Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 08:02:26 on December 20, 2007

    Entry number 222404

    keyword=End_of_Run_22215
    ****************************
     Run Number: 22215
     End of Run Comment:
    Run_type=Test,target_type=LH2 15cm Loop3,beam_e0=2.839,beam_raster=on,beam_halfwaveplate=out,leftarm_p=2.573,leftarm_theta=15,leftarm_colli=out,rightarm_p=2.573,rightarm_theta=15,rightarm_colli=out,comment_text=Boiling test 60 microamp
     
    
    PRESCALE FACTORS:ps1=417   ps2=700   ps3=16777215   ps4=16777215   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 159942       
    TIME     : 3.516 mins  
    
    DEAD TIME:   3.47%      
    
    TRIGGER RATES:   PRES/REAL
    T1:772.3/322037.1 Hz   T2:13.2/9206.4 Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1: 162909/67933164  T2:   2774/1942071  T8:      3/216011   
    
    AVERAGE CURRENT
    BCM x1 : 38.2081uA  BCM x3 : 38.1887uA  BCM x10: 22.1558uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.008102       BCM u3 : 0.008097       BCM u10: 0.003118       
    
    BCM d1 : 0.008018       BCM d3 : 0.008015       BCM d10: 0.006229       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 22215 at Thu Dec 20 08:02:23 EST 2007
    
    Wien angle : 6.19568
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 2.57299
    Left Arm arm angle : 14.9985
    Right Arm D1 momentum : 2.57292
    Right Arm arm angle : 15.0039
    HALLA:p : 2845.65
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 2845.65
    Left Arm Top VDC Current : -1.17188
    Left Arm Bottom VDC Current : 1.12305
    Left Arm Q1 momentum : 2.57303
    Left Arm Q1 power supply : 1935.72
    Left Arm Q1 gauss meter : -0.16333
    Left Arm Q2 gauss meter : 0.5826
    Left Arm Q2 power supply current : 1108
    Left Arm Q2 momentum : 2.57316
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 886.475
    Left Arm D1 momentum : 2.57299
    Left Arm D1 NMR : 0.952393
    Left Arm Q3 gauss meter : -0.5187
    Left Arm Q3 power supply current : 1024.28
    Left Arm Q3 momentum : 2.5728
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 2.57311
    Right Arm Q1 power supply : 1934.81
    Right Arm Q1 gauss meter : -0.04832
    Right Arm Q2 power supply current : 1107.55
    Right Arm Q2 momentum : 2.5735
    Right Arm Q2 gauss meter : 0.5796
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 909.277
    Right Arm D1 momentum : 2.57292
    Right Arm D1 NMR : 0.954781
    Right Arm Q3 power supply current : 1023.83
    Right Arm Q3 momentum : 2.57302
    Right Arm Q3 gauss meter : 0.4581
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 0.0233326
    Current on Unser monitor : 13.705
    Current on Upstream bcm : 0.0343583
    Current on Downstream bcm : 0.0123068
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 0.00603065
    Hall C Current : 0
    MBSY1c magnet current (amp) : 118.639
    MBSY1c Bdl : 711246
    Hall A momentum (Tiefenbach) (HALLA:p) : 2845.65
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 2839.38
    Hall A energy (halla_MeV) : 2845.65
    Hall C energy (hallc_MeV) : nan
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Left Arm Collimator : 0.87124
    HacL_HPE1313A:0_Ch58 : -0.189941
    HacL_HPE1313A:0_Ch55 : 23.0469
    HacL_HPE1313A:0_Ch54 : 0.00732422
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.59503
    SLI vert. size mm : 0
    SLI y position : 1.51737
    -----
    Target : L3 15cm
    Vacuum Pressure : 3.75869e-07
    fan frequency loop 1 : 59.5
    fan frequency loop 3 : 59.5
    Encoder position : 1.63491e+07
    Target type : 1.63491e+07
    temperature loop 1(1) : 7
    temperature loop 1(3) : 7.04
    Heat exchange He : 7.4
    temperature loop 3(1) : 18.84
    temperature loop 3(3) : 18.99
    Heat exchange H2 : 18.5
    HPH He loop 1 : 118.921
    HPH H2 loop 3 : 464.603