Privacy and Security Notice
Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 02:48:58 on December 20, 2007
Entry number 222335
keyword=End_of_Run_4353
****************************
Run Number: 4353
End of Run Comment:
Run_type=Optics,target_type=LH2 15cm Loop3,beam_e0=2.839,beam_raster=off,leftarm_p=2.677,leftarm_theta=15,leftarm_colli=out,rightarm_p=2.702,rightarm_theta=15,rightarm_colli=out,comment_text=
PRESCALE FACTORS:ps1=16777212 ps2=16777215 ps3=93 ps4=34 ps5=65535 ps6=65535 ps7=9999 ps8=65535
EVENTS : 755295
TIME : 12.059 mins
DEAD TIME: 1.19%
TRIGGER RATES: PRES/REAL
T3:1037.8/96511.4 Hz T4:18.7/634.6 Hz T5: 0.0/0.0 Hz T8: 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T3: 750875/69831431 T4: 13504/459153 T5: 0/0 T8: 11/740922
AVERAGE CURRENT
BCM x1 : 13.5463uA BCM x3 : 13.5526uA BCM x10: 13.6629uA
APPROXIMATE BCM CHARGES (C)
BCM u1 : 0.009835 BCM u3 : 0.009838 BCM u10: 0.009909
BCM d1 : 0.009768 BCM d3 : 0.009774 BCM d10: 0.009863
****************************
End-of-run EPICS data for Run Number 4353 at Thu Dec 20 02:48:54 EST 2007
Wien angle : 6.19568
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 2.67655
Left Arm arm angle : 14.9985
Right Arm D1 momentum : 2.70175
Right Arm arm angle : 15.0039
HALLA:p : 2845.59
HALLA:dpp : -2.26523e-05
Tiefenbach Hall A energy : 2845.59
Left Arm Top VDC Current : -9.86328
Left Arm Bottom VDC Current : -2.7832
Left Arm Q1 momentum : 2.67653
Left Arm Q1 power supply : 2013.64
Left Arm Q1 gauss meter : -0.16993
Left Arm Q2 gauss meter : 0.6059
Left Arm Q2 power supply current : 1152.48
Left Arm Q2 momentum : 2.67645
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 924.632
Left Arm D1 momentum : 2.67655
Left Arm D1 NMR : 0.990819
Left Arm Q3 gauss meter : -0.5395
Left Arm Q3 power supply current : 1065.56
Left Arm Q3 momentum : 2.67648
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 2.70195
Right Arm Q1 power supply : 2031.69
Right Arm Q1 gauss meter : -0.05072
Right Arm Q2 power supply current : 1162.88
Right Arm Q2 momentum : 2.70207
Right Arm Q2 gauss meter : 0.6085
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 959.013
Right Arm D1 momentum : 2.70175
Right Arm D1 NMR : 1.00259
Right Arm Q3 power supply current : 1075.18
Right Arm Q3 momentum : 2.70209
Right Arm Q3 gauss meter : 0.4811
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 14.9861
Current on Unser monitor : 27.0653
Current on Upstream bcm : 14.9935
Current on Downstream bcm : 14.9788
Upstream Cavity Coefficient : 43.377
Downstream Cavity Coefficient : 42.913
Current on IBC0L02 (source) : 96.7379
Hall C Current : 81.66
MBSY1c magnet current (amp) : 118.639
MBSY1c Bdl : 711246
Hall A momentum (Tiefenbach) (HALLA:p) : 2845.6
Hall A momentum orbit correction (dpp) : -1.8137e-05
Hall A setup momentum (MMSHLAE) : 2839.38
Hall A energy (halla_MeV) : 2845.6
Hall C energy (hallc_MeV) : 3549.63
Delta(E)/E width (MV_AI_DXWID) : 1.59921
IPM1C12.XPOS : 0
IPM1H04A.XPOS : -2.01726
IPM1H04A.YPOS : -0.00243038
IPM1H04B.XPOS : -2.00812
IPM1H04B.YPOS : -0.0138888
Left Arm Collimator : 0.871387
HacL_HPE1313A:0_Ch58 : -0.189453
HacL_HPE1313A:0_Ch55 : 23.0469
HacL_HPE1313A:0_Ch54 : 0.00634766
SLI data valid? : Yes
SLI horiz size mm : 0.218142
SLI Energy spread *10^5 : 4.03967
SLI x position : 1.59503
SLI vert. size mm : 0.0935027
SLI y position : 1.51737
-----
Target : L3 15cm
fan frequency loop 1 : 60
fan frequency loop 3 : 60
Encoder position : 1.63491e+07
Target type : 1.63491e+07
temperature loop 1(1) : 7
temperature loop 1(3) : 7.04
Heat exchange He : 7.4
temperature loop 3(1) : 18.77
temperature loop 3(3) : 19
Heat exchange H2 : 18.5
HPH He loop 1 : 114.926
HPH He loop 2 : 7.23539
HPH H2 loop 3 : 376.736
-----