NEXT
User name adev
Log entry time 07:05:32 on January 31, 2008
Entry number 228261
keyword=End_of_Run_6039
****************************
Run Number: 6039
End of Run Comment:
Run_type=Production,target_type=Iron 50 degs Right,beam_e0=0.9574,beam_raster=on,beam_halfwaveplate=out,leftarm_p=0.500,leftarm_theta=20.37,leftarm_colli=out,rightarm_p=0.948,rightarm_theta=19,rightarm_colli=out,comment_text=Ta target Jan-30-2008-100V_h.txt, stopped due to accidental movemeant ok L-HRS
PRESCALE FACTORS:ps1=9999 ps2=9999 ps3=1 ps4=2 ps5=65535 ps6=65535 ps7=65535 ps8=65535
EVENTS : 122692
TIME : 11.096 mins
DEAD TIME: 67.83%
TRIGGER RATES: PRES/REAL
T1: 0.1/829.5 Hz T2: 0.0/0.0 Hz T3:555.3/555.3 Hz T4:17.5/35.0 Hz T5: 0.0/0.0 Hz T6: 0.0/184.3 Hz T7: 0.0/0.0 Hz T8: 0.0/1024.0 Hz T9: 0.0/0.0 Hz
TRIGGER TOTALS: PRES/REAL
T1: 55/552212 T2: 0/0 T3: 369718/369718 T4: 11644/23288 T5: 0/0 T6: 1/122692 T7: 0/0 T8: 10/681722 T9: 0/0
AVERAGE CURRENT
BCM x1 : 7.8459 uA BCM x3 : 7.8543 uA BCM x10: 7.8953 uA
APPROXIMATE BCM CHARGES (C)
BCM u1 : 0.005223 BCM u3 : 0.005222 BCM u10: 0.005257
BCM d1 : 0.005224 BCM d3 : 0.005236 BCM d10: 0.005256
****************************
End-of-run EPICS data for Run Number 6039 at Thu Jan 31 07:05:28 EST 2008
Wien angle : -46.0068
Half-wave plate (off=out) : IN
Left Arm D1 momentum : 0.499988
Left Arm arm angle : 20.4276
Right Arm D1 momentum : 0.967946
Right Arm arm angle : 18.9999
HALLA:p : 957.407
HALLA:dpp : -0.00010113
Tiefenbach Hall A energy : 957.407
Left Arm Top VDC Current : -1.5625
Left Arm Bottom VDC Current : 2.14844
Left Arm Q1 momentum : 0.50004
Left Arm Q1 power supply : 376.196
Left Arm Q1 gauss meter : -0.03177
Left Arm Q2 gauss meter : 0.08554
Left Arm Q2 power supply current : 215.3
Left Arm Q2 momentum : 0.500002
Left Arm Q2 power supply polarity : disabled
Left Arm D1 power supply current : 164.747
Left Arm D1 momentum : 0.499988
Left Arm D1 NMR : 0.185236
Left Arm Q3 gauss meter : -0.10095
Left Arm Q3 power supply current : 199.059
Left Arm Q3 momentum : 0.5
Left Arm Q3 power supply polarity : disabled
Right Arm Q1 momentum : 0.967936
Right Arm Q1 power supply : 727.825
Right Arm Q1 gauss meter : -0.018355
Right Arm Q2 power supply current : 416.564
Right Arm Q2 momentum : 0.967926
Right Arm Q2 gauss meter : 0.2182
Right Arm Q2 power supply polarity : enabled
Right Arm D1 power supply current : 330.967
Right Arm D1 momentum : 0.967946
Right Arm D1 NMR : 0.359193
Right Arm Q3 power supply current : 424.169
Right Arm Q3 momentum : 1.06599
Right Arm Q3 gauss meter : 0.18956
Right Arm Q3 power supply polarity : disabled
Average current of the two cavities : 8.10832
Current on Unser monitor : 20.283
Current on Upstream bcm : 8.11016
Current on Downstream bcm : 8.10648
Upstream Cavity Coefficient : 43.377
Downstream Cavity Coefficient : 42.913
Current on IBC0L02 (source) : 8.03552
Hall C Current : 0
MBSY1c magnet current (amp) : 39.5773
MBSY1c Bdl : 239056
Hall A momentum (Tiefenbach) (HALLA:p) : 957.409
Hall A momentum orbit correction (dpp) : -9.87252e-05
Hall A setup momentum (MMSHLAE) : 960
Hall A energy (halla_MeV) : 957.41
Hall C energy (hallc_MeV) : 4592.01
Delta(E)/E width (MV_AI_DXWID) : 1.09667
IPM1C12.XPOS : 0.0025726
IPM1H04A.XPOS : 0.0142653
IPM1H04A.YPOS : 0.92476
IPM1H04B.XPOS : -0.00555116
IPM1H04B.YPOS : 0.977266
Left Arm Collimator : 0.871631
HacL_HPE1313A:0_Ch58 : -0.143555
HacL_HPE1313A:0_Ch55 : 23.6816
HacL_HPE1313A:0_Ch54 : -0.137207
-----
SLI data valid? : Yes
SLI horiz size mm : 0.109948
SLI Energy spread *10^5 : 2.74871
SLI x position : 1.51304
SLI vert. size mm : 0.151126
SLI y position : 1.52488
-----
Target : Tantalum
Vacuum Pressure : 4.17651e-07
fan frequency loop 1 : 0
fan frequency loop 3 : 36
Encoder position : -72742
Target type : -72742
temperature loop 1(1) : 110.44
temperature loop 1(3) : 96.71
Heat exchange He : 92.9
temperature loop 3(1) : 19.35
temperature loop 3(3) : 19.59
Heat exchange H2 : 19
HPH He loop 1 : 0.0813417
HPH H2 loop 3 : 0.00634721