    keyword=End_of_Run_4352
    ****************************
     Run Number: 4352
     End of Run Comment:
    Run_type=Optics,target_type=Optics,beam_e0=2.839,beam_raster=off,leftarm_p=2.702,leftarm_theta=15,leftarm_colli=out,rightarm_p=2.702,rightarm_theta=15,rightarm_colli=out,comment_text=
     
    
    PRESCALE FACTORS:ps1=16777212   ps2=16777215   ps3=42   ps4=28   ps5=65535   ps6=65535   ps7=9999   ps8=65535   
    
    EVENTS   : 1003023      
    TIME     : 14.772 mins  
    
    DEAD TIME:   1.03%      
    
    TRIGGER RATES:   PRES/REAL
    T3:1124.4/47224.7 Hz   T4:19.0/532.2 Hz   T5: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T3: 996602/41857285  T4:  16846/471695   T5:      0/0        T8:     13/907616   
    
    AVERAGE CURRENT
    BCM x1 : 66.7142uA  BCM x3 : 66.6552uA  BCM x10: 45.5964uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.05937        BCM u3 : 0.05933        BCM u10: 0.04159        
    
    BCM d1 : 0.0589         BCM d3 : 0.05882        BCM d10: 0.03924        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4352 at Thu Dec 20 02:17:08 EST 2007
    
    Wien angle : 6.19568
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 2.70204
    Left Arm arm angle : 14.9985
    Right Arm D1 momentum : 2.68435
    Right Arm arm angle : 15.0039
    HALLA:p : 2845.43
    HALLA:dpp : -7.88596e-05
    Tiefenbach Hall A energy : 2845.43
    Left Arm Top VDC Current : -1.5625
    Left Arm Bottom VDC Current : -1.02539
    Left Arm Q1 momentum : 2.70209
    Left Arm Q1 power supply : 2032.87
    Left Arm Q1 gauss meter : -0.17155
    Left Arm Q2 gauss meter : 0.6116
    Left Arm Q2 power supply current : 1163.35
    Left Arm Q2 momentum : 2.70171
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 934.29
    Left Arm D1 momentum : 2.70204
    Left Arm D1 NMR : 1.00028
    Left Arm Q3 gauss meter : -0.5446
    Left Arm Q3 power supply current : 1075.63
    Left Arm Q3 momentum : 2.70179
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 2.70202
    Right Arm Q1 power supply : 2031.75
    Right Arm Q1 gauss meter : -0.05073
    Right Arm Q2 power supply current : 1162.88
    Right Arm Q2 momentum : 2.70207
    Right Arm Q2 gauss meter : 0.6085
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 933.416
    Right Arm D1 momentum : 2.6842
    Right Arm D1 NMR : 0.99603
    Right Arm Q3 power supply current : 1075.18
    Right Arm Q3 momentum : 2.70208
    Right Arm Q3 gauss meter : 0.4811
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 70.0596
    Current on Unser monitor : 82.0438
    Current on Upstream bcm : 70.1639
    Current on Downstream bcm : 69.9554
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 109.043
    Hall C Current : 40.08
    MBSY1c magnet current (amp) : 118.639
    MBSY1c Bdl : 711246
    Hall A momentum (Tiefenbach) (HALLA:p) : 2845.41
    Hall A momentum orbit correction (dpp) : -8.4378e-05
    Hall A setup momentum (MMSHLAE) : 2839.38
    Hall A energy (halla_MeV) : 2845.41
    Hall C energy (hallc_MeV) : 3549.66
    Delta(E)/E width (MV_AI_DXWID) : 1.63343
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : -1.99164
    IPM1H04A.YPOS : 0.067135
    IPM1H04B.XPOS : -2.00359
    IPM1H04B.YPOS : 0.0159733
    Left Arm Collimator : 0.871387
    HacL_HPE1313A:0_Ch58 : -0.189453
    HacL_HPE1313A:0_Ch55 : 22.998
    HacL_HPE1313A:0_Ch54 : 0.00537109
    SLI data valid? : Yes
    SLI horiz size mm : 0.299086
    SLI Energy spread *10^5 : 5.53863
    SLI x position : 1.58012
    SLI vert. size mm : 0.104684
    SLI y position : 1.50986
    -----
    Target : Optics
    fan frequency loop 1 : 60
    fan frequency loop 3 : 59.5
    Encoder position : 1.28675e+07
    Target type : 1.28675e+07
    temperature loop 1(1) : 7
    temperature loop 1(3) : 7.05
    Heat exchange He : 7.4
    temperature loop 3(1) : 18.83
    temperature loop 3(3) : 19
    Heat exchange H2 : 18.5
    HPH He loop 1 : 107.14
    HPH He loop 2 : 10.4327
    HPH H2 loop 3 : 452.573
    -----