Privacy and Security Notice
Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 04:02:24 on December 20, 2007
Entry number 222346
keyword=End_of_Run_4355
****************************
Run Number: 4355
End of Run Comment:
Run_type=Optics,target_type=LH2 15cm Loop3,beam_e0=2.839,beam_raster=on,leftarm_p=2.625,leftarm_theta=15,leftarm_colli=sieve,rightarm_p=2.625,rightarm_theta=15,rightarm_colli=sieve,comment_text=
PRESCALE FACTORS:ps1=16777212 ps2=16777215 ps3=2 ps4=5 ps5=65535 ps6=65535 ps7=9999 ps8=65535
EVENTS : 1122326
TIME : 13.580 mins
DEAD TIME: 6.10%
TRIGGER RATES: PRES/REAL
T3:1445.3/2890.5 Hz T4:21.6/108.2 Hz T5: 0.0/0.0 Hz T8: 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T3:1177620/2355241 T4: 17639/88199 T5: 0/0 T8: 12/834376
AVERAGE CURRENT
BCM x1 : 20.1470uA BCM x3 : 20.1538uA BCM x10: 20.3114uA
APPROXIMATE BCM CHARGES (C)
BCM u1 : 0.01647 BCM u3 : 0.01647 BCM u10: 0.01659
BCM d1 : 0.01637 BCM d3 : 0.01637 BCM d10: 0.01651
****************************
End-of-run EPICS data for Run Number 4355 at Thu Dec 20 04:02:21 EST 2007
Wien angle : 6.19568
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 2.62506
Left Arm arm angle : 14.9985
Right Arm D1 momentum : 2.62496
Right Arm arm angle : 15.0039
HALLA:p : 2845.44
HALLA:dpp : -7.40062e-05
Tiefenbach Hall A energy : 2845.44
Left Arm Top VDC Current : -0.195312
Left Arm Bottom VDC Current : 0.78125
Left Arm Q1 momentum : 2.62514
Left Arm Q1 power supply : 1974.92
Left Arm Q1 gauss meter : -0.16667
Left Arm Q2 gauss meter : 0.5943
Left Arm Q2 power supply current : 1130.26
Left Arm Q2 momentum : 2.62485
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 905.294
Left Arm D1 momentum : 2.62506
Left Arm D1 NMR : 0.971715
Left Arm Q3 gauss meter : -0.5292
Left Arm Q3 power supply current : 1045.13
Left Arm Q3 momentum : 2.62518
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 2.62503
Right Arm Q1 power supply : 1973.85
Right Arm Q1 gauss meter : -0.0493
Right Arm Q2 power supply current : 1129.77
Right Arm Q2 momentum : 2.62512
Right Arm Q2 gauss meter : 0.5912
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 929.054
Right Arm D1 momentum : 2.62496
Right Arm D1 NMR : 0.97409
Right Arm Q3 power supply current : 1044.56
Right Arm Q3 momentum : 2.62514
Right Arm Q3 gauss meter : 0.4674
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 20.0485
Current on Unser monitor : 31.9063
Current on Upstream bcm : 20.0578
Current on Downstream bcm : 20.0392
Upstream Cavity Coefficient : 43.377
Downstream Cavity Coefficient : 42.913
Current on IBC0L02 (source) : 98.2532
Hall C Current : 79.17
MBSY1c magnet current (amp) : 118.639
MBSY1c Bdl : 711246
Hall A momentum (Tiefenbach) (HALLA:p) : 2845.44
Hall A momentum orbit correction (dpp) : -7.54807e-05
Hall A setup momentum (MMSHLAE) : 2839.38
Hall A energy (halla_MeV) : 2845.44
Hall C energy (hallc_MeV) : 3549.63
Delta(E)/E width (MV_AI_DXWID) : 1.59032
IPM1C12.XPOS : 0
IPM1H04A.XPOS : -2.00078
IPM1H04A.YPOS : 0.0420231
IPM1H04B.XPOS : -1.99643
IPM1H04B.YPOS : 0.00283331
Left Arm Collimator : 0.368555
HacL_HPE1313A:0_Ch58 : -0.189941
HacL_HPE1313A:0_Ch55 : 22.998
HacL_HPE1313A:0_Ch54 : 0.00585938
SLI data valid? : Yes
SLI horiz size mm : 0.231567
SLI Energy spread *10^5 : 4.28827
SLI x position : 1.58012
SLI vert. size mm : 0.0906071
SLI y position : 1.51737
-----
Target : L3 15cm
fan frequency loop 1 : 59.5
fan frequency loop 3 : 60
Encoder position : 1.63491e+07
Target type : 1.63491e+07
temperature loop 1(1) : 7
temperature loop 1(3) : 7.05
Heat exchange He : 7.4
temperature loop 3(1) : 18.77
temperature loop 3(3) : 19
Heat exchange H2 : 18.5
HPH He loop 1 : 106.05
HPH He loop 2 : 6.84459
HPH H2 loop 3 : 367.868
-----