Run Number: 3663
End of Run Comment:
Run_type=Test,target_type=Carbon,beam_e0=0.956,beam_raster=on,leftarm_p=0.948,leftarm_theta=20.37,leftarm_colli=out,rightarm_p=0.948,rightarm_theta=19.00,rightarm_colli=out,comment_text=Lumi calibration run, Carbon, 50uA
PRESCALE FACTORS:ps1=1 ps2=1 ps3=1001 ps4=1 ps5=99999 ps6=65535 ps7=65535 ps8=50
EVENTS : 21513801
TIME : 73.105 mins
DEAD TIME: 92.27%
TRIGGER RATES: PRES/REAL
T1:26382.1/26382.1 Hz T2:36792.5/36792.5 Hz T3: 0.0/0.0 Hz T4:278.5/278.5 Hz T5: 0.0/0.0 Hz T6: 0.0/0.0 Hz T8:20.5/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1:115720098/115720098 T2:161383343/161383343 T3: 0/0 T4:1221585/1221585 T5: 0/0 T6: 0/0 T8: 89831/4491588
AVERAGE CURRENT
BCM x1 : 22.7780uA BCM x3 : 22.7741uA BCM x10: 20.0102uA
APPROXIMATE BCM CHARGES (C)
BCM u1 : 0.09973 BCM u3 : 0.09973 BCM u10: 0.08778
BCM d1 : 0.1001 BCM d3 : 0.1001 BCM d10: 0.08776
****************************
End-of-run EPICS data for Run Number 3663 at Wed Jan 30 18:22:44 EST 2008
Wien angle : -46.0068
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.948012
Left Arm arm angle : 20.37
Right Arm D1 momentum : 0.948015
Right Arm arm angle : 18.9999
HALLA:p : 957.463
HALLA:dpp : -4.25895e-05
Tiefenbach Hall A energy : 957.463
Left Arm Top VDC Current : 1.80664
Left Arm Bottom VDC Current : 1.17188
Left Arm Q1 momentum : 0.948046
Left Arm Q1 power supply : 713.298
Left Arm Q1 gauss meter : -0.06024
Left Arm Q2 gauss meter : 0.1615
Left Arm Q2 power supply current : 408.21
Left Arm Q2 momentum : 0.948003
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 314.693
Left Arm D1 momentum : 0.948012
Left Arm D1 NMR : 0.350996
Left Arm Q3 gauss meter : -0.19131
Left Arm Q3 power supply current : 377.489
Left Arm Q3 momentum : 0.948182
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 0.947907
Right Arm Q1 power supply : 712.764
Right Arm Q1 gauss meter : -0.017979
Right Arm Q2 power supply current : 408.028
Right Arm Q2 momentum : 0.948093
Right Arm Q2 gauss meter : 0.2137
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 324.121
Right Arm D1 momentum : 0.948015
Right Arm D1 NMR : 0.351797
Right Arm Q3 power supply current : 377.13
Right Arm Q3 momentum : 0.94778
Right Arm Q3 gauss meter : 0.16864
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 5.00479
Current on Unser monitor : 16.5988
Current on Upstream bcm : 5.00429
Current on Downstream bcm : 5.00529
Upstream Cavity Coefficient : 43.377
Downstream Cavity Coefficient : 42.913
Current on IBC0L02 (source) : 5.00166
Hall C Current : 0
MBSY1c magnet current (amp) : 39.5773
MBSY1c Bdl : 239056
Hall A momentum (Tiefenbach) (HALLA:p) : 957.463
Hall A momentum orbit correction (dpp) : -4.24645e-05
Hall A setup momentum (MMSHLAE) : 960
Hall A energy (halla_MeV) : 957.464
Hall C energy (hallc_MeV) : 4592.01
Delta(E)/E width (MV_AI_DXWID) : 0
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0.00876349
IPM1H04A.YPOS : 0.948641
IPM1H04B.XPOS : 0.00339293
IPM1H04B.YPOS : 1.05981
Left Arm Collimator : 0.871631
HacL_HPE1313A:0_Ch58 : -0.141113
HacL_HPE1313A:0_Ch55 : 23.877
HacL_HPE1313A:0_Ch54 : -0.134766
SLI data valid? : Yes
SLI horiz size mm : 0.121306
SLI Energy spread *10^5 : 3.03264
SLI x position : 1.50559
SLI vert. size mm : 0.119627
SLI y position : 1.53239
-----
Target : Thin Pb Slant
fan frequency loop 1 : 0
fan frequency loop 3 : 36
Encoder position : 7.97588e+06
Target type : 7.97588e+06
temperature loop 1(1) : 109.92
temperature loop 1(3) : 96.39
Heat exchange He : 92.7
temperature loop 3(1) : 19.55
temperature loop 3(3) : 19.79
Heat exchange H2 : 19.2
HPH He loop 1 : 0.0669839
HPH He loop 2 : 0.0118473
HPH H2 loop 3 : 0.00634721
-----