     Run Number: 4346
     End of Run Comment:
    Run_type=Optics,target_type=Optics,beam_e0=2.839,beam_raster=on,leftarm_p=2.57,leftarm_theta=15,leftarm_colli=out,rightarm_p=2.57,rightarm_theta=15,rightarm_colli=out,comment_text=Optics test
     
    
    PRESCALE FACTORS:ps1=16777212   ps2=16777215   ps3=6   ps4=3   ps5=65535   ps6=65535   ps7=9999   ps8=65535   
    
    EVENTS   : 634267       
    TIME     : 4.835 mins  
    
    DEAD TIME:   3.33%      
    
    TRIGGER RATES:   PRES/REAL
    T3:2235.8/13414.7 Hz   T4:26.2/78.6 Hz   T5: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T3: 648542/3891254  T4:   7599/22797    T5:      0/0        T8:      4/297035   
    
    AVERAGE CURRENT
    BCM x1 : 9.4250 uA  BCM x3 : 9.4316 uA  BCM x10: 9.5096 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.00274        BCM u3 : 0.002741       BCM u10: 0.002761       
    
    BCM d1 : 0.002728       BCM d3 : 0.002731       BCM d10: 0.002756       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4346 at Wed Dec 19 21:10:40 EST 2007
    
    Wien angle : 6.19568
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 2.57295
    Left Arm arm angle : 14.9991
    Right Arm D1 momentum : 2.57248
    Right Arm arm angle : 15.001
    HALLA:p : 2845.54
    HALLA:dpp : -4.05951e-05
    Tiefenbach Hall A energy : 2845.54
    Left Arm Top VDC Current : 4.10156
    Left Arm Bottom VDC Current : 2.19727
    Left Arm Q1 momentum : 2.57282
    Left Arm Q1 power supply : 1935.61
    Left Arm Q1 gauss meter : -0.16335
    Left Arm Q2 gauss meter : 0.5824
    Left Arm Q2 power supply current : 1107.7
    Left Arm Q2 momentum : 2.57247
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 886.184
    Left Arm D1 momentum : 2.57295
    Left Arm D1 NMR : 0.952379
    Left Arm Q3 gauss meter : -0.5186
    Left Arm Q3 power supply current : 1024.25
    Left Arm Q3 momentum : 2.57272
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 2.57262
    Right Arm Q1 power supply : 1934.44
    Right Arm Q1 gauss meter : -0.04832
    Right Arm Q2 power supply current : 1107.59
    Right Arm Q2 momentum : 2.57359
    Right Arm Q2 gauss meter : 0.5796
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 909.583
    Right Arm D1 momentum : 2.57248
    Right Arm D1 NMR : 0.954617
    Right Arm Q3 power supply current : 1023.68
    Right Arm Q3 momentum : 2.57266
    Right Arm Q3 gauss meter : 0.4581
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 10.0989
    Current on Unser monitor : 22.4339
    Current on Upstream bcm : 10.1159
    Current on Downstream bcm : 10.0818
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 79.4322
    Hall C Current : 69.48
    MBSY1c magnet current (amp) : 118.639
    MBSY1c Bdl : 711246
    Hall A momentum (Tiefenbach) (HALLA:p) : 2845.53
    Hall A momentum orbit correction (dpp) : -4.54435e-05
    Hall A setup momentum (MMSHLAE) : 2839.38
    Hall A energy (halla_MeV) : 2845.53
    Hall C energy (hallc_MeV) : 3549.65
    Delta(E)/E width (MV_AI_DXWID) : 1.67249
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : -1.98513
    IPM1H04A.YPOS : 0.0514147
    IPM1H04B.XPOS : -2.00521
    IPM1H04B.YPOS : 0.0154476
    Left Arm Collimator : 0.871484
    HacL_HPE1313A:0_Ch58 : -0.189453
    HacL_HPE1313A:0_Ch55 : 23.1445
    HacL_HPE1313A:0_Ch54 : 0.00634766
    SLI data valid? : Yes
    SLI horiz size mm : 0.223398
    SLI Energy spread *10^5 : 4.137
    SLI x position : 1.59503
    SLI vert. size mm : 0.100792
    SLI y position : 1.51737
    -----
    Target : Optics
    fan frequency loop 1 : 59.5
    fan frequency loop 3 : 60
    Encoder position : 1.28675e+07
    Target type : 1.28675e+07
    temperature loop 1(1) : 7
    temperature loop 1(3) : 7.05
    Heat exchange He : 7.4
    temperature loop 3(1) : 18.84
    temperature loop 3(3) : 19
    Heat exchange H2 : 18.5
    HPH He loop 1 : 109.889
    HPH He loop 2 : 6.59009