    Entry number 228144

    keyword=End_of_Run_3674
    ****************************
     Run Number: 3674
     End of Run Comment:
    Run_type=Test,target_type=Tantalum,beam_e0=0.956,beam_raster=on,leftarm_p=0.948,leftarm_theta=20.37,leftarm_colli=out,rightarm_p=0.96793,rightarm_theta=19.00,rightarm_colli=out,comment_text=Tantalum, 50uA, momentum still settling only stack detector threshold at 20 mV
     
    
    PRESCALE FACTORS:ps1=10000   ps2=16000000   ps3=1001   ps4=1   ps5=99999   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 25642        
    TIME     : 4.986 mins  
    
    DEAD TIME:   1.70%      
    
    TRIGGER RATES:   PRES/REAL
    T1: 0.5/4940.6 Hz   T2: 0.2/3474898.3 Hz   T3: 0.0/0.0  Hz   T4:86.5/86.5 Hz   T5: 0.0/0.0  Hz   T6: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:    147/1477955  T2:     64/1039496806  T3:      0/0        T4:  25871/25871    T5:      0/0        T6:      0/0        T8:      4/306324   
    
    AVERAGE CURRENT
    BCM x1 : 44.4176uA  BCM x3 : 44.4040uA  BCM x10: 38.6148uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.01327        BCM u3 : 0.01327        BCM u10: 0.01153        
    
    BCM d1 : 0.0133         BCM d3 : 0.0133         BCM d10: 0.01158        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3674 at Wed Jan 30 21:59:30 EST 2008
    
    Wien angle : -46.0068
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.899984
    Left Arm arm angle : 20.37
    Right Arm D1 momentum : 0.967966
    Right Arm arm angle : 18.9999
    HALLA:p : 957.406
    HALLA:dpp : -0.000102662
    Tiefenbach Hall A energy : 957.406
    Left Arm Top VDC Current : 2.68555
    Left Arm Bottom VDC Current : -0.146484
    Left Arm Q1 momentum : 0.899916
    Left Arm Q1 power supply : 677.035
    Left Arm Q1 gauss meter : -0.05719
    Left Arm Q2 gauss meter : 0.15338
    Left Arm Q2 power supply current : 387.524
    Left Arm Q2 momentum : 0.899963
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 298.479
    Left Arm D1 momentum : 0.899984
    Left Arm D1 NMR : 0.333227
    Left Arm Q3 gauss meter : -0.18129
    Left Arm Q3 power supply current : 357.685
    Left Arm Q3 momentum : 0.898442
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.967936
    Right Arm Q1 power supply : 727.825
    Right Arm Q1 gauss meter : -0.018346
    Right Arm Q2 power supply current : 416.563
    Right Arm Q2 momentum : 0.967924
    Right Arm Q2 gauss meter : 0.2182
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 331.044
    Right Arm D1 momentum : 0.967966
    Right Arm D1 NMR : 0.359201
    Right Arm Q3 power supply current : 385.154
    Right Arm Q3 momentum : 0.967946
    Right Arm Q3 gauss meter : 0.17223
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 49.6395
    Current on Unser monitor : 60.8288
    Current on Upstream bcm : 49.4869
    Current on Downstream bcm : 49.7922
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 48.9888
    Hall C Current : 0
    MBSY1c magnet current (amp) : 39.5773
    MBSY1c Bdl : 239056
    Hall A momentum (Tiefenbach) (HALLA:p) : 957.408
    Hall A momentum orbit correction (dpp) : -0.000100653
    Hall A setup momentum (MMSHLAE) : 960
    Hall A energy (halla_MeV) : 957.408
    Hall C energy (hallc_MeV) : 4592.01
    Delta(E)/E width (MV_AI_DXWID) : 1.03458
    IPM1C12.XPOS : 0.00421572
    IPM1H04A.XPOS : 0.0295468
    IPM1H04A.YPOS : 0.950601
    IPM1H04B.XPOS : 0.0175209
    IPM1H04B.YPOS : 1.01955
    Left Arm Collimator : 0.87168
    HacL_HPE1313A:0_Ch58 : -0.141602
    HacL_HPE1313A:0_Ch55 : 23.8281
    HacL_HPE1313A:0_Ch54 : -0.135254
    SLI data valid? : Yes
    SLI horiz size mm : 0.184721
    SLI Energy spread *10^5 : 4.61803
    SLI x position : 1.50559
    SLI vert. size mm : 0.147208
    SLI y position : 1.53239
    -----
    Target : Tantalum
    fan frequency loop 1 : 0
    fan frequency loop 3 : 36
    Encoder position : -72742
    Target type : -72742
    temperature loop 1(1) : 110.23
    temperature loop 1(3) : 96.68
    Heat exchange He : 92.8
    temperature loop 3(1) : 19.37
    temperature loop 3(3) : 19.61
    Heat exchange H2 : 19
    HPH He loop 1 : 0.0669839
    HPH He loop 2 : 0.00710569
    HPH H2 loop 3 : 0.00634721
    -----