keyword=End_of_Run_22198
    ****************************
     Run Number: 22198
     End of Run Comment:
    Run_type=Test,target_type=4He 10cm Loop1 High Pressure,beam_e0=2.839,beam_raster=on,beam_halfwaveplate=out,leftarm_p=2.22892,leftarm_theta=15,leftarm_colli=out,rightarm_p=2.791,rightarm_theta=15,rightarm_colli=out,comment_text=He loop1
     
    
    PRESCALE FACTORS:ps1=14   ps2=250   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 1023081      
    TIME     : 4.665 mins  
    
    DEAD TIME:   3.18%      
    
    TRIGGER RATES:   PRES/REAL
    T1:3754.3/52559.8 Hz   T2:21.1/5286.2 Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:1050774/14710847  T2:   5918/1479532  T8:      4/286605   
    
    AVERAGE CURRENT
    BCM x1 : 70.4037uA  BCM x3 : 70.3304uA  BCM x10: 23.9212uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.01978        BCM u3 : 0.01976        BCM u10: 0.0006582      
    
    BCM d1 : 0.01963        BCM d3 : 0.01961        BCM d10: 0.01273        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 22198 at Wed Dec 19 20:00:29 EST 2007
    
    Wien angle : 6.19568
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 2.79106
    Left Arm arm angle : 14.9991
    Right Arm D1 momentum : 2.791
    Right Arm arm angle : 15.001
    HALLA:p : 2845.34
    HALLA:dpp : -0.000110223
    Tiefenbach Hall A energy : 2845.34
    Left Arm Top VDC Current : -9.47266
    Left Arm Bottom VDC Current : -1.5625
    Left Arm Q1 momentum : 2.79097
    Left Arm Q1 power supply : 2099.73
    Left Arm Q1 gauss meter : -0.17713
    Left Arm Q2 gauss meter : 0.6318
    Left Arm Q2 power supply current : 1201.94
    Left Arm Q2 momentum : 2.79132
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 969.034
    Left Arm D1 momentum : 2.79106
    Left Arm D1 NMR : 1.03331
    Left Arm Q3 gauss meter : -0.5624
    Left Arm Q3 power supply current : 1110.88
    Left Arm Q3 momentum : 2.79032
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 2.79045
    Right Arm Q1 power supply : 2098.24
    Right Arm Q1 gauss meter : -0.05234
    Right Arm Q2 power supply current : 1201.27
    Right Arm Q2 momentum : 2.79126
    Right Arm Q2 gauss meter : 0.6285
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 994.541
    Right Arm D1 momentum : 2.791
    Right Arm D1 NMR : 1.03571
    Right Arm Q3 power supply current : 1110.41
    Right Arm Q3 momentum : 2.79061
    Right Arm Q3 gauss meter : 0.4968
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 70.3382
    Current on Unser monitor : 81.4806
    Current on Upstream bcm : 70.1629
    Current on Downstream bcm : 70.5135
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 110.191
    Hall C Current : 39.81
    MBSY1c magnet current (amp) : 118.639
    MBSY1c Bdl : 711246
    Hall A momentum (Tiefenbach) (HALLA:p) : 2845.34
    Hall A momentum orbit correction (dpp) : -0.000110206
    Hall A setup momentum (MMSHLAE) : 2839.38
    Hall A energy (halla_MeV) : 2845.34
    Hall C energy (hallc_MeV) : 3549.62
    Delta(E)/E width (MV_AI_DXWID) : 1.63814
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : -1.95837
    IPM1H04A.YPOS : 0.0369715
    IPM1H04B.XPOS : -1.99319
    IPM1H04B.YPOS : -0.0235301
    Left Arm Collimator : 0.871338
    HacL_HPE1313A:0_Ch58 : -0.189941
    HacL_HPE1313A:0_Ch55 : 23.1445
    HacL_HPE1313A:0_Ch54 : 0.00537109
    -----
    SLI data valid? : Yes
    SLI horiz size mm : 0.272122
    SLI Energy spread *10^5 : 5.0393
    SLI x position : 1.58012
    SLI vert. size mm : 0.0918319
    SLI y position : 1.51737
    -----
    Target : L1 10cm
    Vacuum Pressure : 4.27149e-07
    fan frequency loop 1 : 59.5
    fan frequency loop 3 : 59.5
    Encoder position : 3.30403e+07
    Target type : 3.30403e+07
    temperature loop 1(1) : 7
    temperature loop 1(3) : 7.16
    Heat exchange He : 7.5
    temperature loop 3(1) : 18.85
    temperature loop 3(3) : 19
    Heat exchange H2 : 18.5
    HPH He loop 1 : 19.2389
    HPH H2 loop 3 : 192.338