NEXT
User name adev
Log entry time 02:42:01 on January 31, 2008
Entry number 228226
keyword=End_of_Run_6032
****************************
Run Number: 6032
End of Run Comment:
Run_type=Production,target_type=Iron 50 degs Right,beam_e0=0.9574,beam_raster=on,beam_halfwaveplate=out,leftarm_p=0.900,leftarm_theta=20.37,leftarm_colli=out,rightarm_p=0.948,rightarm_theta=19,rightarm_colli=out,comment_text=Ta target Jan-30-2008-100V_m.txt, ended due to controlled access
PRESCALE FACTORS:ps1=9999 ps2=9999 ps3=4 ps4=15 ps5=65535 ps6=65535 ps7=65535 ps8=65535
EVENTS : 184755
TIME : 11.483 mins
DEAD TIME: 91.67%
TRIGGER RATES: PRES/REAL
T1: 0.5/5188.6 Hz T2: 0.0/0.0 Hz T3:3197.4/12789.7 Hz T4:22.7/341.0 Hz T5: 0.0/0.0 Hz T6: 0.0/268.1 Hz T7: 0.0/0.0 Hz T8: 0.0/1024.0 Hz T9: 0.0/0.0 Hz
TRIGGER TOTALS: PRES/REAL
T1: 357/3574984 T2: 0/0 T3:2203048/8812193 T4: 15663/234946 T5: 0/0 T6: 2/184755 T7: 0/0 T8: 10/705543 T9: 0/0
AVERAGE CURRENT
BCM x1 : 49.4780uA BCM x3 : 49.6857uA BCM x10: 42.7148uA
APPROXIMATE BCM CHARGES (C)
BCM u1 : 0.03407 BCM u3 : 0.03405 BCM u10: 0.02937
BCM d1 : 0.03412 BCM d3 : 0.03442 BCM d10: 0.0295
****************************
End-of-run EPICS data for Run Number 6032 at Thu Jan 31 02:41:59 EST 2008
Wien angle : -46.0068
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.899983
Left Arm arm angle : 20.37
Right Arm D1 momentum : 0.967946
Right Arm arm angle : 18.9999
HALLA:p : 957.504
HALLA:dpp : 0
Tiefenbach Hall A energy : 957.504
Left Arm Top VDC Current : 5.17578
Left Arm Bottom VDC Current : -1.36719
Left Arm Q1 momentum : 0.899916
Left Arm Q1 power supply : 677.035
Left Arm Q1 gauss meter : -0.05718
Left Arm Q2 gauss meter : 0.15337
Left Arm Q2 power supply current : 387.527
Left Arm Q2 momentum : 0.899969
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 298.486
Left Arm D1 momentum : 0.899982
Left Arm D1 NMR : 0.333226
Left Arm Q3 gauss meter : -0.18162
Left Arm Q3 power supply current : 358.346
Left Arm Q3 momentum : 0.900099
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 0.967936
Right Arm Q1 power supply : 727.771
Right Arm Q1 gauss meter : -0.018359
Right Arm Q2 power supply current : 416.564
Right Arm Q2 momentum : 0.967927
Right Arm Q2 gauss meter : 0.2182
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 330.967
Right Arm D1 momentum : 0.967946
Right Arm D1 NMR : 0.359193
Right Arm Q3 power supply current : 424.167
Right Arm Q3 momentum : 1.06599
Right Arm Q3 gauss meter : 0.18956
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 0.024415
Current on Unser monitor : 12.6307
Current on Upstream bcm : 0.0362322
Current on Downstream bcm : 0.0125977
Upstream Cavity Coefficient : 43.377
Downstream Cavity Coefficient : 42.913
Current on IBC0L02 (source) : 0.0132271
Hall C Current : 0
MBSY1c magnet current (amp) : 0.0377198
MBSY1c Bdl : 239056
Hall A momentum (Tiefenbach) (HALLA:p) : 957.504
Hall A momentum orbit correction (dpp) : 0
Hall A setup momentum (MMSHLAE) : 960
Hall A energy (halla_MeV) : 957.504
Hall C energy (hallc_MeV) : 4592.01
Delta(E)/E width (MV_AI_DXWID) : 1.14391
IPM1C12.XPOS : 0
IPM1H04A.XPOS : 0
IPM1H04A.YPOS : 0
IPM1H04B.XPOS : 0
IPM1H04B.YPOS : 0
Left Arm Collimator : 0.871631
HacL_HPE1313A:0_Ch58 : -0.143066
HacL_HPE1313A:0_Ch55 : 23.7793
HacL_HPE1313A:0_Ch54 : -0.134766
-----
SLI data valid? : No
SLI horiz size mm : 0
SLI Energy spread *10^5 : 0
SLI x position : 1.50559
SLI vert. size mm : 0
SLI y position : 1.53239
-----
Target : Tantalum
Vacuum Pressure : 3.73368e-07
fan frequency loop 1 : 0
fan frequency loop 3 : 35.5
Encoder position : -72742
Target type : -72742
temperature loop 1(1) : 110.39
temperature loop 1(3) : 96.65
Heat exchange He : 92.9
temperature loop 3(1) : 19.32
temperature loop 3(3) : 19.56
Heat exchange H2 : 19
HPH He loop 1 : 0.0669839
HPH H2 loop 3 : 0.0170928