Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 04:52:12 on January 31, 2008

    Entry number 228248

    keyword=End_of_Run_6036
    ****************************
     Run Number: 6036
     End of Run Comment:
    Run_type=Production,target_type=Iron 50 degs  Right,beam_e0=0.9574,beam_raster=on,beam_halfwaveplate=out,leftarm_p=0.900,leftarm_theta=20.37,leftarm_colli=out,rightarm_p=0.948,rightarm_theta=19,rightarm_colli=out,comment_text=Ta target Jan-30-2008-100V_n.txt, controlled access
     
    
    PRESCALE FACTORS:ps1=9999   ps2=9999   ps3=1   ps4=2   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 91307        
    TIME     : 5.919 mins  
    
    DEAD TIME:  86.85%      
    
    TRIGGER RATES:   PRES/REAL
    T1: 0.1/783.5 Hz   T2: 0.0/0.0  Hz   T3:1929.5/1929.5 Hz   T4:25.9/51.8 Hz   T5: 0.0/0.0  Hz   T6: 0.0/257.1 Hz   T7: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   T9: 0.0/0.0  Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:     27/278253   T2:      0/0        T3: 685249/685249   T4:   9201/18403    T5:      0/0        T6:      1/91307    T7:      0/0        T8:      5/363659   T9:      0/0        
    
    AVERAGE CURRENT
    BCM x1 : 7.4028 uA  BCM x3 : 7.4106 uA  BCM x10: 7.4487 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.002627       BCM u3 : 0.002627       BCM u10: 0.002644       
    
    BCM d1 : 0.002631       BCM d3 : 0.002637       BCM d10: 0.002647       
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 6036 at Thu Jan 31 04:52:09 EST 2008
    
    Wien angle : -46.0068
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.899979
    Left Arm arm angle : 20.37
    Right Arm D1 momentum : 0.967945
    Right Arm arm angle : 18.9999
    HALLA:p : 957.504
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 957.504
    Left Arm Top VDC Current : -1.95312
    Left Arm Bottom VDC Current : 3.27148
    Left Arm Q1 momentum : 0.899845
    Left Arm Q1 power supply : 677.035
    Left Arm Q1 gauss meter : -0.05718
    Left Arm Q2 gauss meter : 0.15333
    Left Arm Q2 power supply current : 387.525
    Left Arm Q2 momentum : 0.899965
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 298.481
    Left Arm D1 momentum : 0.899979
    Left Arm D1 NMR : 0.333225
    Left Arm Q3 gauss meter : -0.1816
    Left Arm Q3 power supply current : 358.309
    Left Arm Q3 momentum : 0.900005
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.967936
    Right Arm Q1 power supply : 727.825
    Right Arm Q1 gauss meter : -0.018352
    Right Arm Q2 power supply current : 416.565
    Right Arm Q2 momentum : 0.96793
    Right Arm Q2 gauss meter : 0.2182
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 330.966
    Right Arm D1 momentum : 0.967944
    Right Arm D1 NMR : 0.359192
    Right Arm Q3 power supply current : 424.167
    Right Arm Q3 momentum : 1.06599
    Right Arm Q3 gauss meter : 0.18956
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 0.0240565
    Current on Unser monitor : 12.6856
    Current on Upstream bcm : 0.0354647
    Current on Downstream bcm : 0.0126483
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 0.0123755
    Hall C Current : 0
    MBSY1c magnet current (amp) : 39.5773
    MBSY1c Bdl : 239056
    Hall A momentum (Tiefenbach) (HALLA:p) : 957.504
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 960
    Hall A energy (halla_MeV) : 957.504
    Hall C energy (hallc_MeV) : 4592.01
    Delta(E)/E width (MV_AI_DXWID) : 1.06893
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Left Arm Collimator : 0.871631
    HacL_HPE1313A:0_Ch58 : -0.14209
    HacL_HPE1313A:0_Ch55 : 23.6816
    HacL_HPE1313A:0_Ch54 : -0.135254
    -----
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.71429
    SLI vert. size mm : 0
    SLI y position : 1.61502
    -----
    Target : Tantalum
    Vacuum Pressure : 4.07361e-07
    fan frequency loop 1 : 0
    fan frequency loop 3 : 35.5
    Encoder position : -72742
    Target type : -72742
    temperature loop 1(1) : 110.43
    temperature loop 1(3) : 96.81
    Heat exchange He : 92.9
    temperature loop 3(1) : 19.36
    temperature loop 3(3) : 19.6
    Heat exchange H2 : 19
    HPH He loop 1 : 0.0813417
    HPH H2 loop 3 : 0.011068