Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 04:10:25 on January 31, 2008

    Entry number 228240

    keyword=End_of_Run_6034
    ****************************
     Run Number: 6034
     End of Run Comment:
    Run_type=Production,target_type=Iron 50 degs  Right,beam_e0=0.9574,beam_raster=on,beam_halfwaveplate=out,leftarm_p=0.900,leftarm_theta=20.37,leftarm_colli=out,rightarm_p=0.948,rightarm_theta=19,rightarm_colli=out,comment_text=Ta target Jan-30-2008-100V_n.txt, end due to reducing current
     
    
    PRESCALE FACTORS:ps1=9999   ps2=9999   ps3=3   ps4=15   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 22209        
    TIME     : 1.110 mins  
    
    DEAD TIME:  90.76%      
    
    TRIGGER RATES:   PRES/REAL
    T1: 0.4/4357.1 Hz   T2: 0.0/0.0  Hz   T3:3588.5/10765.5 Hz   T4:18.9/283.6 Hz   T5: 0.0/0.0  Hz   T6: 0.0/333.4 Hz   T7: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   T9: 0.0/0.0  Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:     29/290222   T2:      0/0        T3: 239024/717072   T4:   1259/18893    T5:      0/0        T6:      0/22209    T7:      0/0        T8:      1/68207    T9:      0/0        
    
    AVERAGE CURRENT
    BCM x1 : 41.6678uA  BCM x3 : 41.8102uA  BCM x10: 36.7277uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.002774       BCM u3 : 0.002772       BCM u10: 0.002445       
    
    BCM d1 : 0.002777       BCM d3 : 0.002797       BCM d10: 0.002448       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 6034 at Thu Jan 31 04:10:21 EST 2008
    
    Wien angle : -46.0068
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.89998
    Left Arm arm angle : 20.37
    Right Arm D1 momentum : 0.967945
    Right Arm arm angle : 18.9999
    HALLA:p : 957.437
    HALLA:dpp : -7.00678e-05
    Tiefenbach Hall A energy : 957.437
    Left Arm Top VDC Current : 5.07812
    Left Arm Bottom VDC Current : 0.732422
    Left Arm Q1 momentum : 0.899916
    Left Arm Q1 power supply : 677.035
    Left Arm Q1 gauss meter : -0.05719
    Left Arm Q2 gauss meter : 0.15338
    Left Arm Q2 power supply current : 387.526
    Left Arm Q2 momentum : 0.899967
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 298.49
    Left Arm D1 momentum : 0.89998
    Left Arm D1 NMR : 0.333225
    Left Arm Q3 gauss meter : -0.18169
    Left Arm Q3 power supply current : 358.836
    Left Arm Q3 momentum : 0.901329
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.967936
    Right Arm Q1 power supply : 727.825
    Right Arm Q1 gauss meter : -0.018348
    Right Arm Q2 power supply current : 416.565
    Right Arm Q2 momentum : 0.967928
    Right Arm Q2 gauss meter : 0.2182
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 330.967
    Right Arm D1 momentum : 0.967944
    Right Arm D1 NMR : 0.359193
    Right Arm Q3 power supply current : 424.167
    Right Arm Q3 momentum : 1.06599
    Right Arm Q3 gauss meter : 0.18956
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 8.15123
    Current on Unser monitor : 20.7081
    Current on Upstream bcm : 8.14915
    Current on Downstream bcm : 8.15332
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 8.11268
    Hall C Current : 0
    MBSY1c magnet current (amp) : 39.5773
    MBSY1c Bdl : 239056
    Hall A momentum (Tiefenbach) (HALLA:p) : 957.441
    Hall A momentum orbit correction (dpp) : -6.85934e-05
    Hall A setup momentum (MMSHLAE) : 960
    Hall A energy (halla_MeV) : 957.438
    Hall C energy (hallc_MeV) : 4592.01
    Delta(E)/E width (MV_AI_DXWID) : 0.915838
    IPM1C12.XPOS : -0.102747
    IPM1H04A.XPOS : -0.0593536
    IPM1H04A.YPOS : 0.909564
    IPM1H04B.XPOS : -0.0245611
    IPM1H04B.YPOS : 0.958793
    Left Arm Collimator : 0.871631
    HacL_HPE1313A:0_Ch58 : -0.142578
    HacL_HPE1313A:0_Ch55 : 23.7305
    HacL_HPE1313A:0_Ch54 : -0.134766
    -----
    SLI data valid? : Yes
    SLI horiz size mm : 0.238991
    SLI Energy spread *10^5 : 5.97476
    SLI x position : 1.50559
    SLI vert. size mm : 0.161569
    SLI y position : 1.53239
    -----
    Target : Tantalum
    Vacuum Pressure : 4.0636e-07
    fan frequency loop 1 : 0
    fan frequency loop 3 : 36
    Encoder position : -72742
    Target type : -72742
    temperature loop 1(1) : 110.41
    temperature loop 1(3) : 96.74
    Heat exchange He : 92.9
    temperature loop 3(1) : 19.37
    temperature loop 3(3) : 19.61
    Heat exchange H2 : 19
    HPH He loop 1 : 0.0669839
    HPH H2 loop 3 : 0.00634721