    Log entry time 16:49:00 on January 30, 2008

    Entry number 228078

    keyword=End_of_Run_3658
    ****************************
     Run Number: 3658
     End of Run Comment:
    Run_type=Test,target_type=Carbon,beam_e0=0.956,beam_raster=on,leftarm_p=0.948,leftarm_theta=20.37,leftarm_colli=out,rightarm_p=0.948,rightarm_theta=19.00,rightarm_colli=out,comment_text=Lumi calibration run, Carbon, 5uA, setting raster
     
    
    PRESCALE FACTORS:ps1=1   ps2=1   ps3=1001   ps4=1   ps5=99999   ps6=65535   ps7=65535   ps8=50   
    
    EVENTS   : 2569481      
    TIME     : 9.583 mins  
    
    DEAD TIME:  73.93%      
    
    TRIGGER RATES:   PRES/REAL
    T1:6412.4/6412.4 Hz   T2:10614.7/10614.7 Hz   T3: 0.0/0.0  Hz   T4:97.3/97.3 Hz   T5: 0.0/0.0  Hz   T6: 0.0/0.0  Hz   T8:20.5/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:3687039/3687039  T2:6103310/6103310  T3:      0/0        T4:  55944/55944    T5:      0/0        T6:      0/0        T8:  11775/588784   
    
    AVERAGE CURRENT
    BCM x1 : 5.4356 uA  BCM x3 : 5.4402 uA  BCM x10: 5.4847 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.003121       BCM u3 : 0.003123       BCM u10: 0.003146       
    
    BCM d1 : 0.00313        BCM d3 : 0.003133       BCM d10: 0.003161       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3658 at Wed Jan 30 16:48:57 EST 2008
    
    Wien angle : -46.0068
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.948012
    Left Arm arm angle : 20.37
    Right Arm D1 momentum : 0.948002
    Right Arm arm angle : 18.9999
    HALLA:p : 957.41
    HALLA:dpp : -9.80294e-05
    Tiefenbach Hall A energy : 957.41
    Left Arm Top VDC Current : -2.05078
    Left Arm Bottom VDC Current : -0.927734
    Left Arm Q1 momentum : 0.948046
    Left Arm Q1 power supply : 713.298
    Left Arm Q1 gauss meter : -0.06024
    Left Arm Q2 gauss meter : 0.1615
    Left Arm Q2 power supply current : 408.206
    Left Arm Q2 momentum : 0.947993
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 314.683
    Left Arm D1 momentum : 0.948012
    Left Arm D1 NMR : 0.350996
    Left Arm Q3 gauss meter : -0.1913
    Left Arm Q3 power supply current : 377.469
    Left Arm Q3 momentum : 0.948134
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.947836
    Right Arm Q1 power supply : 712.711
    Right Arm Q1 gauss meter : -0.017978
    Right Arm Q2 power supply current : 408.025
    Right Arm Q2 momentum : 0.948084
    Right Arm Q2 gauss meter : 0.2138
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 324.205
    Right Arm D1 momentum : 0.948002
    Right Arm D1 NMR : 0.351792
    Right Arm Q3 power supply current : 377.119
    Right Arm Q3 momentum : 0.947753
    Right Arm Q3 gauss meter : 0.16863
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 5.45087
    Current on Unser monitor : 18.1247
    Current on Upstream bcm : 5.4587
    Current on Downstream bcm : 5.44305
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 5.4452
    Hall C Current : 0
    MBSY1c magnet current (amp) : 39.5773
    MBSY1c Bdl : 239056
    Hall A momentum (Tiefenbach) (HALLA:p) : 957.413
    Hall A momentum orbit correction (dpp) : -9.5048e-05
    Hall A setup momentum (MMSHLAE) : 960
    Hall A energy (halla_MeV) : 957.413
    Hall C energy (hallc_MeV) : 4592.01
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0.00352424
    IPM1H04A.XPOS : 0.0328545
    IPM1H04A.YPOS : 0.927533
    IPM1H04B.XPOS : -0.0123553
    IPM1H04B.YPOS : 0.995692
    Left Arm Collimator : 0.871729
    HacL_HPE1313A:0_Ch58 : -0.141113
    HacL_HPE1313A:0_Ch55 : 23.877
    HacL_HPE1313A:0_Ch54 : -0.134766
    SLI data valid? : Yes
    SLI horiz size mm : 0.263497
    SLI Energy spread *10^5 : 6.58741
    SLI x position : 1.72919
    SLI vert. size mm : 0.149489
    SLI y position : 1.53239
    -----
    Target : Carbon
    fan frequency loop 1 : 0
    fan frequency loop 3 : 36
    Encoder position : 1.55287e+06
    Target type : 1.55287e+06
    temperature loop 1(1) : 109.82
    temperature loop 1(3) : 96.21
    Heat exchange He : 92.4
    temperature loop 3(1) : 19.28
    temperature loop 3(3) : 19.52
    Heat exchange H2 : 18.9
    HPH He loop 1 : 0.0669839
    HPH He loop 2 : 0.00710569
    HPH H2 loop 3 : 0.00634721
    -----