Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 22:23:33 on January 30, 2008

    Entry number 228150

    keyword=End_of_Run_6026
    ****************************
     Run Number: 6026
     End of Run Comment:
    Run_type=Production,target_type=Iron 50 degs  Right,beam_e0=0.9574,beam_raster=on,beam_halfwaveplate=out,leftarm_p=0.900,leftarm_theta=20.37,leftarm_colli=out,rightarm_p=0.948,rightarm_theta=19,rightarm_colli=out,comment_text=Ta target Jan-30-2008-100V_d.txt
     
    
    PRESCALE FACTORS:ps1=9999   ps2=9999   ps3=3   ps4=5   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 677473       
    TIME     : 38.617 mins  
    
    DEAD TIME:  92.80%      
    
    TRIGGER RATES:   PRES/REAL
    T1: 0.5/5146.6 Hz   T2: 0.0/0.0  Hz   T3:3995.3/11985.9 Hz   T4:64.0/320.2 Hz   T5: 0.0/0.0  Hz   T6: 0.0/292.4 Hz   T7: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   T9: 0.0/0.0  Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:   1192/11924772  T2:      0/0        T3:9257096/27771290  T4: 148370/741852   T5:      0/0        T6:     10/677473   T7:      0/0        T8:     36/2372608  T9:      0/0        
    
    AVERAGE CURRENT
    BCM x1 : 46.2642uA  BCM x3 : 46.4433uA  BCM x10: 0.5496 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.1071         BCM u3 : 0.107          BCM u10: 0.09243        
    
    BCM d1 : 0.1073         BCM d3 : 0.1082         BCM d10: -0.08988       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 6026 at Wed Jan 30 22:23:30 EST 2008
    
    Wien angle : -46.0068
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.899984
    Left Arm arm angle : 20.37
    Right Arm D1 momentum : 0.967949
    Right Arm arm angle : 18.9999
    HALLA:p : 957.407
    HALLA:dpp : -0.000101431
    Tiefenbach Hall A energy : 957.407
    Left Arm Top VDC Current : 0.0488281
    Left Arm Bottom VDC Current : -0.732422
    Left Arm Q1 momentum : 0.899916
    Left Arm Q1 power supply : 677.035
    Left Arm Q1 gauss meter : -0.05718
    Left Arm Q2 gauss meter : 0.15335
    Left Arm Q2 power supply current : 387.524
    Left Arm Q2 momentum : 0.899963
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 298.485
    Left Arm D1 momentum : 0.899984
    Left Arm D1 NMR : 0.333227
    Left Arm Q3 gauss meter : -0.18161
    Left Arm Q3 power supply current : 358.309
    Left Arm Q3 momentum : 0.900005
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.967936
    Right Arm Q1 power supply : 727.825
    Right Arm Q1 gauss meter : -0.018347
    Right Arm Q2 power supply current : 416.564
    Right Arm Q2 momentum : 0.967927
    Right Arm Q2 gauss meter : 0.2182
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 330.967
    Right Arm D1 momentum : 0.967949
    Right Arm D1 NMR : 0.359194
    Right Arm Q3 power supply current : 385.192
    Right Arm Q3 momentum : 0.968041
    Right Arm Q3 gauss meter : 0.17225
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 50.1155
    Current on Unser monitor : 61.2474
    Current on Upstream bcm : 50.225
    Current on Downstream bcm : 50.0059
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 49.6531
    Hall C Current : 0
    MBSY1c magnet current (amp) : 39.5773
    MBSY1c Bdl : 239056
    Hall A momentum (Tiefenbach) (HALLA:p) : 957.407
    Hall A momentum orbit correction (dpp) : -0.000101431
    Hall A setup momentum (MMSHLAE) : 960
    Hall A energy (halla_MeV) : 957.407
    Hall C energy (hallc_MeV) : 4592.01
    Delta(E)/E width (MV_AI_DXWID) : 1.06381
    IPM1C12.XPOS : -0.00550139
    IPM1H04A.XPOS : 0.00792789
    IPM1H04A.YPOS : 0.932947
    IPM1H04B.XPOS : -0.0118241
    IPM1H04B.YPOS : 0.998886
    Left Arm Collimator : 0.87168
    HacL_HPE1313A:0_Ch58 : -0.14209
    HacL_HPE1313A:0_Ch55 : 23.7793
    HacL_HPE1313A:0_Ch54 : -0.135254
    -----
    SLI data valid? : Yes
    SLI horiz size mm : 0.142687
    SLI Energy spread *10^5 : 3.56716
    SLI x position : 1.50559
    SLI vert. size mm : 0.167717
    SLI y position : 1.53239
    -----
    Target : Tantalum
    Vacuum Pressure : 4.08364e-07
    fan frequency loop 1 : 0
    fan frequency loop 3 : 36
    Encoder position : -72742
    Target type : -72742
    temperature loop 1(1) : 110.26
    temperature loop 1(3) : 96.71
    Heat exchange He : 92.8
    temperature loop 3(1) : 19.37
    temperature loop 3(3) : 19.6
    Heat exchange H2 : 19
    HPH He loop 1 : 0.0669839