     Run Number: 3682
     End of Run Comment:
    Run_type=Test,target_type=Tantalum,beam_e0=0.956,beam_raster=on,leftarm_p=0.948,leftarm_theta=20.37,leftarm_colli=out,rightarm_p=0.96793,rightarm_theta=19.00,rightarm_colli=out,comment_text=Tantalum, 50uA, threshold at 50 mV stack trigger only Q3 at +10% S0 and stack triggers HV S0 at 1500 V
     
    
    PRESCALE FACTORS:ps1=10000   ps2=10   ps3=1001   ps4=1   ps5=99999   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 224428       
    TIME     : 3.538 mins  
    
    DEAD TIME:   3.03%      
    
    TRIGGER RATES:   PRES/REAL
    T1: 0.5/5313.6 Hz   T2:998.1/9981.1 Hz   T3: 0.0/0.0  Hz   T4:91.8/91.8 Hz   T5: 0.0/0.0  Hz   T6: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:    112/1127876  T2: 211862/2118624  T3:      0/0        T4:  19477/19477    T5:      0/0        T6:      0/0        T8:      3/217358   
    
    AVERAGE CURRENT
    BCM x1 : 50.2051uA  BCM x3 : 50.1885uA  BCM x10: 43.2448uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.01064        BCM u3 : 0.01064        BCM u10: 0.009155       
    
    BCM d1 : 0.01067        BCM d3 : 0.01066        BCM d10: 0.009203       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3682 at Wed Jan 30 23:56:48 EST 2008
    
    Wien angle : -46.0068
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.899983
    Left Arm arm angle : 20.37
    Right Arm D1 momentum : 0.967944
    Right Arm arm angle : 18.9999
    HALLA:p : 957.404
    HALLA:dpp : -0.000103927
    Tiefenbach Hall A energy : 957.405
    Left Arm Top VDC Current : -2.34375
    Left Arm Bottom VDC Current : -2.34375
    Left Arm Q1 momentum : 0.899916
    Left Arm Q1 power supply : 676.982
    Left Arm Q1 gauss meter : -0.05718
    Left Arm Q2 gauss meter : 0.15335
    Left Arm Q2 power supply current : 387.524
    Left Arm Q2 momentum : 0.899963
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 298.484
    Left Arm D1 momentum : 0.899983
    Left Arm D1 NMR : 0.333226
    Left Arm Q3 gauss meter : -0.18164
    Left Arm Q3 power supply current : 358.369
    Left Arm Q3 momentum : 0.900158
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.967865
    Right Arm Q1 power supply : 727.771
    Right Arm Q1 gauss meter : -0.018354
    Right Arm Q2 power supply current : 416.564
    Right Arm Q2 momentum : 0.967926
    Right Arm Q2 gauss meter : 0.2182
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 330.967
    Right Arm D1 momentum : 0.967945
    Right Arm D1 NMR : 0.359193
    Right Arm Q3 power supply current : 424.17
    Right Arm Q3 momentum : 1.066
    Right Arm Q3 gauss meter : 0.18956
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 50.012
    Current on Unser monitor : 60.2163
    Current on Upstream bcm : 50.0058
    Current on Downstream bcm : 50.0182
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 49.5732
    Hall C Current : 0
    MBSY1c magnet current (amp) : 39.5773
    MBSY1c Bdl : 239056
    Hall A momentum (Tiefenbach) (HALLA:p) : 957.407
    Hall A momentum orbit correction (dpp) : -0.00010171
    Hall A setup momentum (MMSHLAE) : 960
    Hall A energy (halla_MeV) : 957.407
    Hall C energy (hallc_MeV) : 4592.01
    Delta(E)/E width (MV_AI_DXWID) : 1.05711
    IPM1C12.XPOS : -0.00540704
    IPM1H04A.XPOS : 0.0140669
    IPM1H04A.YPOS : 0.946474
    IPM1H04B.XPOS : -0.00663394
    IPM1H04B.YPOS : 0.992016
    Left Arm Collimator : 0.871631
    HacL_HPE1313A:0_Ch58 : -0.14209
    HacL_HPE1313A:0_Ch55 : 23.8281
    HacL_HPE1313A:0_Ch54 : -0.134277
    SLI data valid? : Yes
    SLI horiz size mm : 0.152557
    SLI Energy spread *10^5 : 3.81393
    SLI x position : 1.50559
    SLI vert. size mm : 0.162226
    SLI y position : 1.53239
    -----
    Target : Tantalum
    fan frequency loop 1 : 0
    fan frequency loop 3 : 36.5
    Encoder position : -72742
    Target type : -72742
    temperature loop 1(1) : 110.33
    temperature loop 1(3) : 96.67
    Heat exchange He : 92.9
    temperature loop 3(1) : 19.37
    temperature loop 3(3) : 19.61
    Heat exchange H2 : 19.1
    HPH He loop 1 : 0.0669839
    HPH He loop 2 : 0.00710569
    HPH H2 loop 3 : 0.00634721
    -----