    Log entry time 01:46:01 on January 31, 2008

    Entry number 228207

    keyword=End_of_Run_3690
    ****************************
     Run Number: 3690
     End of Run Comment:
    Run_type=Cosmics,target_type=Tantalum,beam_e0=0.956,beam_raster=on,leftarm_p=0.948,leftarm_theta=20.37,leftarm_colli=out,rightarm_p=0.96793,rightarm_theta=19.00,rightarm_colli=out,comment_text=Tantalum, 50uA, threshold at 20 mV S0 trigger and T4 only Q3 at +10% S0 and stack triggers HV S0 at 1500 V
     
    
    PRESCALE FACTORS:ps1=10000   ps2=10000000   ps3=1001   ps4=1   ps5=99999   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 405          
    TIME     : 3.666 mins  
    
    DEAD TIME:   0.56%      
    
    TRIGGER RATES:   PRES/REAL
    T1: 0.0/10.3 Hz   T2: 0.3/3484129.6 Hz   T3: 0.0/0.0  Hz   T4: 1.5/1.5  Hz   T5: 0.0/0.0  Hz   T6: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:      0/2266     T2:     76/766352007  T3:      0/0        T4:    327/327      T5:      0/0        T6:      0/0        T8:      3/225234   
    
    AVERAGE CURRENT
    BCM x1 : 0.0012 uA  BCM x3 : 0.0002 uA  BCM x10: -0.0004uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 3.605E-07      BCM u3 : 2.617E-07      BCM u10: 2.127E-07      
    
    BCM d1 : 1.862E-07      BCM d3 : -1.883E-07     BCM d10: -3.976E-07     
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3690 at Thu Jan 31 01:45:56 EST 2008
    
    Wien angle : -46.0068
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.899982
    Left Arm arm angle : 20.37
    Right Arm D1 momentum : 0.967944
    Right Arm arm angle : 18.9999
    HALLA:p : 957.504
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 957.504
    Left Arm Top VDC Current : 2.7832
    Left Arm Bottom VDC Current : 1.70898
    Left Arm Q1 momentum : 0.899916
    Left Arm Q1 power supply : 677.035
    Left Arm Q1 gauss meter : -0.05719
    Left Arm Q2 gauss meter : 0.15339
    Left Arm Q2 power supply current : 387.524
    Left Arm Q2 momentum : 0.899963
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 298.483
    Left Arm D1 momentum : 0.899981
    Left Arm D1 NMR : 0.333226
    Left Arm Q3 gauss meter : -0.18157
    Left Arm Q3 power supply current : 358.242
    Left Arm Q3 momentum : 0.899838
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.967936
    Right Arm Q1 power supply : 727.825
    Right Arm Q1 gauss meter : -0.018351
    Right Arm Q2 power supply current : 416.562
    Right Arm Q2 momentum : 0.967922
    Right Arm Q2 gauss meter : 0.2183
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 330.967
    Right Arm D1 momentum : 0.967944
    Right Arm D1 NMR : 0.359193
    Right Arm Q3 power supply current : 424.166
    Right Arm Q3 momentum : 1.06599
    Right Arm Q3 gauss meter : 0.18956
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 0.0240919
    Current on Unser monitor : 12.6829
    Current on Upstream bcm : 0.0356381
    Current on Downstream bcm : 0.0125456
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 0.007433
    Hall C Current : 0
    MBSY1c magnet current (amp) : 39.5773
    MBSY1c Bdl : 239056
    Hall A momentum (Tiefenbach) (HALLA:p) : 957.504
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 960
    Hall A energy (halla_MeV) : 957.504
    Hall C energy (hallc_MeV) : 4592.01
    Delta(E)/E width (MV_AI_DXWID) : 0.276575
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Left Arm Collimator : 0.87168
    HacL_HPE1313A:0_Ch58 : -0.142578
    HacL_HPE1313A:0_Ch55 : 23.7305
    HacL_HPE1313A:0_Ch54 : -0.135254
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 2.01988
    SLI vert. size mm : 0
    SLI y position : 1.40469
    -----
    Target : Tantalum
    fan frequency loop 1 : 0
    fan frequency loop 3 : 36
    Encoder position : -72742
    Target type : -72742
    temperature loop 1(1) : 110.39
    temperature loop 1(3) : 96.56
    Heat exchange He : 92.9
    temperature loop 3(1) : 19.3
    temperature loop 3(3) : 19.54
    Heat exchange H2 : 19
    HPH He loop 1 : 0.0813417
    HPH He loop 2 : 0.00710569
    HPH H2 loop 3 : 0.00634721
    -----