    keyword=End_of_Run_22202
    ****************************
     Run Number: 22202
     End of Run Comment:
    Run_type=Optics,target_type=Optics,beam_e0=2.839,beam_raster=off,beam_halfwaveplate=out,leftarm_p=2.758,leftarm_theta=15,leftarm_colli=out,rightarm_p=2.815,rightarm_theta=15,rightarm_colli=out,comment_text=
     
    
    PRESCALE FACTORS:ps1=9   ps2=25   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 1003308      
    TIME     : 14.771 mins  
    
    DEAD TIME:   1.17%      
    
    TRIGGER RATES:   PRES/REAL
    T1:1119.0/10070.8 Hz   T2:26.4/660.8 Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1: 991712/8925415  T2:  23425/585648   T8:     13/907536   
    
    AVERAGE CURRENT
    BCM x1 : 70.0697uA  BCM x3 : 70.0042uA  BCM x10: 23.6097uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.06241        BCM u3 : 0.06235        BCM u10: 0.001028       
    
    BCM d1 : 0.06179        BCM d3 : 0.06174        BCM d10: 0.04082        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 22202 at Thu Dec 20 01:56:27 EST 2007
    
    Wien angle : 6.19568
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 2.75827
    Left Arm arm angle : 14.9985
    Right Arm D1 momentum : 2.81477
    Right Arm arm angle : 15.0039
    HALLA:p : 2845.4
    HALLA:dpp : -8.89644e-05
    Tiefenbach Hall A energy : 2845.4
    Left Arm Top VDC Current : 2.05078
    Left Arm Bottom VDC Current : 1.80664
    Left Arm Q1 momentum : 2.75824
    Left Arm Q1 power supply : 2075.11
    Left Arm Q1 gauss meter : -0.17512
    Left Arm Q2 gauss meter : 0.6246
    Left Arm Q2 power supply current : 1187.98
    Left Arm Q2 momentum : 2.7589
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 955.582
    Left Arm D1 momentum : 2.75827
    Left Arm D1 NMR : 1.02114
    Left Arm Q3 gauss meter : -0.5558
    Left Arm Q3 power supply current : 1098.01
    Left Arm Q3 momentum : 2.758
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 2.81453
    Right Arm Q1 power supply : 2116.34
    Right Arm Q1 gauss meter : -0.05281
    Right Arm Q2 power supply current : 1211.33
    Right Arm Q2 momentum : 2.81464
    Right Arm Q2 gauss meter : 0.6337
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 1003.47
    Right Arm D1 momentum : 2.81477
    Right Arm D1 NMR : 1.04453
    Right Arm Q3 power supply current : 1120.14
    Right Arm Q3 momentum : 2.81507
    Right Arm Q3 gauss meter : 0.5012
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 69.8264
    Current on Unser monitor : 81.2013
    Current on Upstream bcm : 69.9682
    Current on Downstream bcm : 69.6847
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 109.824
    Hall C Current : 39.78
    MBSY1c magnet current (amp) : 118.639
    MBSY1c Bdl : 711246
    Hall A momentum (Tiefenbach) (HALLA:p) : 2845.38
    Hall A momentum orbit correction (dpp) : -9.52967e-05
    Hall A setup momentum (MMSHLAE) : 2839.38
    Hall A energy (halla_MeV) : 2845.38
    Hall C energy (hallc_MeV) : 3549.64
    Delta(E)/E width (MV_AI_DXWID) : 1.60988
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : -1.98504
    IPM1H04A.YPOS : 0.0636073
    IPM1H04B.XPOS : -2.00107
    IPM1H04B.YPOS : 0.00725824
    Left Arm Collimator : 0.871436
    HacL_HPE1313A:0_Ch58 : -0.189453
    HacL_HPE1313A:0_Ch55 : 23.0957
    HacL_HPE1313A:0_Ch54 : 0.00634766
    -----
    SLI data valid? : Yes
    SLI horiz size mm : 0.287328
    SLI Energy spread *10^5 : 5.32089
    SLI x position : 1.58012
    SLI vert. size mm : 0.105606
    SLI y position : 1.50986
    -----
    Target : Optics
    Vacuum Pressure : 4.18826e-07
    fan frequency loop 1 : 60
    fan frequency loop 3 : 59.5
    Encoder position : 1.28675e+07
    Target type : 1.28675e+07
    temperature loop 1(1) : 7
    temperature loop 1(3) : 7.04
    Heat exchange He : 7.4
    temperature loop 3(1) : 18.84
    temperature loop 3(3) : 19.01
    Heat exchange H2 : 18.5
    HPH He loop 1 : 102.279
    HPH H2 loop 3 : 449.319