    Log entry time 20:59:39 on January 30, 2008

    Entry number 228130

    keyword=End_of_Run_6024
    ****************************
     Run Number: 6024
     End of Run Comment:
    Run_type=Production,target_type=Iron 50 degs  Right,beam_e0=0.9574,beam_raster=on,beam_halfwaveplate=out,leftarm_p=0.900,leftarm_theta=20.37,leftarm_colli=out,rightarm_p=0.948,rightarm_theta=19,rightarm_colli=out,comment_text=Ta target Jan-30-2008-100V_c.txt
     
    
    PRESCALE FACTORS:ps1=9999   ps2=9999   ps3=1   ps4=5   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 375286       
    TIME     : 23.565 mins  
    
    DEAD TIME:  80.77%      
    
    TRIGGER RATES:   PRES/REAL
    T1: 0.1/573.9 Hz   T2: 0.0/0.0  Hz   T3:1372.5/1372.5 Hz   T4: 7.9/39.4 Hz   T5: 0.0/0.0  Hz   T6: 0.0/265.4 Hz   T7: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   T9: 0.0/0.0  Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:     81/811434   T2:      0/0        T3:1940648/1940648  T4:  11147/55736    T5:      0/0        T6:      5/375286   T7:      0/0        T8:     22/1447850  T9:      0/0        
    
    AVERAGE CURRENT
    BCM x1 : 5.1579 uA  BCM x3 : 5.1628 uA  BCM x10: 5.1906 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.007282       BCM u3 : 0.007282       BCM u10: 0.00733        
    
    BCM d1 : 0.007304       BCM d3 : 0.007318       BCM d10: 0.007348       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 6024 at Wed Jan 30 20:59:37 EST 2008
    
    Wien angle : -46.0068
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.899979
    Left Arm arm angle : 20.37
    Right Arm D1 momentum : 0.968877
    Right Arm arm angle : 18.9999
    HALLA:p : 957.4
    HALLA:dpp : -0.000109024
    Tiefenbach Hall A energy : 957.4
    Left Arm Top VDC Current : 3.90625
    Left Arm Bottom VDC Current : 4.00391
    Left Arm Q1 momentum : 0.899916
    Left Arm Q1 power supply : 677.035
    Left Arm Q1 gauss meter : -0.05719
    Left Arm Q2 gauss meter : 0.1534
    Left Arm Q2 power supply current : 387.523
    Left Arm Q2 momentum : 0.89996
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 298.463
    Left Arm D1 momentum : 0.899979
    Left Arm D1 NMR : 0.333225
    Left Arm Q3 gauss meter : -0.18159
    Left Arm Q3 power supply current : 358.3
    Left Arm Q3 momentum : 0.899982
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.969001
    Right Arm Q1 power supply : 728.626
    Right Arm Q1 gauss meter : -0.018366
    Right Arm Q2 power supply current : 417.041
    Right Arm Q2 momentum : 0.969034
    Right Arm Q2 gauss meter : 0.2184
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 331.319
    Right Arm D1 momentum : 0.968877
    Right Arm D1 NMR : 0.359539
    Right Arm Q3 power supply current : 385.584
    Right Arm Q3 momentum : 0.969025
    Right Arm Q3 gauss meter : 0.17242
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 5.13336
    Current on Unser monitor : 17.1181
    Current on Upstream bcm : 5.13652
    Current on Downstream bcm : 5.13294
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 5.13233
    Hall C Current : 0
    MBSY1c magnet current (amp) : 39.5773
    MBSY1c Bdl : 239056
    Hall A momentum (Tiefenbach) (HALLA:p) : 957.407
    Hall A momentum orbit correction (dpp) : -0.000101747
    Hall A setup momentum (MMSHLAE) : 960
    Hall A energy (halla_MeV) : 957.407
    Hall C energy (hallc_MeV) : 4592.01
    Delta(E)/E width (MV_AI_DXWID) : 1.0026
    IPM1C12.XPOS : 0.00124136
    IPM1H04A.XPOS : 0.0145345
    IPM1H04A.YPOS : 0.940404
    IPM1H04B.XPOS : -0.0036965
    IPM1H04B.YPOS : 1.01084
    Left Arm Collimator : 0.871631
    HacL_HPE1313A:0_Ch58 : -0.141602
    HacL_HPE1313A:0_Ch55 : 23.877
    HacL_HPE1313A:0_Ch54 : -0.135254
    -----
    SLI data valid? : Yes
    SLI horiz size mm : 0.34037
    SLI Energy spread *10^5 : 8.50925
    SLI x position : 1.47578
    SLI vert. size mm : 0.0592234
    SLI y position : 1.52488
    -----
    Target : Tantalum
    Vacuum Pressure : 3.95375e-07
    fan frequency loop 1 : 0
    fan frequency loop 3 : 36
    Encoder position : -72742
    Target type : -72742
    temperature loop 1(1) : 110.14
    temperature loop 1(3) : 96.76
    Heat exchange He : 92.8
    temperature loop 3(1) : 19.37
    temperature loop 3(3) : 19.61
    Heat exchange H2 : 19
    HPH He loop 1 : 0.0669839
    HPH H2 loop 3 : 0.00634721