NEXT
User name a-onl
Log entry time 21:52:03 on January 30, 2008
Entry number 228141
keyword=End_of_Run_3673
****************************
Run Number: 3673
End of Run Comment:
Run_type=Test,target_type=Tantalum,beam_e0=0.956,beam_raster=on,leftarm_p=0.948,leftarm_theta=20.37,leftarm_colli=out,rightarm_p=0.96793,rightarm_theta=19.00,rightarm_colli=out,comment_text=Tantalum, 50uA, momentum still settling only stack detector threshold at 30 mV
PRESCALE FACTORS:ps1=10000 ps2=16000000 ps3=1001 ps4=1 ps5=99999 ps6=65535 ps7=65535 ps8=65535
EVENTS : 70064
TIME : 15.618 mins
DEAD TIME: 3.31%
TRIGGER RATES: PRES/REAL
T1: 0.5/4700.2 Hz T2: 0.0/533840.8 Hz T3: 0.0/0.0 Hz T4:76.8/76.8 Hz T5: 0.0/0.0 Hz T6: 0.0/0.0 Hz T8: 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1: 440/4404507 T2: 31/500253167 T3: 0/0 T4: 71980/71980 T5: 0/0 T6: 0/0 T8: 14/959573
AVERAGE CURRENT
BCM x1 : 42.1125uA BCM x3 : 42.1000uA BCM x10: 36.5747uA
APPROXIMATE BCM CHARGES (C)
BCM u1 : 0.03941 BCM u3 : 0.03941 BCM u10: 0.03419
BCM d1 : 0.03951 BCM d3 : 0.03949 BCM d10: 0.03436
****************************
End-of-run EPICS data for Run Number 3673 at Wed Jan 30 21:52:00 EST 2008
Wien angle : -46.0068
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.899984
Left Arm arm angle : 20.37
Right Arm D1 momentum : 0.967879
Right Arm arm angle : 18.9999
HALLA:p : 957.634
HALLA:dpp : 0.000136065
Tiefenbach Hall A energy : 957.634
Left Arm Top VDC Current : 3.4668
Left Arm Bottom VDC Current : -2.19727
Left Arm Q1 momentum : 0.899845
Left Arm Q1 power supply : 676.982
Left Arm Q1 gauss meter : -0.05718
Left Arm Q2 gauss meter : 0.15334
Left Arm Q2 power supply current : 387.523
Left Arm Q2 momentum : 0.89996
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 298.484
Left Arm D1 momentum : 0.899984
Left Arm D1 NMR : 0.333227
Left Arm Q3 gauss meter : -0.18152
Left Arm Q3 power supply current : 358.108
Left Arm Q3 momentum : 0.899541
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 0.967865
Right Arm Q1 power supply : 727.825
Right Arm Q1 gauss meter : -0.018364
Right Arm Q2 power supply current : 416.562
Right Arm Q2 momentum : 0.967921
Right Arm Q2 gauss meter : 0.2182
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 331.021
Right Arm D1 momentum : 0.967879
Right Arm D1 NMR : 0.359169
Right Arm Q3 power supply current : 385.153
Right Arm Q3 momentum : 0.967944
Right Arm Q3 gauss meter : 0.17223
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 50.2364
Current on Unser monitor : 61.4008
Current on Upstream bcm : 50.2675
Current on Downstream bcm : 50.2052
Upstream Cavity Coefficient : 43.377
Downstream Cavity Coefficient : 42.913
Current on IBC0L02 (source) : 49.5446
Hall C Current : 0
MBSY1c magnet current (amp) : 39.5773
MBSY1c Bdl : 239056
Hall A momentum (Tiefenbach) (HALLA:p) : 957.634
Hall A momentum orbit correction (dpp) : 0.000135754
Hall A setup momentum (MMSHLAE) : 960
Hall A energy (halla_MeV) : 957.634
Hall C energy (hallc_MeV) : 4592.01
Delta(E)/E width (MV_AI_DXWID) : 1.0295
IPM1C12.XPOS : -0.346869
IPM1H04A.XPOS : -0.0193177
IPM1H04A.YPOS : 0.996845
IPM1H04B.XPOS : -0.0135784
IPM1H04B.YPOS : 0.996169
Left Arm Collimator : 0.87168
HacL_HPE1313A:0_Ch58 : -0.141602
HacL_HPE1313A:0_Ch55 : 23.8281
HacL_HPE1313A:0_Ch54 : -0.135254
SLI data valid? : Yes
SLI horiz size mm : 0.174842
SLI Energy spread *10^5 : 4.37105
SLI x position : 1.49068
SLI vert. size mm : 0.194088
SLI y position : 1.51737
-----
Target : Tantalum
fan frequency loop 1 : 0
fan frequency loop 3 : 36
Encoder position : -72742
Target type : -72742
temperature loop 1(1) : 110.21
temperature loop 1(3) : 96.56
Heat exchange He : 92.8
temperature loop 3(1) : 19.37
temperature loop 3(3) : 19.6
Heat exchange H2 : 19
HPH He loop 1 : 0.0970926
HPH He loop 2 : 0.00356948
HPH H2 loop 3 : 0.00634721
-----