Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 19:38:58 on January 30, 2008

    Entry number 228115

    keyword=End_of_Run_3669
    ****************************
     Run Number: 3669
     End of Run Comment:
    Run_type=Test,target_type=Tantalum,beam_e0=0.956,beam_raster=on,leftarm_p=0.948,leftarm_theta=20.37,leftarm_colli=out,rightarm_p=0.9689,rightarm_theta=19.00,rightarm_colli=out,comment_text=Tantalum, 5uA, momentum still settling
     
    
    PRESCALE FACTORS:ps1=10   ps2=1   ps3=1001   ps4=1   ps5=99999   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 39932        
    TIME     : 0.568 mins  
    
    DEAD TIME:  20.06%      
    
    TRIGGER RATES:   PRES/REAL
    T1:52.5/524.6 Hz   T2:1411.1/1411.1 Hz   T3: 0.0/0.0  Hz   T4: 2.1/2.1  Hz   T5: 0.0/0.0  Hz   T6: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:   1788/17881    T2:  48096/48096    T3:      0/0        T4:     72/72       T5:      0/0        T6:      0/0        T8:      0/34903    
    
    AVERAGE CURRENT
    BCM x1 : 5.1845 uA  BCM x3 : 5.1889 uA  BCM x10: 5.2311 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.0001763      BCM u3 : 0.0001764      BCM u10: 0.0001778      
    
    BCM d1 : 0.0001771      BCM d3 : 0.0001773      BCM d10: 0.0001788      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3669 at Wed Jan 30 19:38:55 EST 2008
    
    Wien angle : -46.0068
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.948013
    Left Arm arm angle : 20.37
    Right Arm D1 momentum : 0.971279
    Right Arm arm angle : 18.9999
    HALLA:p : 957.504
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 957.504
    Left Arm Top VDC Current : 0
    Left Arm Bottom VDC Current : 3.85742
    Left Arm Q1 momentum : 0.948046
    Left Arm Q1 power supply : 713.245
    Left Arm Q1 gauss meter : -0.06025
    Left Arm Q2 gauss meter : 0.16147
    Left Arm Q2 power supply current : 408.213
    Left Arm Q2 momentum : 0.948009
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 314.698
    Left Arm D1 momentum : 0.948013
    Left Arm D1 NMR : 0.350996
    Left Arm Q3 gauss meter : -0.19131
    Left Arm Q3 power supply current : 377.49
    Left Arm Q3 momentum : 0.948182
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.96893
    Right Arm Q1 power supply : 728.626
    Right Arm Q1 gauss meter : -0.018383
    Right Arm Q2 power supply current : 417.04
    Right Arm Q2 momentum : 0.969033
    Right Arm Q2 gauss meter : 0.2185
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 331.626
    Right Arm D1 momentum : 0.971274
    Right Arm D1 NMR : 0.360428
    Right Arm Q3 power supply current : 385.58
    Right Arm Q3 momentum : 0.969015
    Right Arm Q3 gauss meter : 0.17243
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 0.0244665
    Current on Unser monitor : 12.6799
    Current on Upstream bcm : 0.0362491
    Current on Downstream bcm : 0.0126839
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 9.28355
    Hall C Current : 0
    MBSY1c magnet current (amp) : 39.5773
    MBSY1c Bdl : 239056
    Hall A momentum (Tiefenbach) (HALLA:p) : 957.504
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 960
    Hall A energy (halla_MeV) : 957.504
    Hall C energy (hallc_MeV) : 4592.01
    Delta(E)/E width (MV_AI_DXWID) : 0
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Left Arm Collimator : 0.87168
    HacL_HPE1313A:0_Ch58 : -0.140625
    HacL_HPE1313A:0_Ch55 : 23.8281
    HacL_HPE1313A:0_Ch54 : -0.134766
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.71429
    SLI vert. size mm : 0
    SLI y position : 1.52488
    -----
    Target : Tantalum
    fan frequency loop 1 : 0
    fan frequency loop 3 : 36
    Encoder position : -72742
    Target type : -72742
    temperature loop 1(1) : 109.96
    temperature loop 1(3) : 96.58
    Heat exchange He : 92.8
    temperature loop 3(1) : 19.43
    temperature loop 3(3) : 19.67
    Heat exchange H2 : 19.1
    HPH He loop 1 : 0.0540192
    HPH He loop 2 : 0.00710569
    HPH H2 loop 3 : 0.011068
    -----