Entry number 228097
keyword=End_of_Run_6020
****************************
Run Number: 6020
End of Run Comment:
Run_type=Production,target_type=Iron 50 degs Right,beam_e0=0.9574,beam_raster=on,beam_halfwaveplate=out,leftarm_p=0.948,leftarm_theta=20.37,leftarm_colli=out,rightarm_p=0.948,rightarm_theta=19,rightarm_colli=out,comment_text=Thin lead Jan-30-2008-100V.txt
PRESCALE FACTORS:ps1=9999 ps2=9999 ps3=1 ps4=5 ps5=65535 ps6=65535 ps7=65535 ps8=65535
EVENTS : 34315
TIME : 7.247 mins
DEAD TIME: 96.52%
TRIGGER RATES: PRES/REAL
T1: 0.3/3190.4 Hz T2: 0.0/0.0 Hz T3:2253.3/2253.3 Hz T4:17.5/87.8 Hz T5: 0.0/0.0 Hz T6: 0.0/78.9 Hz T7: 0.0/0.0 Hz T8: 0.0/1024.0 Hz T9: 0.0/0.0 Hz
TRIGGER TOTALS: PRES/REAL
T1: 138/1387175 T2: 0/0 T3: 979732/979732 T4: 7630/38153 T5: 0/0 T6: 0/34315 T7: 0/0 T8: 6/445226 T9: 0/0
AVERAGE CURRENT
BCM x1 : 1.0893 uA BCM x3 : 1.0908 uA BCM x10: 1.0967 uA
APPROXIMATE BCM CHARGES (C)
BCM u1 : 0.000473 BCM u3 : 0.0004732 BCM u10: 0.0004767
BCM d1 : 0.0004742 BCM d3 : 0.0004754 BCM d10: 0.000477
****************************
End-of-run EPICS data for Run Number 6020 at Wed Jan 30 18:45:41 EST 2008
Wien angle : -46.0068
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.948012
Left Arm arm angle : 20.37
Right Arm D1 momentum : 0.948014
Right Arm arm angle : 18.9999
HALLA:p : 957.504
HALLA:dpp : 0
Tiefenbach Hall A energy : 957.504
Left Arm Top VDC Current : -1.5625
Left Arm Bottom VDC Current : -1.41602
Left Arm Q1 momentum : 0.948117
Left Arm Q1 power supply : 713.298
Left Arm Q1 gauss meter : -0.06026
Left Arm Q2 gauss meter : 0.16151
Left Arm Q2 power supply current : 408.21
Left Arm Q2 momentum : 0.948003
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 314.692
Left Arm D1 momentum : 0.948012
Left Arm D1 NMR : 0.350996
Left Arm Q3 gauss meter : -0.19131
Left Arm Q3 power supply current : 377.485
Left Arm Q3 momentum : 0.948172
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 0.947836
Right Arm Q1 power supply : 712.711
Right Arm Q1 gauss meter : -0.017974
Right Arm Q2 power supply current : 408.028
Right Arm Q2 momentum : 0.948092
Right Arm Q2 gauss meter : 0.2138
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 324.12
Right Arm D1 momentum : 0.948014
Right Arm D1 NMR : 0.351797
Right Arm Q3 power supply current : 377.126
Right Arm Q3 momentum : 0.94777
Right Arm Q3 gauss meter : 0.16864
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 0.0242498
Current on Unser monitor : 12.1936
Current on Upstream bcm : 0.0359575
Current on Downstream bcm : 0.0125421
Upstream Cavity Coefficient : 43.377
Downstream Cavity Coefficient : 42.913
Current on IBC0L02 (source) : 0.502706
Hall C Current : 0
MBSY1c magnet current (amp) : 39.5773
MBSY1c Bdl : 239056
Hall A momentum (Tiefenbach) (HALLA:p) : 957.504
Hall A momentum orbit correction (dpp) : 0
Hall A setup momentum (MMSHLAE) : 960
Hall A energy (halla_MeV) : 957.504
Hall C energy (hallc_MeV) : 4592.01
Delta(E)/E width (MV_AI_DXWID) : 0
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Left Arm Collimator : 0.871631
HacL_HPE1313A:0_Ch58 : -0.140625
HacL_HPE1313A:0_Ch55 : 23.877
HacL_HPE1313A:0_Ch54 : -0.134766
-----
SLI data valid? : No
SLI horiz size mm : 0
SLI Energy spread *10^5 : 0
SLI x position : 2.21366
SLI vert. size mm : 0
SLI y position : 2.11831
-----
Target : Thin Pb Slant
Vacuum Pressure : 3.68546e-07
fan frequency loop 1 : 0
fan frequency loop 3 : 36
Encoder position : 7.97588e+06
Target type : 7.97588e+06
temperature loop 1(1) : 109.87
temperature loop 1(3) : 96.58
Heat exchange He : 92.7
temperature loop 3(1) : 19.5
temperature loop 3(3) : 19.73
Heat exchange H2 : 19.2
HPH He loop 1 : 0.0813417
HPH H2 loop 3 : 0.011068