User name adev
Log entry time 10:11:02 on December 20, 2007
Entry number 222411
keyword=Start_Run_22216,Run_type=Cosmics,target_type=LH2 15cm Loop3,beam_e0=2.839,beam_raster=on,beam_halfwaveplate=out,leftarm_p=2.573,leftarm_theta=15,leftarm_colli=out,rightarm_p=2.573,rightarm_theta=15,rightarm_colli=out,comment_text=Cosmics Run ps8=1
Run Timestamp: Thu Dec 20 10:09:46 EST 2007
Beginning-of-run EPICS data for Run Number 22216 at Thu Dec 20 10:10:52 EST 2007
Run_type=Cosmics
target_type=LH2 15cm Loop3
beam_e0=2.839
beam_raster=on
beam_halfwaveplate=out
leftarm_p=2.573
leftarm_theta=15
leftarm_colli=out
rightarm_p=2.573
rightarm_theta=15
rightarm_colli=out
comment_text=Cosmics Run ps8=1
; RIGHT SPECTROMETER on adaql1/adev account.
; (Integer!) prescale factors for runs.
; This file is read at start of every run.
; Do NOT put spaces in string, NOR add 2nd string.
; Default factor is (2^24)-1 = 16.7M for ps1-4 and (2^16)-1 = 65K for ps5-8.
; T1 = main trigger S1.and.S2
; T2 = efficiency trigger (recommend to keep ~5 Hz)
; T8 = 1024 Hz pulser
; All other prescales should be maxed out.
ps1=65545,ps2=65535,ps3=16777215,ps4=16777215,ps5=65535,ps6=65535,ps7=65535,ps8=1
Left Arm Q1 momentum : 0.00228592
Left Arm Q1 power supply : 0
Left Arm Q1 gauss meter : 0.0001595
Left Arm Q2 power supply current : 0.0318934
Left Arm Q2 momentum : 0.00445349
Left Arm Q2 gauss meter : 0.0011864
Left Arm Q2 power supply polarity : enabled
Left Arm D1 power supply current : -1.4602
Left Arm D1 momentum : 0.0025666
Left Arm D1 NMR : 0.445476
Left Arm Q3 power supply current : 1.3826
Left Arm Q3 momentum : 0.00788602
Left Arm Q3 gauss meter : -0.0008157
Left Arm Q3 power supply polarity : disabled
Left Arm B Field Hall Probe (D-G) : -0.0009136
Right Arm Q1 momentum : 0.00263521
Right Arm Q1 power supply : 0
Right Arm Q1 gauss meter : -7.15e-05
Right Arm Q2 power supply current : -0.0107557
Right Arm Q2 momentum : -2.4992e-05
Right Arm Q2 gauss meter : 0.0005989
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 258.479
Right Arm D1 momentum : 0
Right Arm D1 NMR : 0.377012
Right Arm Q3 power supply current : 0.0828451
Right Arm Q3 momentum : 0.00351002
Right Arm Q3 gauss meter : 0.0003272
Right Arm Q3 power supply polarity : disabled
Right Arm B Field Hall Probe (D-G) : -0.3638
Left Arm Top VDC Current : -0.634766
Left Arm Bottom VDC Current : 2.68555
Left Arm Top VDC voltage : 2.61133
Left Arm Bottom VDC voltage : 2.52051
Right Arm Top VDC voltage : 2.74756
Right Arm Bottom VDC voltage : 2.67139
-----
Average current of the two cavities : 0.023355
Current on Unser monitor : 12.924
Current on Upstream bcm : 0.0342972
Current on Downstream bcm : 0.0124128
Upstream Cavity Coefficient : 43.377
Downstream Cavity Coefficient : 42.913
Current on IBC0L02 (source) : 0.00364304
Hall C Current : 0
Hall A momentum (Tiefenbach) (HALLA:p) : 2845.65
