Log entry time 21:23:44 on December 19, 2007
Entry number 222302
keyword=End_of_Run_4347
****************************
Run Number: 4347
End of Run Comment:
Run_type=Test,target_type=LH2 15cm Loop3,beam_e0=2.839,beam_raster=on,leftarm_p=2.57,leftarm_theta=15,leftarm_colli=out,rightarm_p=2.57,rightarm_theta=15,rightarm_colli=out,comment_text=LH2 loop3
PRESCALE FACTORS:ps1=16777212 ps2=16777215 ps3=12 ps4=9 ps5=65535 ps6=65535 ps7=9999 ps8=65535
EVENTS : 1980816
TIME : 8.595 mins
DEAD TIME: 4.44%
TRIGGER RATES: PRES/REAL
T3:3996.5/47957.7 Hz T4:23.0/207.0 Hz T5: 0.0/0.0 Hz T8: 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T3:2060931/24731177 T4: 11858/106722 T5: 0/0 T8: 8/528064
AVERAGE CURRENT
BCM x1 : 4.8910 uA BCM x3 : 4.8960 uA BCM x10: 4.9371 uA
APPROXIMATE BCM CHARGES (C)
BCM u1 : 0.002527 BCM u3 : 0.002529 BCM u10: 0.002548
BCM d1 : 0.002517 BCM d3 : 0.002521 BCM d10: 0.002544
****************************
End-of-run EPICS data for Run Number 4347 at Wed Dec 19 21:23:41 EST 2007
Wien angle : 6.19568
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 2.57295
Left Arm arm angle : 14.9991
Right Arm D1 momentum : 0
Right Arm arm angle : 0.197
HALLA:p : 2845.37
HALLA:dpp : -9.86998e-05
Tiefenbach Hall A energy : 2845.37
Left Arm Top VDC Current : -3.17383
Left Arm Bottom VDC Current : -2.44141
Left Arm Q1 momentum : 2.57289
Left Arm Q1 power supply : 1935.67
Left Arm Q1 gauss meter : -0.16336
Left Arm Q2 gauss meter : 0.5825
Left Arm Q2 power supply current : 1107.7
Left Arm Q2 momentum : 2.57246
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 886.184
Left Arm D1 momentum : 2.57295
Left Arm D1 NMR : 0.952379
Left Arm Q3 gauss meter : -0.5187
Left Arm Q3 power supply current : 1024.33
Left Arm Q3 momentum : 2.57292
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 2.57262
Right Arm Q1 power supply : 1934.44
Right Arm Q1 gauss meter : -0.04831
Right Arm Q2 power supply current : 1107.59
Right Arm Q2 momentum : 2.57359
Right Arm Q2 gauss meter : 0.5795
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 912.56
Right Arm D1 momentum : 0
Right Arm D1 NMR : 1.71268
Right Arm Q3 power supply current : 1023.68
Right Arm Q3 momentum : 2.57265
Right Arm Q3 gauss meter : 0.458
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 5.07039
Current on Unser monitor : 18.6044
Current on Upstream bcm : 5.06868
Current on Downstream bcm : 5.07211
Upstream Cavity Coefficient : 43.377
Downstream Cavity Coefficient : 42.913
Current on IBC0L02 (source) : 74.2159
Hall C Current : 68.73
MBSY1c magnet current (amp) : 118.639
MBSY1c Bdl : 711246
Hall A momentum (Tiefenbach) (HALLA:p) : 2845.37
Hall A momentum orbit correction (dpp) : -0.000100864
Hall A setup momentum (MMSHLAE) : 2839.38
Hall A energy (halla_MeV) : 2845.37
Hall C energy (hallc_MeV) : 3549.56
Delta(E)/E width (MV_AI_DXWID) : 1.68875
IPM1C12.XPOS : 0
IPM1H04A.XPOS : -1.98803
IPM1H04A.YPOS : 0.0433153
IPM1H04B.XPOS : -2.00037
IPM1H04B.YPOS : 0.0100184
Left Arm Collimator : 0.871436
HacL_HPE1313A:0_Ch58 : -0.189941
HacL_HPE1313A:0_Ch55 : 23.0957
HacL_HPE1313A:0_Ch54 : 0.00683594
SLI data valid? : Yes
SLI horiz size mm : 0.212841
SLI Energy spread *10^5 : 3.9415
SLI x position : 1.58012
SLI vert. size mm : 0.0243397
SLI y position : 1.51737
-----
Target : L3 15cm
fan frequency loop 1 : 59.5
fan frequency loop 3 : 60
Encoder position : 1.63491e+07
Target type : 1.63491e+07
temperature loop 1(1) : 7
temperature loop 1(3) : 7.05
Heat exchange He : 7.4
temperature loop 3(1) : 18.83
temperature loop 3(3) : 19
Heat exchange H2 : 18.5
HPH He loop 1 : 124.158
HPH He loop 2 : 7.23539
HPH H2 loop 3 : 461.306
-----