Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 01:35:51 on December 20, 2007

    Entry number 222323

    keyword=End_of_Run_4350
    ****************************
     Run Number: 4350
     End of Run Comment:
    Run_type=Optics,target_type=Optics,beam_e0=2.839,beam_raster=off,leftarm_p=2.815,leftarm_theta=15,leftarm_colli=out,rightarm_p=2.815,rightarm_theta=15,rightarm_colli=out,comment_text=
     
    
    PRESCALE FACTORS:ps1=16777212   ps2=16777215   ps3=9   ps4=15   ps5=65535   ps6=65535   ps7=9999   ps8=65535   
    
    EVENTS   : 1007272      
    TIME     : 16.055 mins  
    
    DEAD TIME:   1.10%      
    
    TRIGGER RATES:   PRES/REAL
    T3:1037.2/9334.6 Hz   T4:20.1/301.7 Hz   T5: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T3: 999130/8992178  T4:  19378/290678   T5:      0/0        T8:     15/986441   
    
    AVERAGE CURRENT
    BCM x1 : 63.0644uA  BCM x3 : 63.0130uA  BCM x10: 43.6186uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.06104        BCM u3 : 0.06101        BCM u10: 0.04305        
    
    BCM d1 : 0.06046        BCM d3 : 0.0604         BCM d10: 0.04099        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4350 at Thu Dec 20 01:35:47 EST 2007
    
    Wien angle : 6.19568
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 2.81455
    Left Arm arm angle : 14.9985
    Right Arm D1 momentum : 2.81633
    Right Arm arm angle : 15.0039
    HALLA:p : 2845.42
    HALLA:dpp : -8.25225e-05
    Tiefenbach Hall A energy : 2845.42
    Left Arm Top VDC Current : -3.51562
    Left Arm Bottom VDC Current : 0.976562
    Left Arm Q1 momentum : 2.81461
    Left Arm Q1 power supply : 2117.52
    Left Arm Q1 gauss meter : -0.17867
    Left Arm Q2 gauss meter : 0.637
    Left Arm Q2 power supply current : 1211.85
    Left Arm Q2 momentum : 2.81432
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 977.043
    Left Arm D1 momentum : 2.81455
    Left Arm D1 NMR : 1.04203
    Left Arm Q3 gauss meter : -0.5672
    Left Arm Q3 power supply current : 1120.42
    Left Arm Q3 momentum : 2.8143
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 2.81453
    Right Arm Q1 power supply : 2116.34
    Right Arm Q1 gauss meter : -0.05282
    Right Arm Q2 power supply current : 1211.33
    Right Arm Q2 momentum : 2.81465
    Right Arm Q2 gauss meter : 0.6337
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 1002.18
    Right Arm D1 momentum : 2.81627
    Right Arm D1 NMR : 1.04508
    Right Arm Q3 power supply current : 1120.15
    Right Arm Q3 momentum : 2.81508
    Right Arm Q3 gauss meter : 0.5012
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 70.2381
    Current on Unser monitor : 82.6962
    Current on Upstream bcm : 70.2445
    Current on Downstream bcm : 70.2317
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 114.669
    Hall C Current : 45.72
    MBSY1c magnet current (amp) : 118.639
    MBSY1c Bdl : 711246
    Hall A momentum (Tiefenbach) (HALLA:p) : 2845.41
    Hall A momentum orbit correction (dpp) : -8.47005e-05
    Hall A setup momentum (MMSHLAE) : 2839.38
    Hall A energy (halla_MeV) : 2845.41
    Hall C energy (hallc_MeV) : 3549.63
    Delta(E)/E width (MV_AI_DXWID) : 1.67053
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : -1.98479
    IPM1H04A.YPOS : 0.0554101
    IPM1H04B.XPOS : -1.99812
    IPM1H04B.YPOS : -0.00102794
    Left Arm Collimator : 0.871387
    HacL_HPE1313A:0_Ch58 : -0.189941
    HacL_HPE1313A:0_Ch55 : 22.998
    HacL_HPE1313A:0_Ch54 : 0.00585938
    SLI data valid? : Yes
    SLI horiz size mm : 0.290176
    SLI Energy spread *10^5 : 5.37363
    SLI x position : 1.58012
    SLI vert. size mm : 0.108513
    SLI y position : 1.50986
    -----
    Target : Optics
    fan frequency loop 1 : 60
    fan frequency loop 3 : 59.5
    Encoder position : 1.28675e+07
    Target type : 1.28675e+07
    temperature loop 1(1) : 7
    temperature loop 1(3) : 7.05
    Heat exchange He : 7.4
    temperature loop 3(1) : 18.84
    temperature loop 3(3) : 19
    Heat exchange H2 : 18.5
    HPH He loop 1 : 110.999
    HPH He loop 2 : 6.71674
    HPH H2 loop 3 : 467.911
    -----