NEXT
User name a-onl
Log entry time 02:03:54 on January 31, 2008
Entry number 228214
keyword=End_of_Run_3695
****************************
Run Number: 3695
End of Run Comment:
Run_type=Cosmics,target_type=Tantalum,beam_e0=0.956,beam_raster=on,leftarm_p=0.948,leftarm_theta=20.37,leftarm_colli=out,rightarm_p=0.96793,rightarm_theta=19.00,rightarm_colli=out,comment_text=Tantalum, 50uA, threshold at 100 mV S0 trigger and T4 only Q3 at +10% S0 and stack triggers HV S0 at 1500 V
PRESCALE FACTORS:ps1=10000 ps2=100 ps3=1001 ps4=1 ps5=99999 ps6=65535 ps7=65535 ps8=65535
EVENTS : 15118
TIME : 2.863 mins
DEAD TIME: 1.15%
TRIGGER RATES: PRES/REAL
T1: 0.5/5215.7 Hz T2:61.1/6106.1 Hz T3: 0.0/0.0 Hz T4:27.4/27.4 Hz T5: 0.0/0.0 Hz T6: 0.0/0.0 Hz T8: 0.0/1024.0 Hz
TRIGGER TOTALS: PRES/REAL
T1: 89/895868 T2: 10487/1048795 T3: 0/0 T4: 4714/4714 T5: 0/0 T6: 0/0 T8: 2/175885
AVERAGE CURRENT
BCM x1 : 49.8756uA BCM x3 : 49.8591uA BCM x10: 43.0740uA
APPROXIMATE BCM CHARGES (C)
BCM u1 : 0.008553 BCM u3 : 0.008552 BCM u10: 0.007386
BCM d1 : 0.00858 BCM d3 : 0.008576 BCM d10: 0.007411
****************************
End-of-run EPICS data for Run Number 3695 at Thu Jan 31 02:03:50 EST 2008
Wien angle : -46.0068
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.899982
Left Arm arm angle : 20.37
Right Arm D1 momentum : 0.967946
Right Arm arm angle : 18.9999
HALLA:p : 957.41
HALLA:dpp : -9.76718e-05
Tiefenbach Hall A energy : 957.411
Left Arm Top VDC Current : -1.41602
Left Arm Bottom VDC Current : 0.78125
Left Arm Q1 momentum : 0.899916
Left Arm Q1 power supply : 676.982
Left Arm Q1 gauss meter : -0.05718
Left Arm Q2 gauss meter : 0.15337
Left Arm Q2 power supply current : 387.524
Left Arm Q2 momentum : 0.899963
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 298.484
Left Arm D1 momentum : 0.899982
Left Arm D1 NMR : 0.333226
Left Arm Q3 gauss meter : -0.18159
Left Arm Q3 power supply current : 358.286
Left Arm Q3 momentum : 0.899947
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 0.967936
Right Arm Q1 power supply : 727.825
Right Arm Q1 gauss meter : -0.018364
Right Arm Q2 power supply current : 416.564
Right Arm Q2 momentum : 0.967927
Right Arm Q2 gauss meter : 0.2182
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 330.967
Right Arm D1 momentum : 0.967945
Right Arm D1 NMR : 0.359193
Right Arm Q3 power supply current : 424.165
Right Arm Q3 momentum : 1.06598
Right Arm Q3 gauss meter : 0.18956
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 49.7925
Current on Unser monitor : 61.4191
Current on Upstream bcm : 49.7046
Current on Downstream bcm : 49.8803
Upstream Cavity Coefficient : 43.377
Downstream Cavity Coefficient : 42.913
Current on IBC0L02 (source) : 49.2716
Hall C Current : 0
MBSY1c magnet current (amp) : 39.5773
MBSY1c Bdl : 239056
Hall A momentum (Tiefenbach) (HALLA:p) : 957.409
Hall A momentum orbit correction (dpp) : -9.91389e-05
Hall A setup momentum (MMSHLAE) : 960
Hall A energy (halla_MeV) : 957.409
Hall C energy (hallc_MeV) : 4592.01
Delta(E)/E width (MV_AI_DXWID) : 1.10165
IPM1C12.XPOS : -0.00412193
IPM1H04A.XPOS : 0.0240429
IPM1H04A.YPOS : 0.947623
IPM1H04B.XPOS : 0.00697035
IPM1H04B.YPOS : 1.00197
Left Arm Collimator : 0.871631
HacL_HPE1313A:0_Ch58 : -0.14209
HacL_HPE1313A:0_Ch55 : 23.7305
HacL_HPE1313A:0_Ch54 : -0.135742
SLI data valid? : Yes
SLI horiz size mm : 0.17733
SLI Energy spread *10^5 : 4.43325
SLI x position : 1.50559
SLI vert. size mm : 0.174798
SLI y position : 1.53239
-----
Target : Tantalum
fan frequency loop 1 : 0
fan frequency loop 3 : 36.5
Encoder position : -72742
Target type : -72742
temperature loop 1(1) : 110.38
temperature loop 1(3) : 96.69
Heat exchange He : 92.9
temperature loop 3(1) : 19.32
temperature loop 3(3) : 19.56
Heat exchange H2 : 19
HPH He loop 1 : 0.0813417
HPH He loop 2 : 0.00356948
HPH H2 loop 3 : 0.011068
-----