Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 16:38:45 on January 30, 2008

    Entry number 228075

    keyword=End_of_Run_3657
    ****************************
     Run Number: 3657
     End of Run Comment:
    Run_type=Test,target_type=Carbon,beam_e0=0.956,beam_raster=on,leftarm_p=0.948,leftarm_theta=20.37,leftarm_colli=out,rightarm_p=0.948,rightarm_theta=19.00,rightarm_colli=out,comment_text=Lumi calibration run, Carbon, 5uA, setting raster
     
    
    PRESCALE FACTORS:can't read "psfacline": no such variable
        while executing
    "$w insert end "$psfacline..."
        (procedure "halla_scaler_process" line 303)
        invoked from within
    "halla_scaler_process .mid.tex scalerinfo "
    
    ****************************
    End-of-run EPICS data for Run Number 3657 at Wed Jan 30 16:38:42 EST 2008
    
    Wien angle : -46.0068
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.948013
    Left Arm arm angle : 20.37
    Right Arm D1 momentum : 0.947774
    Right Arm arm angle : 18.9999
    HALLA:p : 957.413
    HALLA:dpp : -9.44698e-05
    Tiefenbach Hall A energy : 957.414
    Left Arm Top VDC Current : -1.2207
    Left Arm Bottom VDC Current : 1.17188
    Left Arm Q1 momentum : 0.948117
    Left Arm Q1 power supply : 713.298
    Left Arm Q1 gauss meter : -0.06024
    Left Arm Q2 gauss meter : 0.16153
    Left Arm Q2 power supply current : 408.209
    Left Arm Q2 momentum : 0.948
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 314.684
    Left Arm D1 momentum : 0.948013
    Left Arm D1 NMR : 0.350996
    Left Arm Q3 gauss meter : -0.1913
    Left Arm Q3 power supply current : 377.468
    Left Arm Q3 momentum : 0.948129
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.947907
    Right Arm Q1 power supply : 712.711
    Right Arm Q1 gauss meter : -0.017965
    Right Arm Q2 power supply current : 408.024
    Right Arm Q2 momentum : 0.948084
    Right Arm Q2 gauss meter : 0.2137
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 323.746
    Right Arm D1 momentum : 0.947774
    Right Arm D1 NMR : 0.351708
    Right Arm Q3 power supply current : 377.117
    Right Arm Q3 momentum : 0.947748
    Right Arm Q3 gauss meter : 0.16864
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 5.43768
    Current on Unser monitor : 17.3472
    Current on Upstream bcm : 5.43391
    Current on Downstream bcm : 5.44146
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 5.43644
    Hall C Current : 0
    MBSY1c magnet current (amp) : 39.5773
    MBSY1c Bdl : 239056
    Hall A momentum (Tiefenbach) (HALLA:p) : 957.41
    Hall A momentum orbit correction (dpp) : -9.80863e-05
    Hall A setup momentum (MMSHLAE) : 960
    Hall A energy (halla_MeV) : 957.41
    Hall C energy (hallc_MeV) : 4592.01
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : -0.00586596
    IPM1H04A.XPOS : 0.0337136
    IPM1H04A.YPOS : 0.919333
    IPM1H04B.XPOS : 0.00119108
    IPM1H04B.YPOS : 1.00084
    Left Arm Collimator : 0.87168
    HacL_HPE1313A:0_Ch58 : -0.140137
    HacL_HPE1313A:0_Ch55 : 23.877
    HacL_HPE1313A:0_Ch54 : -0.134766
    SLI data valid? : Yes
    SLI horiz size mm : 0.0592234
    SLI Energy spread *10^5 : 1.48059
    SLI x position : 1.49068
    SLI vert. size mm : 0.391941
    SLI y position : 1.53239
    -----
    Target : Carbon
    fan frequency loop 1 : 0
    fan frequency loop 3 : 36
    Encoder position : 1.55287e+06
    Target type : 1.55287e+06
    temperature loop 1(1) : 109.81
    temperature loop 1(3) : 96.27
    Heat exchange He : 92.4
    temperature loop 3(1) : 19.2
    temperature loop 3(3) : 19.43
    Heat exchange H2 : 18.8
    HPH He loop 1 : 0.0813417
    HPH He loop 2 : 0.00710569
    HPH H2 loop 3 : 0.011068
    -----