NEXT
User name a-onl
Log entry time 22:02:51 on January 30, 2008
Entry number 228147
keyword=End_of_Run_3675
****************************
Run Number: 3675
End of Run Comment:
Run_type=Test,target_type=Tantalum,beam_e0=0.956,beam_raster=on,leftarm_p=0.948,leftarm_theta=20.37,leftarm_colli=out,rightarm_p=0.96793,rightarm_theta=19.00,rightarm_colli=out,comment_text=Tantalum, 50uA, threshold at 50 mV mostly S0 trigger
PRESCALE FACTORS:ps1=10000 ps2=10 ps3=1001 ps4=1 ps5=99999 ps6=65535 ps7=65535 ps8=65535
EVENTS : 60988
TIME : 1.745 mins
DEAD TIME: 2.44%
TRIGGER RATES: PRES/REAL
T1: 0.6/5554.5 Hz T2:520.3/5203.3 Hz T3: 0.0/0.0 Hz T4:76.3/76.3 Hz T5: 0.0/0.0 Hz T6: 0.0/0.0 Hz T8: 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1: 58/581411 T2: 54465/544652 T3: 0/0 T4: 7990/7990 T5: 0/0 T6: 0/0 T8: 1/107186
AVERAGE CURRENT
BCM x1 : 49.8867uA BCM x3 : 49.8704uA BCM x10: 43.1437uA
APPROXIMATE BCM CHARGES (C)
BCM u1 : 0.005215 BCM u3 : 0.005214 BCM u10: 0.004502
BCM d1 : 0.005229 BCM d3 : 0.005226 BCM d10: 0.00453
****************************
End-of-run EPICS data for Run Number 3675 at Wed Jan 30 22:02:48 EST 2008
Wien angle : -46.0068
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.899985
Left Arm arm angle : 20.37
Right Arm D1 momentum : 0.967957
Right Arm arm angle : 18.9999
HALLA:p : 957.408
HALLA:dpp : -0.000100349
Tiefenbach Hall A energy : 957.408
Left Arm Top VDC Current : 2.24609
Left Arm Bottom VDC Current : -0.976562
Left Arm Q1 momentum : 0.899916
Left Arm Q1 power supply : 677.035
Left Arm Q1 gauss meter : -0.05719
Left Arm Q2 gauss meter : 0.15337
Left Arm Q2 power supply current : 387.524
Left Arm Q2 momentum : 0.899962
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 298.48
Left Arm D1 momentum : 0.899985
Left Arm D1 NMR : 0.333227
Left Arm Q3 gauss meter : -0.18187
Left Arm Q3 power supply current : 358.881
Left Arm Q3 momentum : 0.901444
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 0.967936
Right Arm Q1 power supply : 727.825
Right Arm Q1 gauss meter : -0.018338
Right Arm Q2 power supply current : 416.564
Right Arm Q2 momentum : 0.967927
Right Arm Q2 gauss meter : 0.2182
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 330.991
Right Arm D1 momentum : 0.967957
Right Arm D1 NMR : 0.359197
Right Arm Q3 power supply current : 385.155
Right Arm Q3 momentum : 0.967948
Right Arm Q3 gauss meter : 0.17223
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 49.9467
Current on Unser monitor : 60.7791
Current on Upstream bcm : 49.9136
Current on Downstream bcm : 50.0365
Upstream Cavity Coefficient : 43.377
Downstream Cavity Coefficient : 42.913
Current on IBC0L02 (source) : 49.4933
Hall C Current : 0
MBSY1c magnet current (amp) : 39.5773
MBSY1c Bdl : 239056
Hall A momentum (Tiefenbach) (HALLA:p) : 957.405
Hall A momentum orbit correction (dpp) : -0.000103715
Hall A setup momentum (MMSHLAE) : 960
Hall A energy (halla_MeV) : 957.405
Hall C energy (hallc_MeV) : 4592.01
Delta(E)/E width (MV_AI_DXWID) : 1.06159
IPM1C12.XPOS : -0.002882
IPM1H04A.XPOS : 0.0332071
IPM1H04A.YPOS : 0.895643
IPM1H04B.XPOS : 0.00345182
IPM1H04B.YPOS : 0.938458
Left Arm Collimator : 0.87168
HacL_HPE1313A:0_Ch58 : -0.141113
HacL_HPE1313A:0_Ch55 : 23.7793
HacL_HPE1313A:0_Ch54 : -0.134277
SLI data valid? : Yes
SLI horiz size mm : 0.177258
SLI Energy spread *10^5 : 4.43145
SLI x position : 1.50559
SLI vert. size mm : 0.158221
SLI y position : 1.53239
-----
Target : Tantalum
fan frequency loop 1 : 0
fan frequency loop 3 : 36
Encoder position : -72742
Target type : -72742
temperature loop 1(1) : 110.24
temperature loop 1(3) : 96.7
Heat exchange He : 92.8
temperature loop 3(1) : 19.37
temperature loop 3(3) : 19.62
Heat exchange H2 : 19.1
HPH He loop 1 : 0.0813417
HPH He loop 2 : 0.00710569
HPH H2 loop 3 : 0.011068
-----