Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 02:23:50 on January 31, 2008

    Entry number 228221

    keyword=End_of_Run_3700
    ****************************
     Run Number: 3700
     End of Run Comment:
    Run_type=Cosmics,target_type=Tantalum,beam_e0=0.956,beam_raster=on,leftarm_p=0.948,leftarm_theta=20.37,leftarm_colli=out,rightarm_p=0.96793,rightarm_theta=19.00,rightarm_colli=out,comment_text=Tantalum, 50uA, threshold at 100 mV S0 trigger and T4 only Q3 at +10% S0 and stack triggers HV S0 at 1500 V and delay increaded by 16 ns compared to usual
     
    
    PRESCALE FACTORS:ps1=10000   ps2=100   ps3=1001   ps4=1   ps5=99999   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 15718        
    TIME     : 2.936 mins  
    
    DEAD TIME:   1.08%      
    
    TRIGGER RATES:   PRES/REAL
    T1: 0.5/5237.8 Hz   T2:61.7/6168.0 Hz   T3: 0.0/0.0  Hz   T4:28.0/28.0 Hz   T5: 0.0/0.0  Hz   T6: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:     92/922698   T2:  10865/1086570  T3:      0/0        T4:   4929/4929     T5:      0/0        T6:      0/0        T8:      2/180389   
    
    AVERAGE CURRENT
    BCM x1 : 49.9125uA  BCM x3 : 49.8960uA  BCM x10: 43.1370uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.00878        BCM u3 : 0.008779       BCM u10: 0.007577       
    
    BCM d1 : 0.008805       BCM d3 : 0.008801       BCM d10: 0.007621       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3700 at Thu Jan 31 02:23:46 EST 2008
    
    Wien angle : -46.0068
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.899981
    Left Arm arm angle : 20.37
    Right Arm D1 momentum : 0.967946
    Right Arm arm angle : 18.9999
    HALLA:p : 957.41
    HALLA:dpp : -9.79689e-05
    Tiefenbach Hall A energy : 957.41
    Left Arm Top VDC Current : 1.70898
    Left Arm Bottom VDC Current : 0.439453
    Left Arm Q1 momentum : 0.899916
    Left Arm Q1 power supply : 677.035
    Left Arm Q1 gauss meter : -0.05719
    Left Arm Q2 gauss meter : 0.15335
    Left Arm Q2 power supply current : 387.525
    Left Arm Q2 momentum : 0.899966
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 298.483
    Left Arm D1 momentum : 0.899981
    Left Arm D1 NMR : 0.333226
    Left Arm Q3 gauss meter : -0.18162
    Left Arm Q3 power supply current : 358.348
    Left Arm Q3 momentum : 0.900102
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.967936
    Right Arm Q1 power supply : 727.825
    Right Arm Q1 gauss meter : -0.018339
    Right Arm Q2 power supply current : 416.564
    Right Arm Q2 momentum : 0.967927
    Right Arm Q2 gauss meter : 0.2182
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 330.967
    Right Arm D1 momentum : 0.967946
    Right Arm D1 NMR : 0.359193
    Right Arm Q3 power supply current : 424.166
    Right Arm Q3 momentum : 1.06599
    Right Arm Q3 gauss meter : 0.18956
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 49.8782
    Current on Unser monitor : 61.9388
    Current on Upstream bcm : 50.0039
    Current on Downstream bcm : 49.7525
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 49.3852
    Hall C Current : 0
    MBSY1c magnet current (amp) : 39.5773
    MBSY1c Bdl : 239056
    Hall A momentum (Tiefenbach) (HALLA:p) : 957.407
    Hall A momentum orbit correction (dpp) : -0.000101746
    Hall A setup momentum (MMSHLAE) : 960
    Hall A energy (halla_MeV) : 957.407
    Hall C energy (hallc_MeV) : 4592.01
    Delta(E)/E width (MV_AI_DXWID) : 1.14469
    IPM1C12.XPOS : -0.00270218
    IPM1H04A.XPOS : -0.00825012
    IPM1H04A.YPOS : 0.955023
    IPM1H04B.XPOS : -0.0103428
    IPM1H04B.YPOS : 1.01979
    Left Arm Collimator : 0.87168
    HacL_HPE1313A:0_Ch58 : -0.14209
    HacL_HPE1313A:0_Ch55 : 23.7793
    HacL_HPE1313A:0_Ch54 : -0.134766
    SLI data valid? : Yes
    SLI horiz size mm : 0.157026
    SLI Energy spread *10^5 : 3.92566
    SLI x position : 1.50559
    SLI vert. size mm : 0.170858
    SLI y position : 1.53239
    -----
    Target : Tantalum
    fan frequency loop 1 : 0
    fan frequency loop 3 : 36.5
    Encoder position : -72742
    Target type : -72742
    temperature loop 1(1) : 110.39
    temperature loop 1(3) : 96.75
    Heat exchange He : 92.9
    temperature loop 3(1) : 19.33
    temperature loop 3(3) : 19.57
    Heat exchange H2 : 19
    HPH He loop 1 : 0.0540192
    HPH He loop 2 : 0.0118473
    HPH H2 loop 3 : 0.00634721
    -----