Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 23:00:56 on January 30, 2008

    Entry number 228163

    keyword=End_of_Run_6027
    ****************************
     Run Number: 6027
     End of Run Comment:
    Run_type=Production,target_type=Iron 50 degs  Right,beam_e0=0.9574,beam_raster=on,beam_halfwaveplate=out,leftarm_p=0.900,leftarm_theta=20.37,leftarm_colli=out,rightarm_p=0.948,rightarm_theta=19,rightarm_colli=out,comment_text=Ta target Jan-30-2008-100V_e.txt
     
    
    PRESCALE FACTORS:ps1=9999   ps2=9999   ps3=3   ps4=5   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 619802       
    TIME     : 35.328 mins  
    
    DEAD TIME:  92.57%      
    
    TRIGGER RATES:   PRES/REAL
    T1: 0.5/4944.0 Hz   T2: 0.0/0.0  Hz   T3:3873.8/11621.3 Hz   T4:62.2/310.8 Hz   T5: 0.0/0.0  Hz   T6: 0.0/292.4 Hz   T7: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   T9: 0.0/0.0  Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:   1048/10479862  T2:      0/0        T3:8211219/24633657  T4: 131780/658900   T5:      0/0        T6:      9/619802   T7:      0/0        T8:     33/2170574  T9:      0/0        
    
    AVERAGE CURRENT
    BCM x1 : 44.8591uA  BCM x3 : 45.0354uA  BCM x10: 38.8576uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.09501        BCM u3 : 0.09496        BCM u10: 0.08235        
    
    BCM d1 : 0.09517        BCM d3 : 0.09597        BCM d10: 0.08238        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 6027 at Wed Jan 30 23:00:53 EST 2008
    
    Wien angle : -46.0068
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.899983
    Left Arm arm angle : 20.37
    Right Arm D1 momentum : 0.967944
    Right Arm arm angle : 18.9999
    HALLA:p : 957.408
    HALLA:dpp : -0.000100144
    Tiefenbach Hall A energy : 957.408
    Left Arm Top VDC Current : 2.63672
    Left Arm Bottom VDC Current : -1.5625
    Left Arm Q1 momentum : 0.899845
    Left Arm Q1 power supply : 677.035
    Left Arm Q1 gauss meter : -0.05718
    Left Arm Q2 gauss meter : 0.15337
    Left Arm Q2 power supply current : 387.523
    Left Arm Q2 momentum : 0.899961
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 298.482
    Left Arm D1 momentum : 0.899983
    Left Arm D1 NMR : 0.333226
    Left Arm Q3 gauss meter : -0.18207
    Left Arm Q3 power supply current : 359.302
    Left Arm Q3 momentum : 0.902499
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.967936
    Right Arm Q1 power supply : 727.825
    Right Arm Q1 gauss meter : -0.018347
    Right Arm Q2 power supply current : 416.563
    Right Arm Q2 momentum : 0.967923
    Right Arm Q2 gauss meter : 0.2182
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 330.967
    Right Arm D1 momentum : 0.967943
    Right Arm D1 NMR : 0.359192
    Right Arm Q3 power supply current : 424.165
    Right Arm Q3 momentum : 1.06598
    Right Arm Q3 gauss meter : 0.18955
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 49.8912
    Current on Unser monitor : 61.424
    Current on Upstream bcm : 49.8788
    Current on Downstream bcm : 49.9037
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 49.4136
    Hall C Current : 0
    MBSY1c magnet current (amp) : 39.5773
    MBSY1c Bdl : 239056
    Hall A momentum (Tiefenbach) (HALLA:p) : 957.406
    Hall A momentum orbit correction (dpp) : -0.000102701
    Hall A setup momentum (MMSHLAE) : 960
    Hall A energy (halla_MeV) : 957.406
    Hall C energy (hallc_MeV) : 4592.01
    Delta(E)/E width (MV_AI_DXWID) : 1.06053
    IPM1C12.XPOS : -0.00440684
    IPM1H04A.XPOS : 0.0212699
    IPM1H04A.YPOS : 0.923953
    IPM1H04B.XPOS : -0.000401974
    IPM1H04B.YPOS : 0.993489
    Left Arm Collimator : 0.871777
    HacL_HPE1313A:0_Ch58 : -0.141602
    HacL_HPE1313A:0_Ch55 : 23.8281
    HacL_HPE1313A:0_Ch54 : -0.134766
    -----
    SLI data valid? : Yes
    SLI horiz size mm : 0.122251
    SLI Energy spread *10^5 : 3.05628
    SLI x position : 1.50559
    SLI vert. size mm : 0.174043
    SLI y position : 1.53239
    -----
    Target : Tantalum
    Vacuum Pressure : 4.05647e-07
    fan frequency loop 1 : 0
    fan frequency loop 3 : 36
    Encoder position : -72742
    Target type : -72742
    temperature loop 1(1) : 110.29
    temperature loop 1(3) : 96.64
    Heat exchange He : 92.8
    temperature loop 3(1) : 19.36
    temperature loop 3(3) : 19.6
    Heat exchange H2 : 19
    HPH He loop 1 : 0.0813417
    HPH H2 loop 3 : 0.011068