Privacy and Security Notice
Main INDEX
Monthly INDEX
PREV
NEXT
User name adev
Log entry time 06:00:39 on December 20, 2007
Entry number 222370
keyword=Start_Run_22208,Run_type=Optics,target_type=LH2 15cm Loop3,beam_e0=2.839,beam_raster=on,beam_halfwaveplate=out,leftarm_p=2.522,leftarm_theta=15,leftarm_colli=out,rightarm_p=2.522,rightarm_theta=15,rightarm_colli=sieve,comment_text=
Run Timestamp: Thu Dec 20 06:00:09 EST 2007
Beginning-of-run EPICS data for Run Number 22208 at Thu Dec 20 06:00:30 EST 2007
Run_type=Optics
target_type=LH2 15cm Loop3
beam_e0=2.839
beam_raster=on
beam_halfwaveplate=out
leftarm_p=2.522
leftarm_theta=15
leftarm_colli=out
rightarm_p=2.522
rightarm_theta=15
rightarm_colli=sieve
comment_text=
; RIGHT SPECTROMETER on adaql1/adev account.
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string.
; Default factor is (2^24)-1 = 16.7M for ps1-4 and (2^16)-1 = 65K for ps5-8.
; T1 = main trigger S1.and.S2
; T2 = efficiency trigger (recommend to keep ~5 Hz)
; T8 = 1024 Hz pulser
; All other prescales should be maxed out.
ps1=2,ps2=3,ps3=16777215,ps4=16777215,ps5=65535,ps6=65535,ps7=65535,ps8=65535
Left Arm Q1 momentum : 2.52221
Left Arm Q1 power supply : 1897.48
Left Arm Q1 gauss meter : -0.16015
Left Arm Q2 power supply current : 1085.92
Left Arm Q2 momentum : 2.52187
Left Arm Q2 gauss meter : 0.571
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 866.852
Left Arm D1 momentum : 2.52217
Left Arm D1 NMR : 0.933536
Left Arm Q3 power supply current : 1004.04
Left Arm Q3 momentum : 2.52197
Left Arm Q3 gauss meter : -0.5085
Left Arm Q3 power supply polarity : disabled
Left Arm B Field Hall Probe (D-G) : -0.901
Right Arm Q1 momentum : 2.52212
Right Arm Q1 power supply : 1896.47
Right Arm Q1 gauss meter : -0.04737
Right Arm Q2 power supply current : 1085.32
Right Arm Q2 momentum : 2.52185
Right Arm Q2 gauss meter : 0.5679
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 888.782
Right Arm D1 momentum : 2.52273
Right Arm D1 NMR : 0.936155
Right Arm Q3 power supply current : 1003.51
Right Arm Q3 momentum : 2.52195
Right Arm Q3 gauss meter : 0.449
Right Arm Q3 power supply polarity : disabled
Right Arm B Field Hall Probe (D-G) : -0.9257
Left Arm Top VDC Current : -2.63672
Left Arm Bottom VDC Current : -2.73438
Left Arm Top VDC voltage : 3.99756
Left Arm Bottom VDC voltage : 4.00244
Right Arm Top VDC voltage : 4.00049
Right Arm Bottom VDC voltage : 3.9917
-----
Average current of the two cavities : 9.96165
Current on Unser monitor : 22.4885
Current on Upstream bcm : 9.98133
Current on Downstream bcm : 9.94197
Upstream Cavity Coefficient : 43.377
Downstream Cavity Coefficient : 42.913
Current on IBC0L02 (source) : 92.0549
Hall C Current : 83.37
Hall A momentum (Tiefenbach) (HALLA:p) : 2845.48
Hall A momentum orbit correction (dpp) : -6.11368e-05
Hall A setup momentum (MMSHLAE) : 2839.38
