NEXT
User name a-onl
Log entry time 17:09:07 on January 30, 2008
Entry number 228087
keyword=End_of_Run_3662
****************************
Run Number: 3662
End of Run Comment:
Run_type=Test,target_type=Carbon,beam_e0=0.956,beam_raster=on,leftarm_p=0.948,leftarm_theta=20.37,leftarm_colli=out,rightarm_p=0.948,rightarm_theta=19.00,rightarm_colli=out,comment_text=Lumi calibration run, Carbon, 5uA, setting raster
PRESCALE FACTORS:ps1=1 ps2=1 ps3=1001 ps4=1 ps5=99999 ps6=65535 ps7=65535 ps8=50
EVENTS : 868825
TIME : 4.268 mins
DEAD TIME: 70.88%
TRIGGER RATES: PRES/REAL
T1:4841.1/4841.1 Hz T2:6739.9/6739.9 Hz T3: 0.0/0.0 Hz T4:50.8/50.8 Hz T5: 0.0/0.0 Hz T6: 0.0/0.0 Hz T8:20.5/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1:1239641/1239641 T2:1725863/1725863 T3: 0/0 T4: 13013/13013 T5: 0/0 T6: 0/0 T8: 5244/262211
AVERAGE CURRENT
BCM x1 : 4.1555 uA BCM x3 : 4.1592 uA BCM x10: 4.1933 uA
APPROXIMATE BCM CHARGES (C)
BCM u1 : 0.001062 BCM u3 : 0.001063 BCM u10: 0.001071
BCM d1 : 0.001066 BCM d3 : 0.001067 BCM d10: 0.001076
****************************
End-of-run EPICS data for Run Number 3662 at Wed Jan 30 17:09:03 EST 2008
Wien angle : -46.0068
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.948012
Left Arm arm angle : 20.37
Right Arm D1 momentum : 0.948022
Right Arm arm angle : 18.9999
HALLA:p : 957.407
HALLA:dpp : -0.000100782
Tiefenbach Hall A energy : 957.408
Left Arm Top VDC Current : 4.19922
Left Arm Bottom VDC Current : -0.830078
Left Arm Q1 momentum : 0.948046
Left Arm Q1 power supply : 713.245
Left Arm Q1 gauss meter : -0.06024
Left Arm Q2 gauss meter : 0.16151
Left Arm Q2 power supply current : 408.206
Left Arm Q2 momentum : 0.947993
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 314.687
Left Arm D1 momentum : 0.948012
Left Arm D1 NMR : 0.350996
Left Arm Q3 gauss meter : -0.19131
Left Arm Q3 power supply current : 377.471
Left Arm Q3 momentum : 0.948136
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 0.947836
Right Arm Q1 power supply : 712.711
Right Arm Q1 gauss meter : -0.01799
Right Arm Q2 power supply current : 408.025
Right Arm Q2 momentum : 0.948086
Right Arm Q2 gauss meter : 0.2137
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 324.121
Right Arm D1 momentum : 0.948022
Right Arm D1 NMR : 0.3518
Right Arm Q3 power supply current : 377.12
Right Arm Q3 momentum : 0.947755
Right Arm Q3 gauss meter : 0.16863
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 5.15946
Current on Unser monitor : 17.7104
Current on Upstream bcm : 5.15365
Current on Downstream bcm : 5.16528
Upstream Cavity Coefficient : 43.377
Downstream Cavity Coefficient : 42.913
Current on IBC0L02 (source) : 5.13883
Hall C Current : 0
MBSY1c magnet current (amp) : 39.5773
MBSY1c Bdl : 239056
Hall A momentum (Tiefenbach) (HALLA:p) : 957.405
Hall A momentum orbit correction (dpp) : -0.00010349
Hall A setup momentum (MMSHLAE) : 960
Hall A energy (halla_MeV) : 957.405
Hall C energy (hallc_MeV) : 4592.01
Delta(E)/E width (MV_AI_DXWID) : 0
IPM1C12.XPOS : 0.00207937
IPM1H04A.XPOS : 0.0249643
IPM1H04A.YPOS : 0.931032
IPM1H04B.XPOS : 0.000835955
IPM1H04B.YPOS : 1.00529
Left Arm Collimator : 0.87168
HacL_HPE1313A:0_Ch58 : -0.141113
HacL_HPE1313A:0_Ch55 : 23.877
HacL_HPE1313A:0_Ch54 : -0.135254
SLI data valid? : Yes
SLI horiz size mm : 0.419828
SLI Energy spread *10^5 : 10.4957
SLI x position : 1.71429
SLI vert. size mm : 0.20296
SLI y position : 1.53239
-----
Target : Carbon
fan frequency loop 1 : 0
fan frequency loop 3 : 37
Encoder position : 1.55287e+06
Target type : 1.55287e+06
temperature loop 1(1) : 109.81
temperature loop 1(3) : 96.28
Heat exchange He : 92.4
temperature loop 3(1) : 19.41
temperature loop 3(3) : 19.64
Heat exchange H2 : 19.1
HPH He loop 1 : 0.0813417
HPH He loop 2 : 0.00710569
HPH H2 loop 3 : 0.011068
-----