Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name a-onl

    Log entry time 04:53:28 on January 31, 2008

    Entry number 228249

    keyword=End_of_Run_3704
    ****************************
     Run Number: 3704
     End of Run Comment:
    Run_type=Cosmics,target_type=Tantalum,beam_e0=0.956,beam_raster=on,leftarm_p=0.948,leftarm_theta=20.37,leftarm_colli=out,rightarm_p=0.96793,rightarm_theta=19.00,rightarm_colli=out,comment_text=Tantalum, 8 uA, 10 Hz stack triggers
     
    
    PRESCALE FACTORS:ps1=10000   ps2=99999   ps3=9999   ps4=1   ps5=99999   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 18444        
    TIME     : 42.173 mins  
    
    DEAD TIME:   0.21%      
    
    TRIGGER RATES:   PRES/REAL
    T1: 0.1/574.4 Hz   T2: 0.0/161.0 Hz   T3: 0.0/0.0  Hz   T4: 7.2/7.2  Hz   T5: 0.0/0.0  Hz   T6: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:    145/1453458  T2:      4/407373   T3:      0/0        T4:  18296/18296    T5:      0/0        T6:      0/0        T8:     39/2591083  
    
    AVERAGE CURRENT
    BCM x1 : 5.4015 uA  BCM x3 : 5.4036 uA  BCM x10: 5.4471 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.01365        BCM u3 : 0.01365        BCM u10: 0.01375        
    
    BCM d1 : 0.01369        BCM d3 : 0.01369        BCM d10: 0.01381        
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 3704 at Thu Jan 31 04:53:24 EST 2008
    
    Wien angle : -46.0068
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.89998
    Left Arm arm angle : 20.37
    Right Arm D1 momentum : 0.967945
    Right Arm arm angle : 18.9999
    HALLA:p : 957.504
    HALLA:dpp : 0
    Tiefenbach Hall A energy : 957.504
    Left Arm Top VDC Current : 1.9043
    Left Arm Bottom VDC Current : 1.02539
    Left Arm Q1 momentum : 0.899916
    Left Arm Q1 power supply : 677.035
    Left Arm Q1 gauss meter : -0.05719
    Left Arm Q2 gauss meter : 0.15335
    Left Arm Q2 power supply current : 387.526
    Left Arm Q2 momentum : 0.899966
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 298.482
    Left Arm D1 momentum : 0.89998
    Left Arm D1 NMR : 0.333225
    Left Arm Q3 gauss meter : -0.1816
    Left Arm Q3 power supply current : 358.31
    Left Arm Q3 momentum : 0.900008
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.967865
    Right Arm Q1 power supply : 727.771
    Right Arm Q1 gauss meter : -0.018337
    Right Arm Q2 power supply current : 416.566
    Right Arm Q2 momentum : 0.967931
    Right Arm Q2 gauss meter : 0.2182
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 330.966
    Right Arm D1 momentum : 0.967945
    Right Arm D1 NMR : 0.359192
    Right Arm Q3 power supply current : 424.168
    Right Arm Q3 momentum : 1.06599
    Right Arm Q3 gauss meter : 0.18956
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 0.0240128
    Current on Unser monitor : 12.9288
    Current on Upstream bcm : 0.0354327
    Current on Downstream bcm : 0.012593
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 0.0117642
    Hall C Current : 0
    MBSY1c magnet current (amp) : 0.0377198
    MBSY1c Bdl : 239056
    Hall A momentum (Tiefenbach) (HALLA:p) : 957.504
    Hall A momentum orbit correction (dpp) : 0
    Hall A setup momentum (MMSHLAE) : 960
    Hall A energy (halla_MeV) : 957.504
    Hall C energy (hallc_MeV) : 4592.01
    Delta(E)/E width (MV_AI_DXWID) : 1.05879
    IPM1C12.XPOS : 0
    IPM1H04A.XPOS : 0
    IPM1H04A.YPOS : 0
    IPM1H04B.XPOS : 0
    IPM1H04B.YPOS : 0
    Left Arm Collimator : 0.871631
    HacL_HPE1313A:0_Ch58 : -0.142578
    HacL_HPE1313A:0_Ch55 : 23.6816
    HacL_HPE1313A:0_Ch54 : -0.134766
    SLI data valid? : No
    SLI horiz size mm : 0
    SLI Energy spread *10^5 : 0
    SLI x position : 1.71429
    SLI vert. size mm : 0
    SLI y position : 0.751174
    -----
    Target : Tantalum
    fan frequency loop 1 : 0
    fan frequency loop 3 : 36
    Encoder position : -72742
    Target type : -72742
    temperature loop 1(1) : 110.42
    temperature loop 1(3) : 96.7
    Heat exchange He : 92.9
    temperature loop 3(1) : 19.37
    temperature loop 3(3) : 19.6
    Heat exchange H2 : 19
    HPH He loop 1 : 0.0813417
    HPH He loop 2 : 0.00710569
    HPH H2 loop 3 : 0.011068
    -----