Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 06:50:28 on January 31, 2008

    Entry number 228258

    keyword=End_of_Run_6038
    ****************************
     Run Number: 6038
     End of Run Comment:
    Run_type=Production,target_type=Iron 50 degs  Right,beam_e0=0.9574,beam_raster=on,beam_halfwaveplate=out,leftarm_p=0.500,leftarm_theta=20.37,leftarm_colli=out,rightarm_p=0.948,rightarm_theta=19,rightarm_colli=out,comment_text=Ta target Jan-30-2008-100V_f.txt, junk
     
    
    PRESCALE FACTORS:ps1=9999   ps2=9999   ps3=1   ps4=2   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 1783         
    TIME     : 0.126 mins  
    
    DEAD TIME:  58.95%      
    
    TRIGGER RATES:   PRES/REAL
    T1: 0.0/834.6 Hz   T2: 0.0/0.0  Hz   T3:557.8/557.8 Hz   T4:16.3/32.5 Hz   T5: 0.0/0.0  Hz   T6: 0.0/235.7 Hz   T7: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   T9: 0.0/0.0  Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:      0/6314     T2:      0/0        T3:   4220/4220     T4:    123/246      T5:      0/0        T6:      0/1783     T7:      0/0        T8:      0/7747     T9:      0/0        
    
    AVERAGE CURRENT
    BCM x1 : 7.8609 uA  BCM x3 : 7.8689 uA  BCM x10: 7.9106 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 5.947E-05      BCM u3 : 5.947E-05      BCM u10: 5.986E-05      
    
    BCM d1 : 5.947E-05      BCM d3 : 5.959E-05      BCM d10: 5.983E-05      
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 6038 at Thu Jan 31 06:50:25 EST 2008
    
    Wien angle : -46.0068
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.49999
    Left Arm arm angle : 20.37
    Right Arm D1 momentum : 0.967945
    Right Arm arm angle : 18.9999
    HALLA:p : 957.41
    HALLA:dpp : -9.77926e-05
    Tiefenbach Hall A energy : 957.41
    Left Arm Top VDC Current : 2.34375
    Left Arm Bottom VDC Current : 3.85742
    Left Arm Q1 momentum : 0.50004
    Left Arm Q1 power supply : 376.196
    Left Arm Q1 gauss meter : -0.03178
    Left Arm Q2 gauss meter : 0.08553
    Left Arm Q2 power supply current : 215.3
    Left Arm Q2 momentum : 0.5
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 164.748
    Left Arm D1 momentum : 0.49999
    Left Arm D1 NMR : 0.185236
    Left Arm Q3 gauss meter : -0.10095
    Left Arm Q3 power supply current : 199.06
    Left Arm Q3 momentum : 0.500001
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.967865
    Right Arm Q1 power supply : 727.771
    Right Arm Q1 gauss meter : -0.018351
    Right Arm Q2 power supply current : 416.564
    Right Arm Q2 momentum : 0.967926
    Right Arm Q2 gauss meter : 0.2182
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 330.967
    Right Arm D1 momentum : 0.967945
    Right Arm D1 NMR : 0.359193
    Right Arm Q3 power supply current : 424.167
    Right Arm Q3 momentum : 1.06599
    Right Arm Q3 gauss meter : 0.18956
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 7.84526
    Current on Unser monitor : 18.8643
    Current on Upstream bcm : 7.8526
    Current on Downstream bcm : 7.83793
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 7.786
    Hall C Current : 0
    MBSY1c magnet current (amp) : 39.5773
    MBSY1c Bdl : 239056
    Hall A momentum (Tiefenbach) (HALLA:p) : 957.408
    Hall A momentum orbit correction (dpp) : -0.000100412
    Hall A setup momentum (MMSHLAE) : 960
    Hall A energy (halla_MeV) : 957.408
    Hall C energy (hallc_MeV) : 4592.01
    Delta(E)/E width (MV_AI_DXWID) : 1.0491
    IPM1C12.XPOS : 0.00369903
    IPM1H04A.XPOS : 0.00722963
    IPM1H04A.YPOS : 0.934535
    IPM1H04B.XPOS : 0.000644386
    IPM1H04B.YPOS : 1.00522
    Left Arm Collimator : 0.87168
    HacL_HPE1313A:0_Ch58 : -0.143066
    HacL_HPE1313A:0_Ch55 : 23.7305
    HacL_HPE1313A:0_Ch54 : -0.135742
    -----
    SLI data valid? : Yes
    SLI horiz size mm : 0.207628
    SLI Energy spread *10^5 : 5.19069
    SLI x position : 1.5205
    SLI vert. size mm : 0.149716
    SLI y position : 1.53239
    -----
    Target : Tantalum
    Vacuum Pressure : 4.18091e-07
    fan frequency loop 1 : 0
    fan frequency loop 3 : 36
    Encoder position : -72742
    Target type : -72742
    temperature loop 1(1) : 110.45
    temperature loop 1(3) : 96.89
    Heat exchange He : 92.9
    temperature loop 3(1) : 19.35
    temperature loop 3(3) : 19.59
    Heat exchange H2 : 19
    HPH He loop 1 : 0.0813417
    HPH H2 loop 3 : 0.00293052