    keyword=End_of_Run_4363
    ****************************
     Run Number: 4363
     End of Run Comment:
    Run_type=Optics,target_type=LH2 15cm Loop3,beam_e0=2.839,beam_raster=on,leftarm_p=2.471,leftarm_theta=15,leftarm_colli=sieve,rightarm_p=2.522,rightarm_theta=15,rightarm_colli=out,comment_text=
     
    
    PRESCALE FACTORS:ps1=16777212   ps2=16777215   ps3=2   ps4=3   ps5=65535   ps6=65535   ps7=9999   ps8=65535   
    
    EVENTS   : 1300637      
    TIME     : 19.191 mins  
    
    DEAD TIME:   4.55%      
    
    TRIGGER RATES:   PRES/REAL
    T3:1164.4/2328.7 Hz   T4:19.1/57.2 Hz   T5: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T3:1340673/2681346  T4:  21964/65892    T5:      0/0        T8:     17/1179065  
    
    AVERAGE CURRENT
    BCM x1 : 9.7856 uA  BCM x3 : 9.7914 uA  BCM x10: 9.8720 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.01129        BCM u3 : 0.0113         BCM u10: 0.01138        
    
    BCM d1 : 0.01124        BCM d3 : 0.01125        BCM d10: 0.01135        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4363 at Thu Dec 20 07:00:02 EST 2007
    
    Wien angle : 6.19568
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 2.47071
    Left Arm arm angle : 14.9985
    Right Arm D1 momentum : 2.56505
    Right Arm arm angle : 15.0039
    HALLA:p : 2845.33
    HALLA:dpp : -0.00011377
    Tiefenbach Hall A energy : 2845.33
    Left Arm Top VDC Current : -2.24609
    Left Arm Bottom VDC Current : 2.00195
    Left Arm Q1 momentum : 2.47074
    Left Arm Q1 power supply : 1858.82
    Left Arm Q1 gauss meter : -0.15688
    Left Arm Q2 gauss meter : 0.5595
    Left Arm Q2 power supply current : 1063.83
    Left Arm Q2 momentum : 2.47057
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 847.728
    Left Arm D1 momentum : 2.47071
    Left Arm D1 NMR : 0.91444
    Left Arm Q3 gauss meter : -0.4981
    Left Arm Q3 power supply current : 983.506
    Left Arm Q3 momentum : 2.47038
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 2.57311
    Right Arm Q1 power supply : 1934.76
    Right Arm Q1 gauss meter : -0.04831
    Right Arm Q2 power supply current : 1107.55
    Right Arm Q2 momentum : 2.57349
    Right Arm Q2 gauss meter : 0.5796
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 935.641
    Right Arm D1 momentum : 2.56518
    Right Arm D1 NMR : 0.951961
    Right Arm Q3 power supply current : 1023.82
    Right Arm Q3 momentum : 2.57301
    Right Arm Q3 gauss meter : 0.4581
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 10.0442
    Current on Unser monitor : 22.7428
    Current on Upstream bcm : 10.0353
    Current on Downstream bcm : 10.0531
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 92.1609
    Hall C Current : 82.53
    MBSY1c magnet current (amp) : 118.639
    MBSY1c Bdl : 711246
    Hall A momentum (Tiefenbach) (HALLA:p) : 2845.36
    Hall A momentum orbit correction (dpp) : -0.000103636
    Hall A setup momentum (MMSHLAE) : 2839.38
    Hall A energy (halla_MeV) : 2845.36
    Hall C energy (hallc_MeV) : 3548.73
    Delta(E)/E width (MV_AI_DXWID) : 1.68039
    IPM1C12.XPOS : -0.169091
    IPM1H04A.XPOS : -1.98259
    IPM1H04A.YPOS : 0.0471936
    IPM1H04B.XPOS : -2.00311
    IPM1H04B.YPOS : 0.0207637
    Left Arm Collimator : 0.368506
    HacL_HPE1313A:0_Ch58 : -0.189453
    HacL_HPE1313A:0_Ch55 : 23.1445
    HacL_HPE1313A:0_Ch54 : 0.00683594
    SLI data valid? : Yes
    SLI horiz size mm : 0.229063
    SLI Energy spread *10^5 : 4.24191
    SLI x position : 1.59503
    SLI vert. size mm : 0.0805976
    SLI y position : 1.51737
    -----
    Target : L3 15cm
    fan frequency loop 1 : 59.5
    fan frequency loop 3 : 60
    Encoder position : 1.63491e+07
    Target type : 1.63491e+07
    temperature loop 1(1) : 7
    temperature loop 1(3) : 7.04
    Heat exchange He : 7.4
    temperature loop 3(1) : 18.81
    temperature loop 3(3) : 19
    Heat exchange H2 : 18.5
    HPH He loop 1 : 121.235
    HPH He loop 2 : 7.77332
    HPH H2 loop 3 : 438.559
    -----