Hall A momentum orbit correction (dpp) : 0
Hall A setup momentum (MMSHLAE) : 2839.38
Hall A energy (halla_MeV) : 2845.65
Hall C energy (hallc_MeV) : nan
Delta(E)/E width (MV_AI_DXWID) : 0
MBSY1c magnet current (amp) : 0.0377198
MBSY1c Bdl : 711246
Arc1 dp/p : 0
Arc2 dp/p : 0
Left Arm Collimator : 0.871289
HacL_HPE1313A:0_Ch58 : -0.187988
HacL_HPE1313A:0_Ch55 : 22.998
HacL_HPE1313A:0_Ch54 : 0.00830078
Left Arm Angle Floor Angle : 15
Left Arm Angle Vernier : 30.8
Left Arm Scattering Angle : 14.9985
Right Arm Arm Collimator : 0.862939
HacR_HPE1313A:0_Ch58 : -0.621582
HacR_HPE1313A:0_Ch55 : 21.4355
HacR_HPE1313A:0_Ch54 : -0.970703
Right Arm Angle Floor Angle : 15
Right Arm Angle Vernier : -33.5
Right Arm Scattering Angle : 15.0039
-----
IPM1C12.XPOS : 0
IPM1C12.YPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Survey X offset bpmA : -0.63
Survey Y offset bpmA : -0.9
Survey X offset bpmB : 0.77
Survey Y offset bpmB : -1
-----
Wien angle : 6.19568
Helicity Mode ON/OFF Random/Toggle : OFF
Wien field : 4.0104
Laser attenuation Hall A : 100
Laser power Hall A : 100
Half-wave plate (off=out) : IN
rotating waveplate : 0
Beam Half-wave plate (off=out) : IN
Target : L3 15cm
Vacuum Pressure : 4.0458e-06
fan frequency loop 1 : 0
fan frequency loop 2 : 0
fan frequency loop 3 : 0
Encoder position : 1.63491e+07
Target type : 1.63491e+07
temperature loop 1(1) : 6.3
temperature loop 1(2) : 6.2
temperature loop 1(3) : 8.89
Heat exchange He : 10.7
temperature loop 3(1) : 25.9
temperature loop 3(2) : 23.57
temperature loop 3(3) : 27.65
Heat exchange H2 : 30.5
pressure loop He : 10.6447
pressure loop H2 before : 41.1826
pressure loop H2 return : 41.4755
HPH He loop 1 : 0.0669839
HPH He loop 2 : 0.00123869
HPH H2 loop 3 : 0.0170928
SLI data valid? : No
SLI horiz size mm : 0
SLI Energy spread *10^5 : 0
SLI x position : 2.8472
SLI vert. size mm : 0
SLI y position : 1.50986
Right S2 HV
S2 Slot1 ch0 : -2275
S2 Slot1 ch1 : -2120.7
S2 Slot1 ch2 : -2275.3
S2 Slot1 ch3 : -2050.6
S2 Slot1 ch4 : -2175.8
S2 Slot1 ch5 : -1990.2
S2 Slot1 ch6 : -2401.6
S2 Slot1 ch7 : -2451.9
S2 Slot1 ch8 : -2250.8
S2 Slot1 ch9 : -2451.1
S2 Slot1 ch10 : -2266.5
S2 Slot1 ch11 : -1996.3
-----
Right S1 HV
S1 Slot2 ch0 : -1720.9
S1 Slot2 ch1 : -1900.8
S1 Slot2 ch2 : -1750.7
S1 Slot2 ch3 : -1746.2
S1 Slot2 ch4 : -1697.7
S1 Slot2 ch5 : -2051
S1 Slot2 ch6 : -1811.4
S1 Slot2 ch7 : -1976.6
S1 Slot2 ch8 : -1827
S1 Slot2 ch9 : -1866.7
S1 Slot2 ch10 : -1876.6
S1 Slot2 ch11 : -1947.9
-----
Right Preshower HV
PS Slot4 ch0 : -976.2
PS Slot4 ch1 : -975.6
PS Slot4 ch2 : -975.9
PS Slot4 ch3 : -1001.5
PS Slot4 ch4 : -989
PS Slot4 ch5 : -988.7
PS Slot4 ch6 : -975.4
PS Slot4 ch7 : -960.9
PS Slot4 ch8 : -975.7
PS Slot4 ch9 : -976.3
PS Slot4 ch10 : -977
PS Slot4 ch11 : -975.9
PS Slot5 ch0 : -975.5
PS Slot5 ch1 : -937
PS Slot5 ch2 : -936.7
PS Slot5 ch3 : -975.5
PS Slot5 ch4 : -975.9
PS Slot5 ch5 : -975.3
