Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 01:57:09 on December 20, 2007

    Entry number 222329

    keyword=End_of_Run_4351
    ****************************
     Run Number: 4351
     End of Run Comment:
    Run_type=Optics,target_type=Optics,beam_e0=2.839,beam_raster=off,leftarm_p=2.758,leftarm_theta=15,leftarm_colli=out,rightarm_p=2.815,rightarm_theta=15,rightarm_colli=out,comment_text=
     
    
    PRESCALE FACTORS:ps1=16777212   ps2=16777215   ps3=22   ps4=22   ps5=65535   ps6=65535   ps7=9999   ps8=65535   
    
    EVENTS   : 1001454      
    TIME     : 14.020 mins  
    
    DEAD TIME:   1.06%      
    
    TRIGGER RATES:   PRES/REAL
    T3:1182.7/26018.5 Hz   T4:20.6/453.0 Hz   T5: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T3: 994872/21887193  T4:  17319/381039   T5:      0/0        T8:     13/861405   
    
    AVERAGE CURRENT
    BCM x1 : 69.9654uA  BCM x3 : 69.9037uA  BCM x10: 47.5233uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.05911        BCM u3 : 0.05908        BCM u10: 0.04112        
    
    BCM d1 : 0.0586         BCM d3 : 0.05853        BCM d10: 0.03884        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4351 at Thu Dec 20 01:57:06 EST 2007
    
    Wien angle : 6.19568
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 2.75827
    Left Arm arm angle : 14.9985
    Right Arm D1 momentum : 2.81475
    Right Arm arm angle : 15.0039
    HALLA:p : 2845.39
    HALLA:dpp : -9.15887e-05
    Tiefenbach Hall A energy : 2845.39
    Left Arm Top VDC Current : -0.927734
    Left Arm Bottom VDC Current : -3.27148
    Left Arm Q1 momentum : 2.75824
    Left Arm Q1 power supply : 2075.11
    Left Arm Q1 gauss meter : -0.1751
    Left Arm Q2 gauss meter : 0.6245
    Left Arm Q2 power supply current : 1187.98
    Left Arm Q2 momentum : 2.7589
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 955.583
    Left Arm D1 momentum : 2.75827
    Left Arm D1 NMR : 1.02114
    Left Arm Q3 gauss meter : -0.5558
    Left Arm Q3 power supply current : 1098.01
    Left Arm Q3 momentum : 2.758
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 2.81453
    Right Arm Q1 power supply : 2116.34
    Right Arm Q1 gauss meter : -0.05281
    Right Arm Q2 power supply current : 1211.33
    Right Arm Q2 momentum : 2.81464
    Right Arm Q2 gauss meter : 0.6337
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 1003.42
    Right Arm D1 momentum : 2.81475
    Right Arm D1 NMR : 1.04452
    Right Arm Q3 power supply current : 1120.14
    Right Arm Q3 momentum : 2.81507
    Right Arm Q3 gauss meter : 0.5011
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 69.9986
    Current on Unser monitor : 80.7559
    Current on Upstream bcm : 70.0352
    Current on Downstream bcm : 69.962
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 109.433
    Hall C Current : 40.17
    MBSY1c magnet current (amp) : 118.639
    MBSY1c Bdl : 711246
    Hall A momentum (Tiefenbach) (HALLA:p) : 2845.41
    Hall A momentum orbit correction (dpp) : -8.75189e-05
    Hall A setup momentum (MMSHLAE) : 2839.38
    Hall A energy (halla_MeV) : 2845.41
    Hall C energy (hallc_MeV) : 3549.63
    Delta(E)/E width (MV_AI_DXWID) : 1.64761
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : -1.98319
    IPM1H04A.YPOS : 0.0505187
    IPM1H04B.XPOS : -1.99769
    IPM1H04B.YPOS : -0.0026406
    Left Arm Collimator : 0.871387
    HacL_HPE1313A:0_Ch58 : -0.189453
    HacL_HPE1313A:0_Ch55 : 22.998
    HacL_HPE1313A:0_Ch54 : 0.00585938
    SLI data valid? : Yes
    SLI horiz size mm : 0.287513
    SLI Energy spread *10^5 : 5.32432
    SLI x position : 1.58012
    SLI vert. size mm : 0.104458
    SLI y position : 1.50986
    -----
    Target : Optics
    fan frequency loop 1 : 59.5
    fan frequency loop 3 : 60
    Encoder position : 1.28675e+07
    Target type : 1.28675e+07
    temperature loop 1(1) : 7
    temperature loop 1(3) : 7.04
    Heat exchange He : 7.4
    temperature loop 3(1) : 18.83
    temperature loop 3(3) : 19
    Heat exchange H2 : 18.5
    HPH He loop 1 : 107.687
    HPH He loop 2 : 8.61639
    HPH H2 loop 3 : 440.701
    -----