Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 00:48:34 on January 31, 2008

    Entry number 228195

    keyword=End_of_Run_3686
    ****************************
     Run Number: 3686
     End of Run Comment:
    Run_type=Test,target_type=Tantalum,beam_e0=0.956,beam_raster=on,leftarm_p=0.948,leftarm_theta=20.37,leftarm_colli=out,rightarm_p=0.96793,rightarm_theta=19.00,rightarm_colli=out,comment_text=Tantalum, 50uA, threshold at 200 mV S0 trigger only Q3 at +10% S0 and stack triggers HV S0 at 1500 V
     
    
    PRESCALE FACTORS:ps1=10000   ps2=1   ps3=1001   ps4=999999   ps5=99999   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 706495       
    TIME     : 40.276 mins  
    
    DEAD TIME:   5.20%      
    
    TRIGGER RATES:   PRES/REAL
    T1: 0.4/3682.1 Hz   T2:308.0/308.0 Hz   T3: 0.0/0.0  Hz   T4: 0.0/5.0  Hz   T5: 0.0/0.0  Hz   T6: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:    889/8898035  T2: 744369/744369   T3:      0/0        T4:      0/12182    T5:      0/0        T6:      0/0        T8:     37/2474562  
    
    AVERAGE CURRENT
    BCM x1 : 34.8058uA  BCM x3 : 34.7942uA  BCM x10: 30.1519uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.08401        BCM u3 : 0.084          BCM u10: 0.07258        
    
    BCM d1 : 0.08421        BCM d3 : 0.08416        BCM d10: 0.07315        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3686 at Thu Jan 31 00:48:30 EST 2008
    
    Wien angle : -46.0068
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.899983
    Left Arm arm angle : 20.37
    Right Arm D1 momentum : 0.967945
    Right Arm arm angle : 18.9999
    HALLA:p : 957.504
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 957.504
    Left Arm Top VDC Current : 0.683594
    Left Arm Bottom VDC Current : -0.439453
    Left Arm Q1 momentum : 0.899845
    Left Arm Q1 power supply : 676.982
    Left Arm Q1 gauss meter : -0.05719
    Left Arm Q2 gauss meter : 0.15337
    Left Arm Q2 power supply current : 387.524
    Left Arm Q2 momentum : 0.899962
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 298.483
    Left Arm D1 momentum : 0.899983
    Left Arm D1 NMR : 0.333226
    Left Arm Q3 gauss meter : -0.18151
    Left Arm Q3 power supply current : 358.23
    Left Arm Q3 momentum : 0.899777
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.967936
    Right Arm Q1 power supply : 727.771
    Right Arm Q1 gauss meter : -0.01835
    Right Arm Q2 power supply current : 416.563
    Right Arm Q2 momentum : 0.967924
    Right Arm Q2 gauss meter : 0.2182
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 330.967
    Right Arm D1 momentum : 0.967945
    Right Arm D1 NMR : 0.359193
    Right Arm Q3 power supply current : 424.177
    Right Arm Q3 momentum : 1.06601
    Right Arm Q3 gauss meter : 0.18956
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 0.0240661
    Current on Unser monitor : 11.4241
    Current on Upstream bcm : 0.0356159
    Current on Downstream bcm : 0.0125164
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 0.0123542
    Hall C Current : 0
    MBSY1c magnet current (amp) : 0.0377198
    MBSY1c Bdl : 239056
    Hall A momentum (Tiefenbach) (HALLA:p) : 957.504
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 960
    Hall A energy (halla_MeV) : 957.504
    Hall C energy (hallc_MeV) : 4592.01
    Delta(E)/E width (MV_AI_DXWID) : 1.07608
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Left Arm Collimator : 0.87168
    HacL_HPE1313A:0_Ch58 : -0.142578
    HacL_HPE1313A:0_Ch55 : 23.7793
    HacL_HPE1313A:0_Ch54 : -0.135254
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 2.22857
    SLI vert. size mm : 0
    SLI y position : 1.40469
    -----
    Target : Tantalum
    fan frequency loop 1 : 0
    fan frequency loop 3 : 36
    Encoder position : -72742
    Target type : -72742
    temperature loop 1(1) : 110.36
    temperature loop 1(3) : 96.77
    Heat exchange He : 92.9
    temperature loop 3(1) : 19.33
    temperature loop 3(3) : 19.57
    Heat exchange H2 : 19
    HPH He loop 1 : 0.0813417
    HPH He loop 2 : 0.00710569
    HPH H2 loop 3 : 0.011068
    -----