Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 19:55:41 on January 30, 2008

    Entry number 228119

    keyword=End_of_Run_6022
    ****************************
     Run Number: 6022
     End of Run Comment:
    Run_type=Production,target_type=Iron 50 degs  Right,beam_e0=0.9574,beam_raster=on,beam_halfwaveplate=out,leftarm_p=0.948,leftarm_theta=20.37,leftarm_colli=out,rightarm_p=0.948,rightarm_theta=19,rightarm_colli=out,comment_text=Ta target Jan-30-2008-100V.txt
     
    
    PRESCALE FACTORS:ps1=9999   ps2=9999   ps3=1   ps4=5   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 654752       
    TIME     : 41.798 mins  
    
    DEAD TIME:  53.11%      
    
    TRIGGER RATES:   PRES/REAL
    T1: 0.0/397.4 Hz   T2: 0.0/0.0  Hz   T3:551.5/551.5 Hz   T4: 5.3/26.3 Hz   T5: 0.0/0.0  Hz   T6: 0.0/261.1 Hz   T7: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   T9: 0.0/0.0  Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:     99/996647   T2:      0/0        T3:1383060/1383060  T4:  13212/66064    T5:      0/0        T6:      9/654752   T7:      0/0        T8:     39/2568085  T9:      0/0        
    
    AVERAGE CURRENT
    BCM x1 : 4.3203 uA  BCM x3 : 4.3256 uA  BCM x10: 4.3494 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.01082        BCM u3 : 0.01082        BCM u10: 0.01089        
    
    BCM d1 : 0.01085        BCM d3 : 0.01088        BCM d10: 0.01092        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 6022 at Wed Jan 30 19:55:37 EST 2008
    
    Wien angle : -46.0068
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.948013
    Left Arm arm angle : 20.37
    Right Arm D1 momentum : 0.968662
    Right Arm arm angle : 18.9999
    HALLA:p : 957.403
    HALLA:dpp : -0.000105131
    Tiefenbach Hall A energy : 957.403
    Left Arm Top VDC Current : 2.63672
    Left Arm Bottom VDC Current : 2.09961
    Left Arm Q1 momentum : 0.948117
    Left Arm Q1 power supply : 713.298
    Left Arm Q1 gauss meter : -0.06025
    Left Arm Q2 gauss meter : 0.1615
    Left Arm Q2 power supply current : 408.213
    Left Arm Q2 momentum : 0.948011
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 314.693
    Left Arm D1 momentum : 0.948013
    Left Arm D1 NMR : 0.350996
    Left Arm Q3 gauss meter : -0.19133
    Left Arm Q3 power supply current : 377.491
    Left Arm Q3 momentum : 0.948186
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.969001
    Right Arm Q1 power supply : 728.679
    Right Arm Q1 gauss meter : -0.018364
    Right Arm Q2 power supply current : 417.04
    Right Arm Q2 momentum : 0.969032
    Right Arm Q2 gauss meter : 0.2185
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 331.412
    Right Arm D1 momentum : 0.968661
    Right Arm D1 NMR : 0.359459
    Right Arm Q3 power supply current : 385.581
    Right Arm Q3 momentum : 0.969018
    Right Arm Q3 gauss meter : 0.17243
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 5.10908
    Current on Unser monitor : 16.3142
    Current on Upstream bcm : 5.11707
    Current on Downstream bcm : 5.1011
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 5.09582
    Hall C Current : 0
    MBSY1c magnet current (amp) : 39.5773
    MBSY1c Bdl : 239056
    Hall A momentum (Tiefenbach) (HALLA:p) : 957.403
    Hall A momentum orbit correction (dpp) : -0.000105131
    Hall A setup momentum (MMSHLAE) : 960
    Hall A energy (halla_MeV) : 957.403
    Hall C energy (hallc_MeV) : 4592.01
    Delta(E)/E width (MV_AI_DXWID) : 1.03457
    IPM1C12.XPOS : -0.00593466
    IPM1H04A.XPOS : 0.0219313
    IPM1H04A.YPOS : 0.923171
    IPM1H04B.XPOS : 0.00412601
    IPM1H04B.YPOS : 1.00286
    Left Arm Collimator : 0.871729
    HacL_HPE1313A:0_Ch58 : -0.140625
    HacL_HPE1313A:0_Ch55 : 23.9258
    HacL_HPE1313A:0_Ch54 : -0.134766
    -----
    SLI data valid? : Yes
    SLI horiz size mm : 0.0592234
    SLI Energy spread *10^5 : 1.48059
    SLI x position : 1.49068
    SLI vert. size mm : 0.404905
    SLI y position : 1.52488
    -----
    Target : Tantalum
    Vacuum Pressure : 3.95375e-07
    fan frequency loop 1 : 0
    fan frequency loop 3 : 36
    Encoder position : -72742
    Target type : -72742
    temperature loop 1(1) : 110.02
    temperature loop 1(3) : 96.61
    Heat exchange He : 92.8
    temperature loop 3(1) : 19.42
    temperature loop 3(3) : 19.66
    Heat exchange H2 : 19.1
    HPH He loop 1 : 0.0813417
    HPH H2 loop 3 : 0.00293052