     Run Number: 4354
     End of Run Comment:
    Run_type=Optics,target_type=LH2 15cm Loop3,beam_e0=2.839,beam_raster=on,leftarm_p=2.677,leftarm_theta=15,leftarm_colli=sieve,rightarm_p=2.625,rightarm_theta=15,rightarm_colli=out,comment_text=
     
    
    PRESCALE FACTORS:ps1=16777212   ps2=16777215   ps3=2   ps4=4   ps5=65535   ps6=65535   ps7=9999   ps8=65535   
    
    EVENTS   : 1309562      
    TIME     : 21.885 mins  
    
    DEAD TIME:   3.88%      
    
    TRIGGER RATES:   PRES/REAL
    T3:1012.9/2025.8 Hz   T4:24.7/98.7 Hz   T5: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T3:1330036/2660073  T4:  32388/129553   T5:      0/0        T8:     20/1344592  
    
    AVERAGE CURRENT
    BCM x1 : 19.5604uA  BCM x3 : 19.5672uA  BCM x10: 19.7206uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.02576        BCM u3 : 0.02577        BCM u10: 0.02595        
    
    BCM d1 : 0.0256         BCM d3 : 0.02561        BCM d10: 0.02584        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4354 at Thu Dec 20 03:42:32 EST 2007
    
    Wien angle : 6.19568
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 2.67655
    Left Arm arm angle : 14.9985
    Right Arm D1 momentum : 2.62777
    Right Arm arm angle : 15.0039
    HALLA:p : 2845.33
    HALLA:dpp : -0.000112875
    Tiefenbach Hall A energy : 2845.33
    Left Arm Top VDC Current : 2.73438
    Left Arm Bottom VDC Current : 3.90625
    Left Arm Q1 momentum : 2.67653
    Left Arm Q1 power supply : 2013.64
    Left Arm Q1 gauss meter : -0.16995
    Left Arm Q2 gauss meter : 0.6059
    Left Arm Q2 power supply current : 1152.48
    Left Arm Q2 momentum : 2.67645
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 924.632
    Left Arm D1 momentum : 2.67655
    Left Arm D1 NMR : 0.990819
    Left Arm Q3 gauss meter : -0.5395
    Left Arm Q3 power supply current : 1065.56
    Left Arm Q3 momentum : 2.67648
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 2.62503
    Right Arm Q1 power supply : 1973.85
    Right Arm Q1 gauss meter : -0.0493
    Right Arm Q2 power supply current : 1129.77
    Right Arm Q2 momentum : 2.62512
    Right Arm Q2 gauss meter : 0.5912
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 935.702
    Right Arm D1 momentum : 2.62777
    Right Arm D1 NMR : 0.975133
    Right Arm Q3 power supply current : 1044.57
    Right Arm Q3 momentum : 2.62514
    Right Arm Q3 gauss meter : 0.4673
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 20.3166
    Current on Unser monitor : 32.3934
    Current on Upstream bcm : 20.3471
    Current on Downstream bcm : 20.2862
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 99.0254
    Hall C Current : 78.84
    MBSY1c magnet current (amp) : 118.639
    MBSY1c Bdl : 711246
    Hall A momentum (Tiefenbach) (HALLA:p) : 2845.33
    Hall A momentum orbit correction (dpp) : -0.000112875
    Hall A setup momentum (MMSHLAE) : 2839.38
    Hall A energy (halla_MeV) : 2845.33
    Hall C energy (hallc_MeV) : 3549.46
    Delta(E)/E width (MV_AI_DXWID) : 1.57917
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : -2.00135
    IPM1H04A.YPOS : 0.0334436
    IPM1H04B.XPOS : -2.00043
    IPM1H04B.YPOS : 0.000972092
    Left Arm Collimator : 0.368506
    HacL_HPE1313A:0_Ch58 : -0.19043
    HacL_HPE1313A:0_Ch55 : 23.0469
    HacL_HPE1313A:0_Ch54 : 0.00634766
    SLI data valid? : Yes
    SLI horiz size mm : 0.236652
    SLI Energy spread *10^5 : 4.38245
    SLI x position : 1.56522
    SLI vert. size mm : 0.0922272
    SLI y position : 1.51737
    -----
    Target : L3 15cm
    fan frequency loop 1 : 59.5
    fan frequency loop 3 : 59.5
    Encoder position : 1.63491e+07
    Target type : 1.63491e+07
    temperature loop 1(1) : 7
    temperature loop 1(3) : 7.05
    Heat exchange He : 7.4
    temperature loop 3(1) : 18.76
    temperature loop 3(3) : 19
    Heat exchange H2 : 18.5
    HPH He loop 1 : 110.999
    HPH He loop 2 : 7.77332
    HPH H2 loop 3 : 365.912
    -----