    User name a-onl

    Log entry time 19:10:25 on January 30, 2008

    Entry number 228104

    keyword=End_of_Run_3665
    ****************************
     Run Number: 3665
     End of Run Comment:
    Run_type=Test,target_type=Tantalum,beam_e0=0.956,beam_raster=on,leftarm_p=0.948,leftarm_theta=20.37,leftarm_colli=out,rightarm_p=0.948,rightarm_theta=19.00,rightarm_colli=out,comment_text=Tantalum, 1uA, setting rates
     
    
    PRESCALE FACTORS:ps1=1   ps2=1   ps3=1001   ps4=1   ps5=99999   ps6=65535   ps7=65535   ps8=50   
    
    EVENTS   : 32263        
    TIME     : 2.918 mins  
    
    DEAD TIME:  27.10%      
    
    TRIGGER RATES:   PRES/REAL
    T1:74.8/74.8 Hz   T2:156.8/156.8 Hz   T3: 0.0/0.0  Hz   T4: 0.8/0.8  Hz   T5: 0.0/0.0  Hz   T6: 0.0/0.0  Hz   T8:20.5/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:  13086/13086    T2:  27452/27452    T3:      0/0        T4:    138/138      T5:      0/0        T6:      0/0        T8:   3585/179263   
    
    AVERAGE CURRENT
    BCM x1 : 0.3713 uA  BCM x3 : 0.3724 uA  BCM x10: 0.3755 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 6.481E-05      BCM u3 : 6.496E-05      BCM u10: 6.558E-05      
    
    BCM d1 : 6.518E-05      BCM d3 : 6.543E-05      BCM d10: 6.589E-05      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3665 at Wed Jan 30 19:10:21 EST 2008
    
    Wien angle : -46.0068
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.948012
    Left Arm arm angle : 20.37
    Right Arm D1 momentum : 0.948014
    Right Arm arm angle : 18.9999
    HALLA:p : 957.178
    HALLA:dpp : -0.0003404
    Tiefenbach Hall A energy : 957.178
    Left Arm Top VDC Current : -2.05078
    Left Arm Bottom VDC Current : 4.49219
    Left Arm Q1 momentum : 0.948046
    Left Arm Q1 power supply : 713.245
    Left Arm Q1 gauss meter : -0.06025
    Left Arm Q2 gauss meter : 0.16154
    Left Arm Q2 power supply current : 408.212
    Left Arm Q2 momentum : 0.948008
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 314.695
    Left Arm D1 momentum : 0.948012
    Left Arm D1 NMR : 0.350996
    Left Arm Q3 gauss meter : -0.19132
    Left Arm Q3 power supply current : 377.488
    Left Arm Q3 momentum : 0.94818
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.947836
    Right Arm Q1 power supply : 712.711
    Right Arm Q1 gauss meter : -0.017966
    Right Arm Q2 power supply current : 408.029
    Right Arm Q2 momentum : 0.948094
    Right Arm Q2 gauss meter : 0.2137
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 324.12
    Right Arm D1 momentum : 0.948014
    Right Arm D1 NMR : 0.351797
    Right Arm Q3 power supply current : 377.13
    Right Arm Q3 momentum : 0.947779
    Right Arm Q3 gauss meter : 0.16864
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 1.00009
    Current on Unser monitor : 13.535
    Current on Upstream bcm : 1.00018
    Current on Downstream bcm : 1
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 1.01313
    Hall C Current : 0
    MBSY1c magnet current (amp) : 39.5773
    MBSY1c Bdl : 239056
    Hall A momentum (Tiefenbach) (HALLA:p) : 957.185
    Hall A momentum orbit correction (dpp) : -0.000333047
    Hall A setup momentum (MMSHLAE) : 960
    Hall A energy (halla_MeV) : 957.185
    Hall C energy (hallc_MeV) : 4592.01
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0.348243
    IPM1H04A.XPOS : -0.117026
    IPM1H04A.YPOS : 1.0071
    IPM1H04B.XPOS : -0.0795071
    IPM1H04B.YPOS : 0.962718
    Left Arm Collimator : 0.871631
    HacL_HPE1313A:0_Ch58 : -0.141602
    HacL_HPE1313A:0_Ch55 : 23.877
    HacL_HPE1313A:0_Ch54 : -0.135254
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.71429
    SLI vert. size mm : 0
    SLI y position : 1.52488
    -----
    Target : Tantalum
    fan frequency loop 1 : 0
    fan frequency loop 3 : 36
    Encoder position : -72743
    Target type : -72743
    temperature loop 1(1) : 109.85
    temperature loop 1(3) : 96.59
    Heat exchange He : 92.8
    temperature loop 3(1) : 19.44
    temperature loop 3(3) : 19.68
    Heat exchange H2 : 19.1
    HPH He loop 1 : 0.0970926
    HPH He loop 2 : 0.00710569
    HPH H2 loop 3 : 0.00634721
    -----