     Run Number: 3660
     End of Run Comment:
    Run_type=Test,target_type=Carbon,beam_e0=0.956,beam_raster=on,leftarm_p=0.948,leftarm_theta=20.37,leftarm_colli=out,rightarm_p=0.948,rightarm_theta=19.00,rightarm_colli=out,comment_text=Lumi calibration run, Carbon, 5uA, setting raster
     
    
    PRESCALE FACTORS:ps1=1   ps2=1   ps3=1001   ps4=1   ps5=99999   ps6=65535   ps7=65535   ps8=50   
    
    EVENTS   : 1614058      
    TIME     : 7.178 mins  
    
    DEAD TIME:  77.69%      
    
    TRIGGER RATES:   PRES/REAL
    T1:6962.6/6962.6 Hz   T2:9740.9/9740.9 Hz   T3: 0.0/0.0  Hz   T4:73.6/73.6 Hz   T5: 0.0/0.0  Hz   T6: 0.0/0.0  Hz   T8:20.5/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:2998481/2998481  T2:4195000/4195000  T3:      0/0        T4:  31703/31703    T5:      0/0        T6:      0/0        T8:   8819/440993   
    
    AVERAGE CURRENT
    BCM x1 : 5.9526 uA  BCM x3 : 5.9567 uA  BCM x10: 6.0045 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.00256        BCM u3 : 0.002561       BCM u10: 0.00258        
    
    BCM d1 : 0.002567       BCM d3 : 0.002569       BCM d10: 0.002591       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3660 at Wed Jan 30 17:00:35 EST 2008
    
    Wien angle : -46.0068
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.948013
    Left Arm arm angle : 20.37
    Right Arm D1 momentum : 0.948031
    Right Arm arm angle : 18.9999
    HALLA:p : 957.406
    HALLA:dpp : -0.00010222
    Tiefenbach Hall A energy : 957.406
    Left Arm Top VDC Current : 2.09961
    Left Arm Bottom VDC Current : 3.90625
    Left Arm Q1 momentum : 0.948117
    Left Arm Q1 power supply : 713.298
    Left Arm Q1 gauss meter : -0.06024
    Left Arm Q2 gauss meter : 0.16152
    Left Arm Q2 power supply current : 408.207
    Left Arm Q2 momentum : 0.947996
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 314.688
    Left Arm D1 momentum : 0.948013
    Left Arm D1 NMR : 0.350996
    Left Arm Q3 gauss meter : -0.19131
    Left Arm Q3 power supply current : 377.472
    Left Arm Q3 momentum : 0.948139
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.947836
    Right Arm Q1 power supply : 712.711
    Right Arm Q1 gauss meter : -0.01797
    Right Arm Q2 power supply current : 408.027
    Right Arm Q2 momentum : 0.948089
    Right Arm Q2 gauss meter : 0.2138
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 324.135
    Right Arm D1 momentum : 0.948031
    Right Arm D1 NMR : 0.351803
    Right Arm Q3 power supply current : 377.121
    Right Arm Q3 momentum : 0.947757
    Right Arm Q3 gauss meter : 0.16864
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 5.1094
    Current on Unser monitor : 17.3463
    Current on Upstream bcm : 5.11739
    Current on Downstream bcm : 5.10141
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 5.07591
    Hall C Current : 0
    MBSY1c magnet current (amp) : 39.5773
    MBSY1c Bdl : 239056
    Hall A momentum (Tiefenbach) (HALLA:p) : 957.405
    Hall A momentum orbit correction (dpp) : -0.000103361
    Hall A setup momentum (MMSHLAE) : 960
    Hall A energy (halla_MeV) : 957.405
    Hall C energy (hallc_MeV) : 4592.01
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : -0.00587174
    IPM1H04A.XPOS : 0.0609866
    IPM1H04A.YPOS : 0.953314
    IPM1H04B.XPOS : 0.0272012
    IPM1H04B.YPOS : 1.02383
    Left Arm Collimator : 0.87168
    HacL_HPE1313A:0_Ch58 : -0.140625
    HacL_HPE1313A:0_Ch55 : 23.9258
    HacL_HPE1313A:0_Ch54 : -0.135254
    SLI data valid? : Yes
    SLI horiz size mm : 0.152
    SLI Energy spread *10^5 : 3.8
    SLI x position : 1.71429
    SLI vert. size mm : 0.145416
    SLI y position : 1.52488
    -----
    Target : Carbon
    fan frequency loop 1 : 0
    fan frequency loop 3 : 36
    Encoder position : 1.55287e+06
    Target type : 1.55287e+06
    temperature loop 1(1) : 109.82
    temperature loop 1(3) : 96.13
    Heat exchange He : 92.4
    temperature loop 3(1) : 19.34
    temperature loop 3(3) : 19.58
    Heat exchange H2 : 19
    HPH He loop 1 : 0.0970926
    HPH He loop 2 : 0.00356948
    HPH H2 loop 3 : 0.00634721
    -----