Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 04:02:26 on December 20, 2007

    Entry number 222347

    keyword=End_of_Run_22204
    ****************************
     Run Number: 22204
     End of Run Comment:
    Run_type=Optics,target_type=LH2 15cm Loop3,beam_e0=2.839,beam_raster=off,beam_halfwaveplate=out,leftarm_p=2.625,leftarm_theta=15,leftarm_colli=sieve,rightarm_p=2.625,rightarm_theta=15,rightarm_colli=sieve,comment_text=
     
    
    PRESCALE FACTORS:ps1=2   ps2=5   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 1061111      
    TIME     : 13.525 mins  
    
    DEAD TIME:   5.41%      
    
    TRIGGER RATES:   PRES/REAL
    T1:1363.2/2726.5 Hz   T2:19.3/96.3 Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:1106231/2212463  T2:  15629/78145    T8:     12/830953   
    
    AVERAGE CURRENT
    BCM x1 : 20.1768uA  BCM x3 : 20.1825uA  BCM x10: 10.1633uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.01643        BCM u3 : 0.01643        BCM u10: 9.01E-05       
    
    BCM d1 : 0.01631        BCM d3 : 0.01633        BCM d10: 0.0164         
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 22204 at Thu Dec 20 04:02:22 EST 2007
    
    Wien angle : 6.19568
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 2.62506
    Left Arm arm angle : 14.9985
    Right Arm D1 momentum : 2.62496
    Right Arm arm angle : 15.0039
    HALLA:p : 2845.44
    HALLA:dpp : -7.40062e-05
    Tiefenbach Hall A energy : 2845.44
    Left Arm Top VDC Current : -0.195312
    Left Arm Bottom VDC Current : 0.78125
    Left Arm Q1 momentum : 2.62507
    Left Arm Q1 power supply : 1974.98
    Left Arm Q1 gauss meter : -0.16667
    Left Arm Q2 gauss meter : 0.5943
    Left Arm Q2 power supply current : 1130.26
    Left Arm Q2 momentum : 2.62485
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 905.294
    Left Arm D1 momentum : 2.62506
    Left Arm D1 NMR : 0.971715
    Left Arm Q3 gauss meter : -0.5292
    Left Arm Q3 power supply current : 1045.13
    Left Arm Q3 momentum : 2.62518
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 2.62503
    Right Arm Q1 power supply : 1973.85
    Right Arm Q1 gauss meter : -0.0493
    Right Arm Q2 power supply current : 1129.77
    Right Arm Q2 momentum : 2.62512
    Right Arm Q2 gauss meter : 0.5912
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 929.054
    Right Arm D1 momentum : 2.62496
    Right Arm D1 NMR : 0.974091
    Right Arm Q3 power supply current : 1044.56
    Right Arm Q3 momentum : 2.62514
    Right Arm Q3 gauss meter : 0.4674
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 20.0485
    Current on Unser monitor : 31.9063
    Current on Upstream bcm : 20.0578
    Current on Downstream bcm : 20.0392
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 98.2532
    Hall C Current : 79.38
    MBSY1c magnet current (amp) : 118.639
    MBSY1c Bdl : 711246
    Hall A momentum (Tiefenbach) (HALLA:p) : 2845.44
    Hall A momentum orbit correction (dpp) : -7.54807e-05
    Hall A setup momentum (MMSHLAE) : 2839.38
    Hall A energy (halla_MeV) : 2845.44
    Hall C energy (hallc_MeV) : 3549.63
    Delta(E)/E width (MV_AI_DXWID) : 1.58066
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : -2.00476
    IPM1H04A.YPOS : 0.0384227
    IPM1H04B.XPOS : -1.99648
    IPM1H04B.YPOS : 0.00283331
    Left Arm Collimator : 0.368506
    HacL_HPE1313A:0_Ch58 : -0.189941
    HacL_HPE1313A:0_Ch55 : 22.998
    HacL_HPE1313A:0_Ch54 : 0.00585938
    -----
    SLI data valid? : Yes
    SLI horiz size mm : 0.231567
    SLI Energy spread *10^5 : 4.28827
    SLI x position : 1.58012
    SLI vert. size mm : 0.0906071
    SLI y position : 1.51737
    -----
    Target : L3 15cm
    Vacuum Pressure : 4.07504e-07
    fan frequency loop 1 : 60
    fan frequency loop 3 : 60
    Encoder position : 1.63491e+07
    Target type : 1.63491e+07
    temperature loop 1(1) : 7
    temperature loop 1(3) : 7.05
    Heat exchange He : 7.4
    temperature loop 3(1) : 18.77
    temperature loop 3(3) : 19
    Heat exchange H2 : 18.5
    HPH He loop 1 : 106.05
    HPH H2 loop 3 : 367.868