Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 05:53:32 on December 20, 2007

    Entry number 222368

    keyword=End_of_Run_4360
    ****************************
     Run Number: 4360
     End of Run Comment:
    Run_type=Optics,target_type=LH2 15cm Loop3,beam_e0=2.839,beam_raster=on,leftarm_p=2.522,leftarm_theta=15,leftarm_colli=sieve,rightarm_p=2.522,rightarm_theta=15,rightarm_colli=sieve,comment_text=
     
    
    PRESCALE FACTORS:ps1=16777212   ps2=16777215   ps3=2   ps4=2   ps5=65535   ps6=65535   ps7=9999   ps8=65535   
    
    EVENTS   : 1301920      
    TIME     : 22.637 mins  
    
    DEAD TIME:   4.01%      
    
    TRIGGER RATES:   PRES/REAL
    T3:973.6/1947.2 Hz   T4:25.0/50.1 Hz   T5: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T3:1322321/2644643  T4:  34023/68046    T5:      0/0        T8:     21/1390802  
    
    AVERAGE CURRENT
    BCM x1 : 9.2548 uA  BCM x3 : 9.2602 uA  BCM x10: 9.3358 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.01257        BCM u3 : 0.01258        BCM u10: 0.01267        
    
    BCM d1 : 0.01257        BCM d3 : 0.01257        BCM d10: 0.01269        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4360 at Thu Dec 20 05:53:27 EST 2007
    
    Wien angle : 6.19568
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 2.5221
    Left Arm arm angle : 14.9985
    Right Arm D1 momentum : 2.52403
    Right Arm arm angle : 15.0039
    HALLA:p : 2845.52
    HALLA:dpp : -4.63898e-05
    Tiefenbach Hall A energy : 2845.52
    Left Arm Top VDC Current : 3.02734
    Left Arm Bottom VDC Current : 4.15039
    Left Arm Q1 momentum : 2.52221
    Left Arm Q1 power supply : 1897.54
    Left Arm Q1 gauss meter : -0.16015
    Left Arm Q2 gauss meter : 0.571
    Left Arm Q2 power supply current : 1085.92
    Left Arm Q2 momentum : 2.52188
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 866.824
    Left Arm D1 momentum : 2.5221
    Left Arm D1 NMR : 0.933509
    Left Arm Q3 gauss meter : -0.5085
    Left Arm Q3 power supply current : 1004.05
    Left Arm Q3 momentum : 2.52197
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 2.52212
    Right Arm Q1 power supply : 1896.47
    Right Arm Q1 gauss meter : -0.04738
    Right Arm Q2 power supply current : 1085.32
    Right Arm Q2 momentum : 2.52186
    Right Arm Q2 gauss meter : 0.568
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 893.281
    Right Arm D1 momentum : 2.52403
    Right Arm D1 NMR : 0.936642
    Right Arm Q3 power supply current : 1003.51
    Right Arm Q3 momentum : 2.52196
    Right Arm Q3 gauss meter : 0.4491
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 10.089
    Current on Unser monitor : 21.9676
    Current on Upstream bcm : 10.1227
    Current on Downstream bcm : 10.0554
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 93.0565
    Hall C Current : 83.76
    MBSY1c magnet current (amp) : 118.639
    MBSY1c Bdl : 711246
    Hall A momentum (Tiefenbach) (HALLA:p) : 2845.52
    Hall A momentum orbit correction (dpp) : -4.59012e-05
    Hall A setup momentum (MMSHLAE) : 2839.38
    Hall A energy (halla_MeV) : 2845.55
    Hall C energy (hallc_MeV) : 3549.68
    Delta(E)/E width (MV_AI_DXWID) : 1.5204
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : -1.96558
    IPM1H04A.YPOS : 0.0319625
    IPM1H04B.XPOS : -1.99629
    IPM1H04B.YPOS : -0.00636542
    Left Arm Collimator : 0.368408
    HacL_HPE1313A:0_Ch58 : -0.189941
    HacL_HPE1313A:0_Ch55 : 23.1445
    HacL_HPE1313A:0_Ch54 : 0.00732422
    SLI data valid? : Yes
    SLI horiz size mm : 0.228921
    SLI Energy spread *10^5 : 4.23928
    SLI x position : 1.59503
    SLI vert. size mm : 0.0835297
    SLI y position : 1.51737
    -----
    Target : L3 15cm
    fan frequency loop 1 : 60
    fan frequency loop 3 : 59.5
    Encoder position : 1.63491e+07
    Target type : 1.63491e+07
    temperature loop 1(1) : 7
    temperature loop 1(3) : 7.04
    Heat exchange He : 7.4
    temperature loop 3(1) : 18.81
    temperature loop 3(3) : 19
    Heat exchange H2 : 18.5
    HPH He loop 1 : 110.443
    HPH He loop 2 : 7.36806
    HPH H2 loop 3 : 421.614
    -----