    keyword=End_of_Run_22206
    ****************************
     Run Number: 22206
     End of Run Comment:
    Run_type=Optics,target_type=LH2 15cm Loop3,beam_e0=2.839,beam_raster=on,beam_halfwaveplate=out,leftarm_p=2.574,leftarm_theta=15,leftarm_colli=out,rightarm_p=2.574,rightarm_theta=15,rightarm_colli=out,comment_text=
     
    
    PRESCALE FACTORS:ps1=80   ps2=43   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 807963       
    TIME     : 11.843 mins  
    
    DEAD TIME:   1.35%      
    
    TRIGGER RATES:   PRES/REAL
    T1:1133.3/90666.3 Hz   T2:19.3/828.0 Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1: 805340/64427246  T2:  13683/588410   T8:     11/727652   
    
    AVERAGE CURRENT
    BCM x1 : 9.5792 uA  BCM x3 : 9.5842 uA  BCM x10: 6.8925 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.006836       BCM u3 : 0.006836       BCM u10: 0.002973       
    
    BCM d1 : 0.006778       BCM d3 : 0.006785       BCM d10: 0.006822       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 22206 at Thu Dec 20 05:01:57 EST 2007
    
    Wien angle : 6.19568
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 2.57357
    Left Arm arm angle : 14.9985
    Right Arm D1 momentum : 2.57335
    Right Arm arm angle : 15.0039
    HALLA:p : 2845.48
    HALLA:dpp : -6.18643e-05
    Tiefenbach Hall A energy : 2845.48
    Left Arm Top VDC Current : -7.66602
    Left Arm Bottom VDC Current : -6.93359
    Left Arm Q1 momentum : 2.57367
    Left Arm Q1 power supply : 1936.26
    Left Arm Q1 gauss meter : -0.16341
    Left Arm Q2 gauss meter : 0.5827
    Left Arm Q2 power supply current : 1108.12
    Left Arm Q2 momentum : 2.57343
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 886.02
    Left Arm D1 momentum : 2.57357
    Left Arm D1 NMR : 0.952606
    Left Arm Q3 gauss meter : -0.5187
    Left Arm Q3 power supply current : 1024.36
    Left Arm Q3 momentum : 2.573
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 2.57361
    Right Arm Q1 power supply : 1935.19
    Right Arm Q1 gauss meter : -0.04833
    Right Arm Q2 power supply current : 1107.49
    Right Arm Q2 momentum : 2.57337
    Right Arm Q2 gauss meter : 0.5796
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 908.533
    Right Arm D1 momentum : 2.57335
    Right Arm D1 NMR : 0.95495
    Right Arm Q3 power supply current : 1023.98
    Right Arm Q3 momentum : 2.57341
    Right Arm Q3 gauss meter : 0.4581
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 10.0168
    Current on Unser monitor : 22.6563
    Current on Upstream bcm : 10.0277
    Current on Downstream bcm : 10.0059
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 83.6078
    Hall C Current : 74.88
    MBSY1c magnet current (amp) : 118.639
    MBSY1c Bdl : 711246
    Hall A momentum (Tiefenbach) (HALLA:p) : 2845.5
    Hall A momentum orbit correction (dpp) : -5.39218e-05
    Hall A setup momentum (MMSHLAE) : 2839.38
    Hall A energy (halla_MeV) : 2845.5
    Hall C energy (hallc_MeV) : 3549.63
    Delta(E)/E width (MV_AI_DXWID) : 1.568
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : -2.00082
    IPM1H04A.YPOS : 0.0366129
    IPM1H04B.XPOS : -2.00051
    IPM1H04B.YPOS : 0.00390226
    Left Arm Collimator : 0.871289
    HacL_HPE1313A:0_Ch58 : -0.19043
    HacL_HPE1313A:0_Ch55 : 23.0469
    HacL_HPE1313A:0_Ch54 : 0.00634766
    -----
    SLI data valid? : Yes
    SLI horiz size mm : 0.226737
    SLI Energy spread *10^5 : 4.19884
    SLI x position : 1.58012
    SLI vert. size mm : 0.282713
    SLI y position : 1.51737
    -----
    Target : L3 15cm
    Vacuum Pressure : 3.86584e-07
    fan frequency loop 1 : 59.5
    fan frequency loop 3 : 60
    Encoder position : 1.63491e+07
    Target type : 1.63491e+07
    temperature loop 1(1) : 7
    temperature loop 1(3) : 7.04
    Heat exchange He : 7.4
    temperature loop 3(1) : 18.8
    temperature loop 3(3) : 19
    Heat exchange H2 : 18.5
    HPH He loop 1 : 106.594
    HPH H2 loop 3 : 416.387