Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 20:35:41 on December 19, 2007

    Entry number 222288

    keyword=End_of_Run_4343
    ****************************
     Run Number: 4343
     End of Run Comment:
    Run_type=Test,target_type=LH2 15cm + Pb foil Loop3,beam_e0=2.839,beam_raster=on,leftarm_p=2.22892,leftarm_theta=15,leftarm_colli=out,rightarm_p=2.791,rightarm_theta=15,rightarm_colli=out,comment_text=LH2 loop3 raster check
     
    
    PRESCALE FACTORS:ps1=16777212   ps2=16777215   ps3=12   ps4=9   ps5=65535   ps6=65535   ps7=9999   ps8=65535   
    
    EVENTS   : 1179431      
    TIME     : 5.301 mins  
    
    DEAD TIME:   4.67%      
    
    TRIGGER RATES:   PRES/REAL
    T3:3867.3/46407.2 Hz   T4:22.6/203.5 Hz   T5: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T3:1230062/14760748  T4:   7190/64716    T5:      0/0        T8:      4/325704   
    
    AVERAGE CURRENT
    BCM x1 : 4.7332 uA  BCM x3 : 4.7383 uA  BCM x10: 4.7781 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.001509       BCM u3 : 0.00151        BCM u10: 0.001521       
    
    BCM d1 : 0.001502       BCM d3 : 0.001505       BCM d10: 0.001518       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4343 at Wed Dec 19 20:35:37 EST 2007
    
    Wien angle : 6.19568
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 2.57295
    Left Arm arm angle : 14.9991
    Right Arm D1 momentum : 2.52484
    Right Arm arm angle : 15.001
    HALLA:p : nan
    HALLA:dpp : nan
    Tiefenbach Hall A energy : nan
    Left Arm Top VDC Current : 1.61133
    Left Arm Bottom VDC Current : -5.12695
    Left Arm Q1 momentum : 2.57282
    Left Arm Q1 power supply : 1935.61
    Left Arm Q1 gauss meter : -0.16336
    Left Arm Q2 gauss meter : 0.5825
    Left Arm Q2 power supply current : 1107.7
    Left Arm Q2 momentum : 2.57244
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 886.184
    Left Arm D1 momentum : 2.57295
    Left Arm D1 NMR : 0.952378
    Left Arm Q3 gauss meter : -0.5188
    Left Arm Q3 power supply current : 1024.49
    Left Arm Q3 momentum : 2.57333
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 2.57269
    Right Arm Q1 power supply : 1934.49
    Right Arm Q1 gauss meter : -0.04831
    Right Arm Q2 power supply current : 1107.59
    Right Arm Q2 momentum : 2.57358
    Right Arm Q2 gauss meter : 0.5796
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 883.626
    Right Arm D1 momentum : 2.52484
    Right Arm D1 NMR : 0.936958
    Right Arm Q3 power supply current : 1023.68
    Right Arm Q3 momentum : 2.57265
    Right Arm Q3 gauss meter : 0.458
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 4.9773
    Current on Unser monitor : 17.7917
    Current on Upstream bcm : 4.97024
    Current on Downstream bcm : 4.96029
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 44.9466
    Hall C Current : 40.14
    MBSY1c magnet current (amp) : 118.639
    MBSY1c Bdl : 711246
    Hall A momentum (Tiefenbach) (HALLA:p) : nan
    Hall A momentum orbit correction (dpp) : nan
    Hall A setup momentum (MMSHLAE) : 2839.38
    Hall A energy (halla_MeV) : nan
    Hall C energy (hallc_MeV) : 3549.74
    Delta(E)/E width (MV_AI_DXWID) : 1.6423
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : -1.93462
    IPM1H04A.YPOS : 0.0192977
    IPM1H04B.XPOS : -1.95102
    IPM1H04B.YPOS : -0.00767839
    Left Arm Collimator : 0.871436
    HacL_HPE1313A:0_Ch58 : -0.189453
    HacL_HPE1313A:0_Ch55 : 23.0957
    HacL_HPE1313A:0_Ch54 : 0.00634766
    SLI data valid? : Yes
    SLI horiz size mm : 0.203265
    SLI Energy spread *10^5 : 3.76417
    SLI x position : 1.58012
    SLI vert. size mm : 0.0664475
    SLI y position : 1.51737
    -----
    Target : L3 15cm
    fan frequency loop 1 : 59.5
    fan frequency loop 3 : 59.5
    Encoder position : 1.63491e+07
    Target type : 1.63491e+07
    temperature loop 1(1) : 7
    temperature loop 1(3) : 7.05
    Heat exchange He : 7.4
    temperature loop 3(1) : 18.83
    temperature loop 3(3) : 19
    Heat exchange H2 : 18.5
    HPH He loop 1 : 113.797
    HPH He loop 2 : 8.33054
    HPH H2 loop 3 : 460.21
    -----