    keyword=End_of_Run_4370
    ****************************
     Run Number: 4370
     End of Run Comment:
    Run_type=Cosmics,target_type=LH2 15cm Loop3,beam_e0=2.839,beam_raster=on,leftarm_p=2.573,leftarm_theta=15,leftarm_colli=out,rightarm_p=2.573,rightarm_theta=15,rightarm_colli=out,comment_text=Cosmics Run  ps8=1
     
    
    PRESCALE FACTORS:ps1=16777212   ps2=16777215   ps3=65535   ps4=65535   ps5=65535   ps6=65535   ps7=9999   ps8=1   
    
    EVENTS   : 303167       
    TIME     : 5.001 mins  
    
    DEAD TIME:   1.32%      
    
    TRIGGER RATES:   PRES/REAL
    T3: 0.0/15.1 Hz   T4: 0.0/6.9  Hz   T5: 0.0/0.0  Hz   T8:1024.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T3:      0/4544     T4:      0/2081     T5:      0/0        T8: 307261/307261   
    
    AVERAGE CURRENT
    BCM x1 : -0.0009uA  BCM x3 : -0.0005uA  BCM x10: -0.0008uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : -1.079E-08     BCM u3 : 1.068E-07      BCM u10: 1.805E-07      
    
    BCM d1 : -5.571E-07     BCM d3 : -4.158E-07     BCM d10: -6.319E-07     
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 4370 at Thu Dec 20 10:14:54 EST 2007
    
    Wien angle : 6.19568
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.00255908
    Left Arm arm angle : 14.9985
    Right Arm D1 momentum : 0
    Right Arm arm angle : 15.0039
    HALLA:p : 2845.65
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 2845.65
    Left Arm Top VDC Current : -1.36719
    Left Arm Bottom VDC Current : 3.07617
    Left Arm Q1 momentum : 0.00198551
    Left Arm Q1 power supply : 0
    Left Arm Q1 gauss meter : 0.0001821
    Left Arm Q2 gauss meter : 0.0009809
    Left Arm Q2 power supply current : 0.0285165
    Left Arm Q2 momentum : 0.00364592
    Left Arm Q2 power supply polarity : enabled
    Left Arm D1 power supply current : -1.46185
    Left Arm D1 momentum : 0.00254962
    Left Arm D1 NMR : 0.196312
    Left Arm Q3 gauss meter : -0.0008076
    Left Arm Q3 power supply current : 1.38275
    Left Arm Q3 momentum : 0.00786851
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.00197243
    Right Arm Q1 power supply : 0
    Right Arm Q1 gauss meter : -5.72e-05
    Right Arm Q2 power supply current : -0.010985
    Right Arm Q2 momentum : -2.55246e-05
    Right Arm Q2 gauss meter : 0.000599
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 233.488
    Right Arm D1 momentum : 0
    Right Arm D1 NMR : 0.341287
    Right Arm Q3 power supply current : 0.0823071
    Right Arm Q3 momentum : 0.0035089
    Right Arm Q3 gauss meter : 0.0003269
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 0.0234958
    Current on Unser monitor : 12.9213
    Current on Upstream bcm : 0.0346193
    Current on Downstream bcm : 0.0123723
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 0.00313447
    Hall C Current : 0
    MBSY1c magnet current (amp) : 0.0377198
    MBSY1c Bdl : 711246
    Hall A momentum (Tiefenbach) (HALLA:p) : 2845.65
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 2839.38
    Hall A energy (halla_MeV) : 2845.65
    Hall C energy (hallc_MeV) : nan
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Left Arm Collimator : 0.871338
    HacL_HPE1313A:0_Ch58 : -0.188477
    HacL_HPE1313A:0_Ch55 : 22.9004
    HacL_HPE1313A:0_Ch54 : 0.00830078
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 2.57888
    SLI vert. size mm : 0
    SLI y position : 1.51737
    -----
    Target : L3 15cm
    fan frequency loop 1 : 0
    fan frequency loop 3 : 0
    Encoder position : 1.63491e+07
    Target type : 1.63491e+07
    temperature loop 1(1) : 6.75
    temperature loop 1(3) : 9.48
    Heat exchange He : 11.4
    temperature loop 3(1) : 29.85
    temperature loop 3(3) : 33.24
    Heat exchange H2 : 34.8
    HPH He loop 1 : 0.0813417
    HPH He loop 2 : 0.00123869
    HPH H2 loop 3 : 0.011068
    -----