NEXT
User name a-onl
Log entry time 23:16:53 on January 30, 2008
Entry number 228166
keyword=End_of_Run_3679
****************************
Run Number: 3679
End of Run Comment:
Run_type=Test,target_type=Tantalum,beam_e0=0.956,beam_raster=on,leftarm_p=0.948,leftarm_theta=20.37,leftarm_colli=out,rightarm_p=0.96793,rightarm_theta=19.00,rightarm_colli=out,comment_text=Tantalum, 50uA, threshold at 50 mV stack trigger only Q3 at +10%
PRESCALE FACTORS:ps1=10000 ps2=10000000 ps3=1001 ps4=1 ps5=99999 ps6=65535 ps7=65535 ps8=65535
EVENTS : 90446
TIME : 20.397 mins
DEAD TIME: 17.25%
TRIGGER RATES: PRES/REAL
T1: 0.5/5138.7 Hz T2: 0.0/4799.4 Hz T3: 0.0/0.0 Hz T4:88.8/88.8 Hz T5: 0.0/0.0 Hz T6: 0.0/0.0 Hz T8: 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1: 628/6288917 T2: 0/5873676 T3: 0/0 T4: 108658/108658 T5: 0/0 T6: 0/0 T8: 19/1253213
AVERAGE CURRENT
BCM x1 : 48.6031uA BCM x3 : 48.5873uA BCM x10: 42.0040uA
APPROXIMATE BCM CHARGES (C)
BCM u1 : 0.05939 BCM u3 : 0.05938 BCM u10: 0.05132
BCM d1 : 0.05958 BCM d3 : 0.05955 BCM d10: 0.05149
****************************
End-of-run EPICS data for Run Number 3679 at Wed Jan 30 23:16:50 EST 2008
Wien angle : -46.0068
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.899984
Left Arm arm angle : 20.37
Right Arm D1 momentum : 0.967943
Right Arm arm angle : 18.9999
HALLA:p : 957.407
HALLA:dpp : -0.000100738
Tiefenbach Hall A energy : 957.408
Left Arm Top VDC Current : 1.95312
Left Arm Bottom VDC Current : 2.97852
Left Arm Q1 momentum : 0.899845
Left Arm Q1 power supply : 676.982
Left Arm Q1 gauss meter : -0.05718
Left Arm Q2 gauss meter : 0.15333
Left Arm Q2 power supply current : 387.525
Left Arm Q2 momentum : 0.899965
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 298.483
Left Arm D1 momentum : 0.899984
Left Arm D1 NMR : 0.333226
Left Arm Q3 gauss meter : -0.18154
Left Arm Q3 power supply current : 358.158
Left Arm Q3 momentum : 0.899635
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 0.967865
Right Arm Q1 power supply : 727.771
Right Arm Q1 gauss meter : -0.018337
Right Arm Q2 power supply current : 416.564
Right Arm Q2 momentum : 0.967927
Right Arm Q2 gauss meter : 0.2182
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 330.967
Right Arm D1 momentum : 0.967943
Right Arm D1 NMR : 0.359192
Right Arm Q3 power supply current : 424.167
Right Arm Q3 momentum : 1.06599
Right Arm Q3 gauss meter : 0.18955
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 49.7379
Current on Unser monitor : 59.4623
Current on Upstream bcm : 49.6841
Current on Downstream bcm : 49.7916
Upstream Cavity Coefficient : 43.377
Downstream Cavity Coefficient : 42.913
Current on IBC0L02 (source) : 49.1866
Hall C Current : 0
MBSY1c magnet current (amp) : 39.5773
MBSY1c Bdl : 239056
Hall A momentum (Tiefenbach) (HALLA:p) : 957.408
Hall A momentum orbit correction (dpp) : -0.000100384
Hall A setup momentum (MMSHLAE) : 960
Hall A energy (halla_MeV) : 957.408
Hall C energy (hallc_MeV) : 4592.01
Delta(E)/E width (MV_AI_DXWID) : 1.04908
IPM1C12.XPOS : -0.00540435
IPM1H04A.XPOS : 0.0288869
IPM1H04A.YPOS : 0.957005
IPM1H04B.XPOS : -0.00453162
IPM1H04B.YPOS : 1.01867
Left Arm Collimator : 0.87168
HacL_HPE1313A:0_Ch58 : -0.141602
HacL_HPE1313A:0_Ch55 : 23.8281
HacL_HPE1313A:0_Ch54 : -0.135254
SLI data valid? : Yes
SLI horiz size mm : 0.142882
SLI Energy spread *10^5 : 3.57205
SLI x position : 1.49068
SLI vert. size mm : 0.164114
SLI y position : 1.53239
-----
Target : Tantalum
fan frequency loop 1 : 0
fan frequency loop 3 : 36
Encoder position : -72742
Target type : -72742
temperature loop 1(1) : 110.3
temperature loop 1(3) : 96.82
Heat exchange He : 92.9
temperature loop 3(1) : 19.37
temperature loop 3(3) : 19.61
Heat exchange H2 : 19
HPH He loop 1 : 0.0970926
HPH He loop 2 : 0.00356948
HPH H2 loop 3 : 0.00634721
-----