PS Slot5 ch6 : -976.5
PS Slot5 ch7 : -976.2
PS Slot5 ch8 : -1061
PS Slot5 ch9 : -1002.5
PS Slot5 ch10 : -976.2
PS Slot5 ch11 : -976.6
PS Slot7 ch0 : -1098.1
PS Slot7 ch1 : -1008.1
PS Slot7 ch2 : -1001.9
PS Slot7 ch3 : -988.7
PS Slot7 ch4 : -989.5
PS Slot7 ch5 : -989.1
PS Slot7 ch6 : -989.5
PS Slot7 ch7 : -975.4
PS Slot7 ch8 : -975.8
PS Slot7 ch9 : -977.3
PS Slot7 ch10 : -989.4
PS Slot7 ch11 : -989.9
PS Slot8 ch0 : -811.2
PS Slot8 ch1 : -975.6
PS Slot8 ch2 : -975.2
PS Slot8 ch3 : -976
PS Slot8 ch4 : -1126.6
PS Slot8 ch5 : -1002.5
PS Slot8 ch6 : -989.9
PS Slot8 ch7 : -1096.4
PS Slot8 ch8 : -976.5
PS Slot8 ch9 : -1098.4
PS Slot8 ch10 : -975
PS Slot8 ch11 : -974.7
-----
Right Cerenkov HV
GCER Slot14 ch0 : -2466.6
GCER Slot14 ch1 : -2571.6
GCER Slot14 ch2 : -2586.2
GCER Slot14 ch3 : -2461.3
GCER Slot14 ch4 : -2525.1
GCER Slot14 ch5 : -2400.1
GCER Slot14 ch6 : -2545.5
GCER Slot14 ch7 : -2556.2
GCER Slot14 ch8 : -2501.5
GCER Slot14 ch9 : -2399.9
GCER Slot14 ch10 : -2201.2
GCER Slot14 ch11 : -2201.2
-----
Right Shower HV
SH Slot1 ch0 : -699.3
SH Slot1 ch1 : -698.9
SH Slot1 ch2 : -699.4
SH Slot1 ch3 : -700.4
SH Slot1 ch4 : -700
SH Slot1 ch5 : -700.3
SH Slot1 ch6 : -699.5
SH Slot1 ch7 : -701.3
SH Slot1 ch8 : -700.5
SH Slot1 ch9 : -700.6
SH Slot1 ch10 : -699.7
SH Slot1 ch11 : -700.4
SH Slot2 ch0 : -700.7
SH Slot2 ch1 : -700.2
SH Slot2 ch2 : -699.9
SH Slot2 ch3 : -9.3
SH Slot2 ch4 : -700.9
SH Slot2 ch5 : -701.3
SH Slot2 ch6 : -690.4
SH Slot2 ch7 : -634.4
SH Slot2 ch8 : -666.6
SH Slot2 ch9 : -635.1
SH Slot2 ch10 : -634.8
SH Slot2 ch11 : -666.1
SH Slot4 ch0 : -662
SH Slot4 ch1 : -658.8
SH Slot4 ch2 : -664
SH Slot4 ch3 : -705.2
SH Slot4 ch4 : -691
SH Slot4 ch5 : -665.5
SH Slot4 ch6 : -825.6
SH Slot4 ch7 : -8.7
SH Slot4 ch8 : -700.2
SH Slot4 ch9 : -683.5
SH Slot4 ch10 : -687.6
SH Slot4 ch11 : -633.3
SH Slot5 ch0 : -644.5
SH Slot5 ch1 : -654.9
SH Slot5 ch2 : -595.4
SH Slot5 ch3 : -608.6
SH Slot5 ch4 : -673.5
SH Slot5 ch5 : -602.8
SH Slot5 ch6 : -655.8
SH Slot5 ch7 : -650.9
SH Slot5 ch8 : -690.8
SH Slot5 ch9 : -679.4
SH Slot5 ch10 : -750.3
SH Slot5 ch11 : -10.1
SH Slot7 ch0 : -759.1
SH Slot7 ch1 : -698.7
SH Slot7 ch2 : -679
SH Slot7 ch3 : -684.5
SH Slot7 ch4 : -671.8
SH Slot7 ch5 : -668
SH Slot7 ch6 : -657.4
SH Slot7 ch7 : -650.8
SH Slot7 ch8 : -676.9
SH Slot7 ch9 : -694
SH Slot7 ch10 : -688.2
SH Slot7 ch11 : -704
SH Slot8 ch0 : -675.1
SH Slot8 ch1 : -722.1
SH Slot8 ch2 : -729.7
SH Slot8 ch3 : -7.6
SH Slot8 ch4 : -730.9
SH Slot8 ch5 : -705
SH Slot8 ch6 : -697.3
SH Slot8 ch7 : -716.4
SH Slot8 ch8 : -667.9
SH Slot8 ch9 : -676.4
SH Slot8 ch10 : -693.9
SH Slot8 ch11 : -672.7
SH Slot10 ch0 : -675.6
SH Slot10 ch1 : -702.2
SH Slot10 ch2 : -697.4
SH Slot10 ch3 : -715.3
SH Slot10 ch4 : -750
SH Slot10 ch5 : -850.4
SH Slot10 ch6 : -750
SH Slot10 ch7 : -10.4
SH Slot10 ch8 : -21.1
SH Slot10 ch9 : -21.3
SH Slot10 ch10 : -21.9
SH Slot10 ch11 : -18.9
-----