Privacy and Security Notice


  • Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name adev

    Log entry time 08:05:40 on January 31, 2008

    Entry number 228271

    keyword=End_of_Run_6041
    ****************************
     Run Number: 6041
     End of Run Comment:
    Run_type=Production,target_type=Iron 50 degs  Right,beam_e0=0.9574,beam_raster=on,beam_halfwaveplate=out,leftarm_p=0.500,leftarm_theta=20.428,leftarm_colli=out,rightarm_p=0.948,rightarm_theta=19,rightarm_colli=out,comment_text=Ta target Jan-30-2008-100V_h.txt
     
    
    PRESCALE FACTORS:ps1=9999   ps2=9999   ps3=1   ps4=2   ps5=65535   ps6=65535   ps7=65535   ps8=65535   
    
    EVENTS   : 255569       
    TIME     : 22.593 mins  
    
    DEAD TIME:  67.42%      
    
    TRIGGER RATES:   PRES/REAL
    T1: 0.5/4703.0 Hz   T2: 0.0/0.0  Hz   T3:559.0/559.0 Hz   T4:19.2/38.4 Hz   T5: 0.0/0.0  Hz   T6: 0.0/188.5 Hz   T7: 0.0/0.0  Hz   T8: 0.0/1024.0 Hz   T9: 0.0/0.0  Hz   
    
    TRIGGER TOTALS:   PRES/REAL
    T1:    637/6375289  T2:      0/0        T3: 757762/757762   T4:  26002/52005    T5:      0/0        T6:      3/255569   T7:      0/0        T8:     21/1388100  T9:      0/0        
    
    AVERAGE CURRENT
    BCM x1 : 7.9166 uA  BCM x3 : 7.9250 uA  BCM x10: 7.9664 uA  
    
    APPROXIMATE BCM CHARGES (C)
    BCM u1 : 0.01072        BCM u3 : 0.01072        BCM u10: 0.01079        
    
    BCM d1 : 0.01074        BCM d3 : 0.01076        BCM d10: 0.0108         
    
    
    
    ****************************
    End-of-run EPICS data for Run Number 6041 at Thu Jan 31 08:05:36 EST 2008
    
    Wien angle : -46.0068
    Half-wave plate (off=out) : IN
    Left Arm D1 momentum : 0.499984
    Left Arm arm angle : 20.4276
    Right Arm D1 momentum : 0.967941
    Right Arm arm angle : 15.9953
    HALLA:p : 957.408
    HALLA:dpp : -0.000100209
    Tiefenbach Hall A energy : 957.408
    Left Arm Top VDC Current : 5.22461
    Left Arm Bottom VDC Current : -1.61133
    Left Arm Q1 momentum : 0.50004
    Left Arm Q1 power supply : 376.196
    Left Arm Q1 gauss meter : -0.03178
    Left Arm Q2 gauss meter : 0.08553
    Left Arm Q2 power supply current : 215.3
    Left Arm Q2 momentum : 0.5
    Left Arm Q2 power supply polarity : disabled
    Left Arm D1 power supply current : 164.745
    Left Arm D1 momentum : 0.499984
    Left Arm D1 NMR : 0.185234
    Left Arm Q3 gauss meter : -0.10095
    Left Arm Q3 power supply current : 199.059
    Left Arm Q3 momentum : 0.5
    Left Arm Q3 power supply polarity : disabled
    Right Arm Q1 momentum : 0.967936
    Right Arm Q1 power supply : 727.771
    Right Arm Q1 gauss meter : -0.018354
    Right Arm Q2 power supply current : 416.563
    Right Arm Q2 momentum : 0.967926
    Right Arm Q2 gauss meter : 0.2182
    Right Arm Q2 power supply polarity : enabled
    Right Arm D1 power supply current : 330.966
    Right Arm D1 momentum : 0.967941
    Right Arm D1 NMR : 0.359191
    Right Arm Q3 power supply current : 424.168
    Right Arm Q3 momentum : 1.06599
    Right Arm Q3 gauss meter : 0.18956
    Right Arm Q3 power supply polarity : disabled
    Average current of the two cavities : 7.93125
    Current on Unser monitor : 19.3794
    Current on Upstream bcm : 7.9325
    Current on Downstream bcm : 7.93
    Upstream Cavity Coefficient : 43.377
    Downstream Cavity Coefficient : 42.913
    Current on IBC0L02 (source) : 7.86437
    Hall C Current : 0
    MBSY1c magnet current (amp) : 39.5773
    MBSY1c Bdl : 239056
    Hall A momentum (Tiefenbach) (HALLA:p) : 957.412
    Hall A momentum orbit correction (dpp) : -9.58645e-05
    Hall A setup momentum (MMSHLAE) : 960
    Hall A energy (halla_MeV) : 957.412
    Hall C energy (hallc_MeV) : 4592.01
    Delta(E)/E width (MV_AI_DXWID) : 1.13558
    IPM1C12.XPOS : -0.00228441
    IPM1H04A.XPOS : 0.0107277
    IPM1H04A.YPOS : 0.906955
    IPM1H04B.XPOS : 0.00134641
    IPM1H04B.YPOS : 0.967017
    Left Arm Collimator : 0.871631
    HacL_HPE1313A:0_Ch58 : -0.139648
    HacL_HPE1313A:0_Ch55 : 23.6816
    HacL_HPE1313A:0_Ch54 : -0.145508
    -----
    SLI data valid? : Yes
    SLI horiz size mm : 0.161273
    SLI Energy spread *10^5 : 4.03183
    SLI x position : 1.49068
    SLI vert. size mm : 0.227584
    SLI y position : 1.52488
    -----
    Target : Tantalum
    Vacuum Pressure : 4.16478e-07
    fan frequency loop 1 : 0
    fan frequency loop 3 : 35.5
    Encoder position : -72742
    Target type : -72742
    temperature loop 1(1) : 110.46
    temperature loop 1(3) : 96.76
    Heat exchange He : 92.9
    temperature loop 3(1) : 19.34
    temperature loop 3(3) : 19.58
    Heat exchange H2 : 19
    HPH He loop 1 : 0.0813417
    HPH H2 loop 3 : 0.011068