     Run Number: 4362
     End of Run Comment:
    Run_type=Optics,target_type=LH2 15cm Loop3,beam_e0=2.839,beam_raster=on,leftarm_p=2.471,leftarm_theta=15,leftarm_colli=out,rightarm_p=2.522,rightarm_theta=15,rightarm_colli=sieve,comment_text=
     
    
    PRESCALE FACTORS:ps1=16777212   ps2=16777215   ps3=66   ps4=33   ps5=65535   ps6=65535   ps7=9999   ps8=65535   
    
    EVENTS   : 752403       
    TIME     : 13.470 mins  
    
    DEAD TIME:   1.19%      
    
    TRIGGER RATES:   PRES/REAL
    T3:926.4/61141.2 Hz   T4:15.8/519.9 Hz   T5: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T3: 748714/49415161  T4:  12733/420192   T5:      0/0        T8:     12/827611   
    
    AVERAGE CURRENT
    BCM x1 : 7.7346 uA  BCM x3 : 7.7392 uA  BCM x10: 7.8021 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.00625        BCM u3 : 0.006253       BCM u10: 0.006299       
    
    BCM d1 : 0.006252       BCM d3 : 0.006257       BCM d10: 0.006313       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4362 at Thu Dec 20 06:30:04 EST 2007
    
    Wien angle : 6.19568
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 2.47063
    Left Arm arm angle : 14.9985
    Right Arm D1 momentum : 2.52225
    Right Arm arm angle : 15.0039
    HALLA:p : 2845.43
    HALLA:dpp : -8.08805e-05
    Tiefenbach Hall A energy : 2845.42
    Left Arm Top VDC Current : -2.24609
    Left Arm Bottom VDC Current : -8.1543
    Left Arm Q1 momentum : 2.47067
    Left Arm Q1 power supply : 1858.82
    Left Arm Q1 gauss meter : -0.15689
    Left Arm Q2 gauss meter : 0.5595
    Left Arm Q2 power supply current : 1063.82
    Left Arm Q2 momentum : 2.47056
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 847.694
    Left Arm D1 momentum : 2.47063
    Left Arm D1 NMR : 0.914411
    Left Arm Q3 gauss meter : -0.498
    Left Arm Q3 power supply current : 983.493
    Left Arm Q3 momentum : 2.47035
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 2.52212
    Right Arm Q1 power supply : 1896.52
    Right Arm Q1 gauss meter : -0.04737
    Right Arm Q2 power supply current : 1085.32
    Right Arm Q2 momentum : 2.52185
    Right Arm Q2 gauss meter : 0.5679
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 889.264
    Right Arm D1 momentum : 2.52226
    Right Arm D1 NMR : 0.935979
    Right Arm Q3 power supply current : 1003.51
    Right Arm Q3 momentum : 2.52196
    Right Arm Q3 gauss meter : 0.449
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 10.1222
    Current on Unser monitor : 21.8468
    Current on Upstream bcm : 10.079
    Current on Downstream bcm : 10.1654
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 92.693
    Hall C Current : 84.51
    MBSY1c magnet current (amp) : 118.639
    MBSY1c Bdl : 711246
    Hall A momentum (Tiefenbach) (HALLA:p) : 2845.42
    Hall A momentum orbit correction (dpp) : -7.72726e-05
    Hall A setup momentum (MMSHLAE) : 2839.38
    Hall A energy (halla_MeV) : 2845.43
    Hall C energy (hallc_MeV) : 3548.85
    Delta(E)/E width (MV_AI_DXWID) : 1.48672
    IPM1C12.XPOS : -0.265641
    IPM1H04A.XPOS : -1.96341
    IPM1H04A.YPOS : 0.0139657
    IPM1H04B.XPOS : -2.00339
    IPM1H04B.YPOS : -0.0143456
    Left Arm Collimator : 0.871387
    HacL_HPE1313A:0_Ch58 : -0.189453
    HacL_HPE1313A:0_Ch55 : 23.0957
    HacL_HPE1313A:0_Ch54 : 0.00634766
    SLI data valid? : Yes
    SLI horiz size mm : 0.21881
    SLI Energy spread *10^5 : 4.05204
    SLI x position : 1.59503
    SLI vert. size mm : 0.105986
    SLI y position : 1.51737
    -----
    Target : L3 15cm
    fan frequency loop 1 : 60
    fan frequency loop 3 : 59.5
    Encoder position : 1.63491e+07
    Target type : 1.63491e+07
    temperature loop 1(1) : 7
    temperature loop 1(3) : 7.04
    Heat exchange He : 7.4
    temperature loop 3(1) : 18.81
    temperature loop 3(3) : 19
    Heat exchange H2 : 18.5
    HPH He loop 1 : 112.673
    HPH He loop 2 : 7.50194
    HPH H2 loop 3 : 434.292
    -----