Hall A energy (halla_MeV) : 2845.48
Hall C energy (hallc_MeV) : 3549.63
Delta(E)/E width (MV_AI_DXWID) : 1.5351
MBSY1c magnet current (amp) : 118.639
MBSY1c Bdl : 711246
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.871338
HacL_HPE1313A:0_Ch58 : -0.189453
HacL_HPE1313A:0_Ch55 : 23.1445
HacL_HPE1313A:0_Ch54 : 0.00732422
Left Arm Angle Floor Angle : 15
Left Arm Angle Vernier : 30.8
Left Arm Scattering Angle : 14.9985
Right Arm Arm Collimator : 0.360449
HacR_HPE1313A:0_Ch58 : -0.618164
HacR_HPE1313A:0_Ch55 : 21.6797
HacR_HPE1313A:0_Ch54 : -0.96582
Right Arm Angle Floor Angle : 15
Right Arm Angle Vernier : -33.5
Right Arm Scattering Angle : 15.0039
-----
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : -1.96407
IPM1H04A.YPOS : 0.0384731
IPM1H04B.XPOS : -1.99706
IPM1H04B.YPOS : 0.0012877
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
-----
Wien angle : 6.19568
Helicity Mode ON/OFF Random/Toggle : OFF
Wien field : 4.0104
Laser attenuation Hall A : 160
Laser power Hall A : 100
Half-wave plate (off=out) : IN
rotating waveplate : 0
Beam Half-wave plate (off=out) : IN
Target : L3 15cm
Vacuum Pressure : 3.92193e-07
fan frequency loop 1 : 60
fan frequency loop 2 : 24
fan frequency loop 3 : 60
Encoder position : 1.63491e+07
Target type : 1.63491e+07
temperature loop 1(1) : 7
temperature loop 1(2) : 7
temperature loop 1(3) : 7.04
Heat exchange He : 7.4
temperature loop 3(1) : 18.81
temperature loop 3(2) : 18.18
temperature loop 3(3) : 19
Heat exchange H2 : 18.5
pressure loop He : 170.934
pressure loop H2 before : 20.3937
pressure loop H2 return : 20.6699
HPH He loop 1 : 106.594
HPH He loop 2 : 6.71674
HPH H2 loop 3 : 424.766
SLI data valid? : Yes
SLI horiz size mm : 0.230554
SLI Energy spread *10^5 : 4.26952
SLI x position : 1.59503
SLI vert. size mm : 0.0993838
SLI y position : 1.51737
Right S2 HV
S2 Slot1 ch0 : -2275
S2 Slot1 ch1 : -2120
S2 Slot1 ch2 : -2276.1
S2 Slot1 ch3 : -2051.3
S2 Slot1 ch4 : -2175.8
S2 Slot1 ch5 : -1990.2
S2 Slot1 ch6 : -2401.6
S2 Slot1 ch7 : -2451.9
S2 Slot1 ch8 : -2251.5
S2 Slot1 ch9 : -2451.9
S2 Slot1 ch10 : -2266.5
S2 Slot1 ch11 : -1995.5
-----
Right S1 HV
S1 Slot2 ch0 : -1720.9
S1 Slot2 ch1 : -1901.6
S1 Slot2 ch2 : -1750.7
S1 Slot2 ch3 : -1746.2
S1 Slot2 ch4 : -1697.7
S1 Slot2 ch5 : -2051.7
S1 Slot2 ch6 : -1812.1
S1 Slot2 ch7 : -1977.4
S1 Slot2 ch8 : -1827
S1 Slot2 ch9 : -1866.7
S1 Slot2 ch10 : -1876.6
S1 Slot2 ch11 : -1947.2
-----
Right Preshower HV
PS Slot4 ch0 : -976.2
PS Slot4 ch1 : -975.6
PS Slot4 ch2 : -975.9
PS Slot4 ch3 : -1001.5
PS Slot4 ch4 : -989
PS Slot4 ch5 : -988.7
PS Slot4 ch6 : -975.4
PS Slot4 ch7 : -960.9
PS Slot4 ch8 : -975.7
PS Slot4 ch9 : -976.3
PS Slot4 ch10 : -977
PS Slot4 ch11 : -975.9
PS Slot5 ch0 : -975.5
PS Slot5 ch1 : -937
PS Slot5 ch2 : -936.7
PS Slot5 ch3 : -975.5
PS Slot5 ch4 : -975.9
PS Slot5 ch5 : -976.1
PS Slot5 ch6 : -976.5
