Entry number 228100
keyword=End_of_Run_6021
****************************
Run Number: 6021
End of Run Comment:
Run_type=Production,target_type=Iron 50 degs Right,beam_e0=0.9574,beam_raster=on,beam_halfwaveplate=out,leftarm_p=0.948,leftarm_theta=20.37,leftarm_colli=out,rightarm_p=0.948,rightarm_theta=19,rightarm_colli=out,comment_text=Thin lead Jan-30-2008-100V.txt
PRESCALE FACTORS:ps1=9999 ps2=9999 ps3=1 ps4=5 ps5=65535 ps6=65535 ps7=65535 ps8=65535
EVENTS : 277459
TIME : 13.811 mins
DEAD TIME: 96.84%
TRIGGER RATES: PRES/REAL
T1: 1.5/14937.0 Hz T2: 0.0/0.0 Hz T3:10527.6/10527.6 Hz T4:74.3/371.4 Hz T5: 0.0/0.0 Hz T6: 0.0/334.8 Hz T7: 0.0/0.0 Hz T8: 0.0/1024.0 Hz T9: 0.0/0.0 Hz
TRIGGER TOTALS: PRES/REAL
T1: 1237/12377692 T2: 0/0 T3:8723794/8723794 T4: 61545/307729 T5: 0/0 T6: 4/277459 T7: 0/0 T8: 12/848549 T9: 0/0
AVERAGE CURRENT
BCM x1 : 5.1225 uA BCM x3 : 5.1284 uA BCM x10: 5.1566 uA
APPROXIMATE BCM CHARGES (C)
BCM u1 : 0.004238 BCM u3 : 0.004239 BCM u10: 0.004268
BCM d1 : 0.004251 BCM d3 : 0.004261 BCM d10: 0.004279
****************************
End-of-run EPICS data for Run Number 6021 at Wed Jan 30 19:03:18 EST 2008
Wien angle : -46.0068
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.948012
Left Arm arm angle : 20.37
Right Arm D1 momentum : 0.948015
Right Arm arm angle : 18.9999
HALLA:p : 957.412
HALLA:dpp : -9.6526e-05
Tiefenbach Hall A energy : 957.412
Left Arm Top VDC Current : 0.537109
Left Arm Bottom VDC Current : 3.17383
Left Arm Q1 momentum : 0.948117
Left Arm Q1 power supply : 713.245
Left Arm Q1 gauss meter : -0.06024
Left Arm Q2 gauss meter : 0.16148
Left Arm Q2 power supply current : 408.209
Left Arm Q2 momentum : 0.948002
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 314.692
Left Arm D1 momentum : 0.948012
Left Arm D1 NMR : 0.350996
Left Arm Q3 gauss meter : -0.19132
Left Arm Q3 power supply current : 377.486
Left Arm Q3 momentum : 0.948173
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 0.947836
Right Arm Q1 power supply : 712.764
Right Arm Q1 gauss meter : -0.017976
Right Arm Q2 power supply current : 408.028
Right Arm Q2 momentum : 0.948094
Right Arm Q2 gauss meter : 0.2138
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 324.12
Right Arm D1 momentum : 0.948014
Right Arm D1 NMR : 0.351797
Right Arm Q3 power supply current : 377.128
Right Arm Q3 momentum : 0.947773
Right Arm Q3 gauss meter : 0.16864
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 5.10496
Current on Unser monitor : 17.2814
Current on Upstream bcm : 5.11478
Current on Downstream bcm : 5.09514
Upstream Cavity Coefficient : 43.377
Downstream Cavity Coefficient : 42.913
Current on IBC0L02 (source) : 5.09054
Hall C Current : 0
MBSY1c magnet current (amp) : 39.5773
MBSY1c Bdl : 239056
Hall A momentum (Tiefenbach) (HALLA:p) : 957.406
Hall A momentum orbit correction (dpp) : -0.000102079
Hall A setup momentum (MMSHLAE) : 960
Hall A energy (halla_MeV) : 957.406
Hall C energy (hallc_MeV) : 4592.01
Delta(E)/E width (MV_AI_DXWID) : 0
IPM1C12.XPOS : 0.00626159
IPM1H04A.XPOS : 0.0192021
IPM1H04A.YPOS : 0.934164
IPM1H04B.XPOS : 0.0112237
IPM1H04B.YPOS : 0.999926
Left Arm Collimator : 0.871729
HacL_HPE1313A:0_Ch58 : -0.140625
HacL_HPE1313A:0_Ch55 : 23.877
HacL_HPE1313A:0_Ch54 : -0.134277
-----
SLI data valid? : Yes
SLI horiz size mm : 0.139891
SLI Energy spread *10^5 : 3.49727
SLI x position : 1.49814
SLI vert. size mm : 0.399327
SLI y position : 1.52488
-----
Target : Thin Pb Slant
Vacuum Pressure : 4.10234e-07
fan frequency loop 1 : 0
fan frequency loop 3 : 35.5
Encoder position : 7.97588e+06
Target type : 7.97588e+06
temperature loop 1(1) : 109.84
temperature loop 1(3) : 96.64
Heat exchange He : 92.8
temperature loop 3(1) : 19.45
temperature loop 3(3) : 19.68
Heat exchange H2 : 19.1
HPH He loop 1 : 0.0669839