Privacy and Security Notice
Main INDEX
Monthly INDEX
PREV
NEXT
User name a-onl
Log entry time 07:49:24 on December 20, 2007
Entry number 222395
keyword=End_of_Run_4367
****************************
Run Number: 4367
End of Run Comment:
Run_type=Test,target_type=LH2 15cm Loop3,beam_e0=2.839,beam_raster=on,leftarm_p=2.573,leftarm_theta=15,leftarm_colli=out,rightarm_p=2.573,rightarm_theta=15,rightarm_colli=out,comment_text=Boiling test 40 microamp
PRESCALE FACTORS:ps1=16777212 ps2=16777215 ps3=300 ps4=178 ps5=65535 ps6=65535 ps7=9999 ps8=65535
EVENTS : 363691
TIME : 5.020 mins
DEAD TIME: 1.87%
TRIGGER RATES: PRES/REAL
T3:1210.2/363065.2 Hz T4:20.4/3625.7 Hz T5: 0.0/0.0 Hz T8: 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T3: 364491/109347520 T4: 6134/1091978 T5: 0/0 T8: 4/308407
AVERAGE CURRENT
BCM x1 : 39.9794uA BCM x3 : 39.9787uA BCM x10: 37.6280uA
APPROXIMATE BCM CHARGES (C)
BCM u1 : 0.01209 BCM u3 : 0.0121 BCM u10: 0.01149
BCM d1 : 0.01199 BCM d3 : 0.01199 BCM d10: 0.01117
****************************
End-of-run EPICS data for Run Number 4367 at Thu Dec 20 07:49:21 EST 2007
Wien angle : 6.19568
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 2.57299
Left Arm arm angle : 14.9985
Right Arm D1 momentum : 2.57296
Right Arm arm angle : 15.0039
HALLA:p : 2846
HALLA:dpp : 0.000122644
Tiefenbach Hall A energy : 2846
Left Arm Top VDC Current : -21.3867
Left Arm Bottom VDC Current : -19.4824
Left Arm Q1 momentum : 2.57296
Left Arm Q1 power supply : 1935.72
Left Arm Q1 gauss meter : -0.16333
Left Arm Q2 gauss meter : 0.5825
Left Arm Q2 power supply current : 1108
Left Arm Q2 momentum : 2.57315
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 886.474
Left Arm D1 momentum : 2.57299
Left Arm D1 NMR : 0.952393
Left Arm Q3 gauss meter : -0.5187
Left Arm Q3 power supply current : 1024.28
Left Arm Q3 momentum : 2.57279
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 2.57311
Right Arm Q1 power supply : 1934.81
Right Arm Q1 gauss meter : -0.04831
Right Arm Q2 power supply current : 1107.55
Right Arm Q2 momentum : 2.5735
Right Arm Q2 gauss meter : 0.5796
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 909.246
Right Arm D1 momentum : 2.57296
Right Arm D1 NMR : 0.954795
Right Arm Q3 power supply current : 1023.82
Right Arm Q3 momentum : 2.57301
Right Arm Q3 gauss meter : 0.4581
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 40.4073
Current on Unser monitor : 53.1973
Current on Upstream bcm : 40.564
Current on Downstream bcm : 40.2505
Upstream Cavity Coefficient : 43.377
Downstream Cavity Coefficient : 42.913
Current on IBC0L02 (source) : 100.334
Hall C Current : 59.25
MBSY1c magnet current (amp) : 118.639
MBSY1c Bdl : 711246
Hall A momentum (Tiefenbach) (HALLA:p) : 2846.02
Hall A momentum orbit correction (dpp) : 0.000129498
Hall A setup momentum (MMSHLAE) : 2839.38
Hall A energy (halla_MeV) : 2846.02
Hall C energy (hallc_MeV) : 3548.83
Delta(E)/E width (MV_AI_DXWID) : 1.73471
IPM1C12.XPOS : -0.345822
IPM1H04A.XPOS : -1.99693
IPM1H04A.YPOS : 0.02298
IPM1H04B.XPOS : -2.00372
IPM1H04B.YPOS : -0.00847125
Left Arm Collimator : 0.871338
HacL_HPE1313A:0_Ch58 : -0.188965
HacL_HPE1313A:0_Ch55 : 23.0957
HacL_HPE1313A:0_Ch54 : 0.00683594
SLI data valid? : Yes
SLI horiz size mm : 0.238434
SLI Energy spread *10^5 : 4.41544
SLI x position : 1.59503
SLI vert. size mm : 0.0888307
SLI y position : 1.51737
-----
Target : L3 15cm
fan frequency loop 1 : 60
fan frequency loop 3 : 60
Encoder position : 1.63491e+07
Target type : 1.63491e+07
temperature loop 1(1) : 7
temperature loop 1(3) : 7.04
Heat exchange He : 7.4
temperature loop 3(1) : 18.7
temperature loop 3(3) : 19
Heat exchange H2 : 18.5
HPH He loop 1 : 108.236
HPH He loop 2 : 9.96235
HPH H2 loop 3 : 280.698
-----