PS Slot5 ch7 : -976.2
PS Slot5 ch8 : -1061
PS Slot5 ch9 : -1002.5
PS Slot5 ch10 : -976.2
PS Slot5 ch11 : -975.8
PS Slot7 ch0 : -1098.1
PS Slot7 ch1 : -1008.8
PS Slot7 ch2 : -1001.9
PS Slot7 ch3 : -987.9
PS Slot7 ch4 : -989.5
PS Slot7 ch5 : -989.1
PS Slot7 ch6 : -989.5
PS Slot7 ch7 : -975.4
PS Slot7 ch8 : -975.8
PS Slot7 ch9 : -976.5
PS Slot7 ch10 : -989.4
PS Slot7 ch11 : -989.9
PS Slot8 ch0 : -811.2
PS Slot8 ch1 : -976.4
PS Slot8 ch2 : -975.2
PS Slot8 ch3 : -976
PS Slot8 ch4 : -1126.6
PS Slot8 ch5 : -1002.5
PS Slot8 ch6 : -989.9
PS Slot8 ch7 : -1096.4
PS Slot8 ch8 : -976.5
PS Slot8 ch9 : -1098.4
PS Slot8 ch10 : -975
PS Slot8 ch11 : -974.7
-----
Right Cerenkov HV
GCER Slot14 ch0 : -2466.6
GCER Slot14 ch1 : -2571.6
GCER Slot14 ch2 : -2585.4
GCER Slot14 ch3 : -2460.5
GCER Slot14 ch4 : -2525.8
GCER Slot14 ch5 : -2399.4
GCER Slot14 ch6 : -2545.5
GCER Slot14 ch7 : -2555.4
GCER Slot14 ch8 : -2501.5
GCER Slot14 ch9 : -2400.6
GCER Slot14 ch10 : -2201.2
GCER Slot14 ch11 : -2201.2
-----
Right Shower HV
SH Slot1 ch0 : -699.3
SH Slot1 ch1 : -698.9
SH Slot1 ch2 : -699.4
SH Slot1 ch3 : -700.4
SH Slot1 ch4 : -700.7
SH Slot1 ch5 : -700.3
SH Slot1 ch6 : -699.5
SH Slot1 ch7 : -700.5
SH Slot1 ch8 : -700.5
SH Slot1 ch9 : -700.6
SH Slot1 ch10 : -699.7
SH Slot1 ch11 : -700.4
SH Slot2 ch0 : -700.7
SH Slot2 ch1 : -700.2
SH Slot2 ch2 : -699.9
SH Slot2 ch3 : -7.8
SH Slot2 ch4 : -700.9
SH Slot2 ch5 : -701.3
SH Slot2 ch6 : -691.1
SH Slot2 ch7 : -634.4
SH Slot2 ch8 : -666.6
SH Slot2 ch9 : -635.1
SH Slot2 ch10 : -634.8
SH Slot2 ch11 : -666.1
SH Slot4 ch0 : -662
SH Slot4 ch1 : -658.8
SH Slot4 ch2 : -664
SH Slot4 ch3 : -705.2
SH Slot4 ch4 : -691
SH Slot4 ch5 : -665.5
SH Slot4 ch6 : -825.6
SH Slot4 ch7 : -7.9
SH Slot4 ch8 : -699.4
SH Slot4 ch9 : -683.5
SH Slot4 ch10 : -687.6
SH Slot4 ch11 : -634
SH Slot5 ch0 : -645.3
SH Slot5 ch1 : -655.6
SH Slot5 ch2 : -595.4
SH Slot5 ch3 : -608.6
SH Slot5 ch4 : -673.5
SH Slot5 ch5 : -602.8
SH Slot5 ch6 : -655.8
SH Slot5 ch7 : -651.7
SH Slot5 ch8 : -690.8
SH Slot5 ch9 : -679.4
SH Slot5 ch10 : -750.3
SH Slot5 ch11 : -10.1
SH Slot7 ch0 : -759.8
SH Slot7 ch1 : -698.7
SH Slot7 ch2 : -679
SH Slot7 ch3 : -685.3
SH Slot7 ch4 : -671.8
SH Slot7 ch5 : -668.8
SH Slot7 ch6 : -657.4
SH Slot7 ch7 : -650.8
SH Slot7 ch8 : -676.9
SH Slot7 ch9 : -694
SH Slot7 ch10 : -688.2
SH Slot7 ch11 : -704
SH Slot8 ch0 : -675.9
SH Slot8 ch1 : -722.1
SH Slot8 ch2 : -729.7
SH Slot8 ch3 : -7.6
SH Slot8 ch4 : -730.1
SH Slot8 ch5 : -704.3
SH Slot8 ch6 : -697.3
SH Slot8 ch7 : -716.4
SH Slot8 ch8 : -667.9
SH Slot8 ch9 : -676.4
SH Slot8 ch10 : -693.9
SH Slot8 ch11 : -672.7
SH Slot10 ch0 : -675.6
SH Slot10 ch1 : -702.2
SH Slot10 ch2 : -697.4
SH Slot10 ch3 : -715.3
SH Slot10 ch4 : -750
SH Slot10 ch5 : -851.2
SH Slot10 ch6 : -750
SH Slot10 ch7 : -11.1
SH Slot10 ch8 : -21.1
SH Slot10 ch9 : -21.3
SH Slot10 ch10 : -22.6
SH Slot10 ch11 : -19.6
-----